Design of mini phantom and measurement of cobalt-60 beam data parameters
Low cost mini phantoms were fabricated indigenously with different water equivalent material such as polymethyl methacrylate and Bee's wax of different shapes (with dome top surface and flat top surface). The beam parameters of the Co-60 machine, such as head scatter correction factor (S(h)), p...
Autores principales: | , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772034/ https://www.ncbi.nlm.nih.gov/pubmed/19893699 http://dx.doi.org/10.4103/0971-6203.42750 |
_version_ | 1782173797971918848 |
---|---|
author | Senthilkumar, S. Ramakrishnan, V. |
author_facet | Senthilkumar, S. Ramakrishnan, V. |
author_sort | Senthilkumar, S. |
collection | PubMed |
description | Low cost mini phantoms were fabricated indigenously with different water equivalent material such as polymethyl methacrylate and Bee's wax of different shapes (with dome top surface and flat top surface). The beam parameters of the Co-60 machine, such as head scatter correction factor (S(h)), phantom scatter correction factor (S(P)), total scatter correction factor (S(C,P)), collimator exchange effect were measured. Output ratio measurements were taken for both mini phantom and water phantom for different square and rectangular field sizes. Normalized output ratios were compared with ESTRO published values and (Storchi and Van Gasteren) S and G data. The percentage of variation between the measured and the literature values is about 0.7%. Collimator exchange effect were measured for water and mini phantom for different field size, were compared with ESTRO value. This was found to be 0.5% and 1.0% respectively. Phantom scatter correction factors were calculated for square and rectangular filed sizes; this was compared with ESTRO values, found to be 0.7% for square and 1.0% for rectangular filed size. It was also noted that there were no appreciable variation observed in ion chamber readings of different materials of mini phantoms for dome and flat surfaces. Mini phantom measurements were done for all types of phantoms and the measured values were compared with the existing data and they were in good agreement with the published values. |
format | Text |
id | pubmed-2772034 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-27720342009-11-05 Design of mini phantom and measurement of cobalt-60 beam data parameters Senthilkumar, S. Ramakrishnan, V. J Med Phys Review Article Low cost mini phantoms were fabricated indigenously with different water equivalent material such as polymethyl methacrylate and Bee's wax of different shapes (with dome top surface and flat top surface). The beam parameters of the Co-60 machine, such as head scatter correction factor (S(h)), phantom scatter correction factor (S(P)), total scatter correction factor (S(C,P)), collimator exchange effect were measured. Output ratio measurements were taken for both mini phantom and water phantom for different square and rectangular field sizes. Normalized output ratios were compared with ESTRO published values and (Storchi and Van Gasteren) S and G data. The percentage of variation between the measured and the literature values is about 0.7%. Collimator exchange effect were measured for water and mini phantom for different field size, were compared with ESTRO value. This was found to be 0.5% and 1.0% respectively. Phantom scatter correction factors were calculated for square and rectangular filed sizes; this was compared with ESTRO values, found to be 0.7% for square and 1.0% for rectangular filed size. It was also noted that there were no appreciable variation observed in ion chamber readings of different materials of mini phantoms for dome and flat surfaces. Mini phantom measurements were done for all types of phantoms and the measured values were compared with the existing data and they were in good agreement with the published values. Medknow Publications 2008 /pmc/articles/PMC2772034/ /pubmed/19893699 http://dx.doi.org/10.4103/0971-6203.42750 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Senthilkumar, S. Ramakrishnan, V. Design of mini phantom and measurement of cobalt-60 beam data parameters |
title | Design of mini phantom and measurement of cobalt-60 beam data parameters |
title_full | Design of mini phantom and measurement of cobalt-60 beam data parameters |
title_fullStr | Design of mini phantom and measurement of cobalt-60 beam data parameters |
title_full_unstemmed | Design of mini phantom and measurement of cobalt-60 beam data parameters |
title_short | Design of mini phantom and measurement of cobalt-60 beam data parameters |
title_sort | design of mini phantom and measurement of cobalt-60 beam data parameters |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2772034/ https://www.ncbi.nlm.nih.gov/pubmed/19893699 http://dx.doi.org/10.4103/0971-6203.42750 |
work_keys_str_mv | AT senthilkumars designofminiphantomandmeasurementofcobalt60beamdataparameters AT ramakrishnanv designofminiphantomandmeasurementofcobalt60beamdataparameters |