Cargando…

Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator

An Image-Guided Radiotherapy–capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Muralidhar, K. R., Murthy, P. Narayana, Kumar, Rajneesh
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772033/
https://www.ncbi.nlm.nih.gov/pubmed/19893694
http://dx.doi.org/10.4103/0971-6203.41276
_version_ 1782173797730746368
author Muralidhar, K. R.
Murthy, P. Narayana
Kumar, Rajneesh
author_facet Muralidhar, K. R.
Murthy, P. Narayana
Kumar, Rajneesh
author_sort Muralidhar, K. R.
collection PubMed
description An Image-Guided Radiotherapy–capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer's specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality). These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy.
format Text
id pubmed-2772033
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27720332009-11-05 Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator Muralidhar, K. R. Murthy, P. Narayana Kumar, Rajneesh J Med Phys Technical Note An Image-Guided Radiotherapy–capable linear accelerator (Elekta Synergy) was installed at our hospital, which is equipped with a kV x-ray volume imaging (XVI) system and electronic portal imaging device (iViewGT). The objective of this presentation is to describe the results of commissioning measurements carried out on the XVI facility to verify the manufacturer's specifications and also to evolve a QA schedule which can be used to test its performance routinely. The QA program consists of a series of tests (safety features, geometric accuracy, and image quality). These tests were found to be useful to assess the performance of the XVI system and also proved that XVI system is very suitable for image-guided high-precision radiation therapy. Medknow Publications 2008 /pmc/articles/PMC2772033/ /pubmed/19893694 http://dx.doi.org/10.4103/0971-6203.41276 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Muralidhar, K. R.
Murthy, P. Narayana
Kumar, Rajneesh
Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title_full Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title_fullStr Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title_full_unstemmed Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title_short Commissioning and quality assurance of the X-ray volume Imaging system of an image-guided radiotherapy capable linear accelerator
title_sort commissioning and quality assurance of the x-ray volume imaging system of an image-guided radiotherapy capable linear accelerator
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772033/
https://www.ncbi.nlm.nih.gov/pubmed/19893694
http://dx.doi.org/10.4103/0971-6203.41276
work_keys_str_mv AT muralidharkr commissioningandqualityassuranceofthexrayvolumeimagingsystemofanimageguidedradiotherapycapablelinearaccelerator
AT murthypnarayana commissioningandqualityassuranceofthexrayvolumeimagingsystemofanimageguidedradiotherapycapablelinearaccelerator
AT kumarrajneesh commissioningandqualityassuranceofthexrayvolumeimagingsystemofanimageguidedradiotherapycapablelinearaccelerator