Cargando…

Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments

BACKGROUND: In the present work we compared the spatial uncertainties associated with a MR-based workflow for external radiotherapy of prostate cancer to a standard CT-based workflow. The MR-based workflow relies on target definition and patient positioning based on MR imaging. A solution for patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Nyholm, Tufve, Nyberg, Morgan, Karlsson, Magnus G, Karlsson, Mikael
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2781017/
https://www.ncbi.nlm.nih.gov/pubmed/19919713
http://dx.doi.org/10.1186/1748-717X-4-54
_version_ 1782174552905744384
author Nyholm, Tufve
Nyberg, Morgan
Karlsson, Magnus G
Karlsson, Mikael
author_facet Nyholm, Tufve
Nyberg, Morgan
Karlsson, Magnus G
Karlsson, Mikael
author_sort Nyholm, Tufve
collection PubMed
description BACKGROUND: In the present work we compared the spatial uncertainties associated with a MR-based workflow for external radiotherapy of prostate cancer to a standard CT-based workflow. The MR-based workflow relies on target definition and patient positioning based on MR imaging. A solution for patient transport between the MR scanner and the treatment units has been developed. For the CT-based workflow, the target is defined on a MR series but then transferred to a CT study through image registration before treatment planning, and a patient positioning using portal imaging and fiducial markers. METHODS: An "open bore" 1.5T MRI scanner, Siemens Espree, has been installed in the radiotherapy department in near proximity to a treatment unit to enable patient transport between the two installations, and hence use the MRI for patient positioning. The spatial uncertainty caused by the transport was added to the uncertainty originating from the target definition process, estimated through a review of the scientific literature. The uncertainty in the CT-based workflow was estimated through a literature review. RESULTS: The systematic uncertainties, affecting all treatment fractions, are reduced from 3-4 mm (1Sd) with a CT based workflow to 2-3 mm with a MR based workflow. The main contributing factor to this improvement is the exclusion of registration between MR and CT in the planning phase of the treatment. CONCLUSION: Treatment planning directly on MR images reduce the spatial uncertainty for prostate treatments.
format Text
id pubmed-2781017
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27810172009-11-24 Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments Nyholm, Tufve Nyberg, Morgan Karlsson, Magnus G Karlsson, Mikael Radiat Oncol Research BACKGROUND: In the present work we compared the spatial uncertainties associated with a MR-based workflow for external radiotherapy of prostate cancer to a standard CT-based workflow. The MR-based workflow relies on target definition and patient positioning based on MR imaging. A solution for patient transport between the MR scanner and the treatment units has been developed. For the CT-based workflow, the target is defined on a MR series but then transferred to a CT study through image registration before treatment planning, and a patient positioning using portal imaging and fiducial markers. METHODS: An "open bore" 1.5T MRI scanner, Siemens Espree, has been installed in the radiotherapy department in near proximity to a treatment unit to enable patient transport between the two installations, and hence use the MRI for patient positioning. The spatial uncertainty caused by the transport was added to the uncertainty originating from the target definition process, estimated through a review of the scientific literature. The uncertainty in the CT-based workflow was estimated through a literature review. RESULTS: The systematic uncertainties, affecting all treatment fractions, are reduced from 3-4 mm (1Sd) with a CT based workflow to 2-3 mm with a MR based workflow. The main contributing factor to this improvement is the exclusion of registration between MR and CT in the planning phase of the treatment. CONCLUSION: Treatment planning directly on MR images reduce the spatial uncertainty for prostate treatments. BioMed Central 2009-11-17 /pmc/articles/PMC2781017/ /pubmed/19919713 http://dx.doi.org/10.1186/1748-717X-4-54 Text en Copyright ©2009 Nyholm et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Nyholm, Tufve
Nyberg, Morgan
Karlsson, Magnus G
Karlsson, Mikael
Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title_full Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title_fullStr Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title_full_unstemmed Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title_short Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatments
title_sort systematisation of spatial uncertainties for comparison between a mr and a ct-based radiotherapy workflow for prostate treatments
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2781017/
https://www.ncbi.nlm.nih.gov/pubmed/19919713
http://dx.doi.org/10.1186/1748-717X-4-54
work_keys_str_mv AT nyholmtufve systematisationofspatialuncertaintiesforcomparisonbetweenamrandactbasedradiotherapyworkflowforprostatetreatments
AT nybergmorgan systematisationofspatialuncertaintiesforcomparisonbetweenamrandactbasedradiotherapyworkflowforprostatetreatments
AT karlssonmagnusg systematisationofspatialuncertaintiesforcomparisonbetweenamrandactbasedradiotherapyworkflowforprostatetreatments
AT karlssonmikael systematisationofspatialuncertaintiesforcomparisonbetweenamrandactbasedradiotherapyworkflowforprostatetreatments