Cargando…

Methemoglobinemia in critically ill patients during extended hemodialysis and simultaneous disinfection of the hospital water supply

INTRODUCTION: To evaluate the cause of methemoglobinemia in patients undergoing extended daily hemodialysis/hemodiafiltration we analyzed the relationship between methemoglobinemia and the water disinfection schedule of the hospital. METHODS: We reviewed all arterial blood gas analyses, obtained ove...

Descripción completa

Detalles Bibliográficos
Autores principales: Bek, Martin Johannes, Laule, Sven, Reichert-Jünger, Christine, Holtkamp, Rainer, Wiesner, Michael, Keyl, Cornelius
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784392/
https://www.ncbi.nlm.nih.gov/pubmed/19821985
http://dx.doi.org/10.1186/cc8128
Descripción
Sumario:INTRODUCTION: To evaluate the cause of methemoglobinemia in patients undergoing extended daily hemodialysis/hemodiafiltration we analyzed the relationship between methemoglobinemia and the water disinfection schedule of the hospital. METHODS: We reviewed all arterial blood gas analyses, obtained over a one-year period, in patients undergoing extended hemodialysis/hemodiafiltration, and compared the methemoglobin concentrations obtained on the days when the water supply was disinfected, using a hydrogen peroxide/silver ion preparation, with data measured on disinfection-free days. RESULTS: The evaluation of 706 measurements revealed a maximum methemoglobin fraction of 1.0 (0.8; 1.2) % (median and 25(th); 75(th )percentiles) during hemodialysis/hemodiafiltration on the disinfection-free days. The methemoglobin fraction increased to 5.9 (1.3; 8.4) % with a maximal value of 12.2% on the days of water disinfection (P < 0.001 compared to disinfection-free days). Spot checks on hydrogen peroxide concentrations in the water supply, the permeate, and the dialysate, using a semi-quantitative test, demonstrated levels between 10 and 25 mg/l during water disinfection. CONCLUSIONS: Our results demonstrate that even a regular hospital water disinfection technique can be associated with significant methemoglobinemia during extended hemodialysis. Clinicians should be aware of this potential hazard.