Cargando…

Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy

We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jae-Kwan, Oh, Min-Jeong, Shin, Joong-Sik, Lee, Kyung-Joo, Nam, Jung-Hyun, Cha, Jung-Hak, Chang, Jin-Dong, Cho, Dong-Hee, Kang, In-Soo, Lee, Paul I
Formato: Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2005
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2782204/
https://www.ncbi.nlm.nih.gov/pubmed/15953870
http://dx.doi.org/10.3346/jkms.2005.20.3.461
_version_ 1782174624258195456
author Lee, Jae-Kwan
Oh, Min-Jeong
Shin, Joong-Sik
Lee, Kyung-Joo
Nam, Jung-Hyun
Cha, Jung-Hak
Chang, Jin-Dong
Cho, Dong-Hee
Kang, In-Soo
Lee, Paul I
author_facet Lee, Jae-Kwan
Oh, Min-Jeong
Shin, Joong-Sik
Lee, Kyung-Joo
Nam, Jung-Hyun
Cha, Jung-Hak
Chang, Jin-Dong
Cho, Dong-Hee
Kang, In-Soo
Lee, Paul I
author_sort Lee, Jae-Kwan
collection PubMed
description We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic pregnancy. This study included 40 normal pregnant women and 25 patients with ectopic pregnancy. Patients' serum and urinary intact whole hCG (i-hCG) and hCGRP concentrations were measured using sandwich ELISA and the ratio of hCGRP to i-hCG was calculated. Statistical analysis was performed using statistical package for social sciences (SPSS) 10.0. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the cut-off value to discriminate ectopic pregnancies from normal intrauterine pregnancies. Urinary hCGRP and hCGRP/i-hCG ratio in ectopic pregnancy group (14±6.6 ng/mL, 4.6±1.9%, respectively) were significantly lower than those of normal pregnancy group (149±10.2 ng/mL, 29.7±1.9%, respectively; p<0.001). Based on ROC curve analysis, a cut-off point of urinary hCGRP/i-hCG ratio <16.2% discriminated between ectopic pregnancy and normal pregnancy with a sensitivity, specificity, positive predictive value and negative predictive value of 92.0%, 90.0%, 32.6%, and 99.5%, respectively. Urinary hCGRP/i-hCG ratio measurement may be effective in diagnosing ectopic pregnancy.
format Text
id pubmed-2782204
institution National Center for Biotechnology Information
language English
publishDate 2005
publisher The Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-27822042009-11-30 Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy Lee, Jae-Kwan Oh, Min-Jeong Shin, Joong-Sik Lee, Kyung-Joo Nam, Jung-Hyun Cha, Jung-Hak Chang, Jin-Dong Cho, Dong-Hee Kang, In-Soo Lee, Paul I J Korean Med Sci Original Article We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic pregnancy. This study included 40 normal pregnant women and 25 patients with ectopic pregnancy. Patients' serum and urinary intact whole hCG (i-hCG) and hCGRP concentrations were measured using sandwich ELISA and the ratio of hCGRP to i-hCG was calculated. Statistical analysis was performed using statistical package for social sciences (SPSS) 10.0. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the cut-off value to discriminate ectopic pregnancies from normal intrauterine pregnancies. Urinary hCGRP and hCGRP/i-hCG ratio in ectopic pregnancy group (14±6.6 ng/mL, 4.6±1.9%, respectively) were significantly lower than those of normal pregnancy group (149±10.2 ng/mL, 29.7±1.9%, respectively; p<0.001). Based on ROC curve analysis, a cut-off point of urinary hCGRP/i-hCG ratio <16.2% discriminated between ectopic pregnancy and normal pregnancy with a sensitivity, specificity, positive predictive value and negative predictive value of 92.0%, 90.0%, 32.6%, and 99.5%, respectively. Urinary hCGRP/i-hCG ratio measurement may be effective in diagnosing ectopic pregnancy. The Korean Academy of Medical Sciences 2005-06 2005-06-30 /pmc/articles/PMC2782204/ /pubmed/15953870 http://dx.doi.org/10.3346/jkms.2005.20.3.461 Text en Copyright © 2005 The Korean Academy of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jae-Kwan
Oh, Min-Jeong
Shin, Joong-Sik
Lee, Kyung-Joo
Nam, Jung-Hyun
Cha, Jung-Hak
Chang, Jin-Dong
Cho, Dong-Hee
Kang, In-Soo
Lee, Paul I
Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title_full Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title_fullStr Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title_full_unstemmed Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title_short Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
title_sort clinical effectiveness of urinary human chorionic gonadotropin related protein (hcgrp) quantification for diagnosis of ectopic pregnancy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2782204/
https://www.ncbi.nlm.nih.gov/pubmed/15953870
http://dx.doi.org/10.3346/jkms.2005.20.3.461
work_keys_str_mv AT leejaekwan clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT ohminjeong clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT shinjoongsik clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT leekyungjoo clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT namjunghyun clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT chajunghak clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT changjindong clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT chodonghee clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT kanginsoo clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy
AT leepauli clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy