Cargando…
Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy
We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Medical Sciences
2005
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2782204/ https://www.ncbi.nlm.nih.gov/pubmed/15953870 http://dx.doi.org/10.3346/jkms.2005.20.3.461 |
_version_ | 1782174624258195456 |
---|---|
author | Lee, Jae-Kwan Oh, Min-Jeong Shin, Joong-Sik Lee, Kyung-Joo Nam, Jung-Hyun Cha, Jung-Hak Chang, Jin-Dong Cho, Dong-Hee Kang, In-Soo Lee, Paul I |
author_facet | Lee, Jae-Kwan Oh, Min-Jeong Shin, Joong-Sik Lee, Kyung-Joo Nam, Jung-Hyun Cha, Jung-Hak Chang, Jin-Dong Cho, Dong-Hee Kang, In-Soo Lee, Paul I |
author_sort | Lee, Jae-Kwan |
collection | PubMed |
description | We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic pregnancy. This study included 40 normal pregnant women and 25 patients with ectopic pregnancy. Patients' serum and urinary intact whole hCG (i-hCG) and hCGRP concentrations were measured using sandwich ELISA and the ratio of hCGRP to i-hCG was calculated. Statistical analysis was performed using statistical package for social sciences (SPSS) 10.0. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the cut-off value to discriminate ectopic pregnancies from normal intrauterine pregnancies. Urinary hCGRP and hCGRP/i-hCG ratio in ectopic pregnancy group (14±6.6 ng/mL, 4.6±1.9%, respectively) were significantly lower than those of normal pregnancy group (149±10.2 ng/mL, 29.7±1.9%, respectively; p<0.001). Based on ROC curve analysis, a cut-off point of urinary hCGRP/i-hCG ratio <16.2% discriminated between ectopic pregnancy and normal pregnancy with a sensitivity, specificity, positive predictive value and negative predictive value of 92.0%, 90.0%, 32.6%, and 99.5%, respectively. Urinary hCGRP/i-hCG ratio measurement may be effective in diagnosing ectopic pregnancy. |
format | Text |
id | pubmed-2782204 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2005 |
publisher | The Korean Academy of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-27822042009-11-30 Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy Lee, Jae-Kwan Oh, Min-Jeong Shin, Joong-Sik Lee, Kyung-Joo Nam, Jung-Hyun Cha, Jung-Hak Chang, Jin-Dong Cho, Dong-Hee Kang, In-Soo Lee, Paul I J Korean Med Sci Original Article We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic pregnancy. This study included 40 normal pregnant women and 25 patients with ectopic pregnancy. Patients' serum and urinary intact whole hCG (i-hCG) and hCGRP concentrations were measured using sandwich ELISA and the ratio of hCGRP to i-hCG was calculated. Statistical analysis was performed using statistical package for social sciences (SPSS) 10.0. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the cut-off value to discriminate ectopic pregnancies from normal intrauterine pregnancies. Urinary hCGRP and hCGRP/i-hCG ratio in ectopic pregnancy group (14±6.6 ng/mL, 4.6±1.9%, respectively) were significantly lower than those of normal pregnancy group (149±10.2 ng/mL, 29.7±1.9%, respectively; p<0.001). Based on ROC curve analysis, a cut-off point of urinary hCGRP/i-hCG ratio <16.2% discriminated between ectopic pregnancy and normal pregnancy with a sensitivity, specificity, positive predictive value and negative predictive value of 92.0%, 90.0%, 32.6%, and 99.5%, respectively. Urinary hCGRP/i-hCG ratio measurement may be effective in diagnosing ectopic pregnancy. The Korean Academy of Medical Sciences 2005-06 2005-06-30 /pmc/articles/PMC2782204/ /pubmed/15953870 http://dx.doi.org/10.3346/jkms.2005.20.3.461 Text en Copyright © 2005 The Korean Academy of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jae-Kwan Oh, Min-Jeong Shin, Joong-Sik Lee, Kyung-Joo Nam, Jung-Hyun Cha, Jung-Hak Chang, Jin-Dong Cho, Dong-Hee Kang, In-Soo Lee, Paul I Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title | Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title_full | Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title_fullStr | Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title_full_unstemmed | Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title_short | Clinical Effectiveness of Urinary Human Chorionic Gonadotropin Related Protein (hCGRP) Quantification for Diagnosis of Ectopic Pregnancy |
title_sort | clinical effectiveness of urinary human chorionic gonadotropin related protein (hcgrp) quantification for diagnosis of ectopic pregnancy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2782204/ https://www.ncbi.nlm.nih.gov/pubmed/15953870 http://dx.doi.org/10.3346/jkms.2005.20.3.461 |
work_keys_str_mv | AT leejaekwan clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT ohminjeong clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT shinjoongsik clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT leekyungjoo clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT namjunghyun clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT chajunghak clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT changjindong clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT chodonghee clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT kanginsoo clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy AT leepauli clinicaleffectivenessofurinaryhumanchorionicgonadotropinrelatedproteinhcgrpquantificationfordiagnosisofectopicpregnancy |