Cargando…

Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time

INTRODUCTION: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to f...

Descripción completa

Detalles Bibliográficos
Autores principales: Juneja, Rattan, Roudebush, Corbin P, Nasraway, Stanley A, Golas, Adam A, Jacobi, Judith, Carroll, Joni, Nelson, Deborah, Abad, Victor J, Flanders, Samuel J
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784393/
https://www.ncbi.nlm.nih.gov/pubmed/19822000
http://dx.doi.org/10.1186/cc8129
_version_ 1782174739981139968
author Juneja, Rattan
Roudebush, Corbin P
Nasraway, Stanley A
Golas, Adam A
Jacobi, Judith
Carroll, Joni
Nelson, Deborah
Abad, Victor J
Flanders, Samuel J
author_facet Juneja, Rattan
Roudebush, Corbin P
Nasraway, Stanley A
Golas, Adam A
Jacobi, Judith
Carroll, Joni
Nelson, Deborah
Abad, Victor J
Flanders, Samuel J
author_sort Juneja, Rattan
collection PubMed
description INTRODUCTION: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to frequency and conditions surrounding hypoglycemic events. METHODS: This is a retrospective analysis of adult patients with hyperglycemia receiving intravenous (IV) insulin therapy from March 2006 to December 2007 in the intensive care units of 2 tertiary care teaching hospitals. Patients placed on a glycemic control protocol using the Clarian GlucoStabilizer™ IV insulin dosing calculator with a target range of 4.4-6.1 mmol/L were analyzed. Metrics included time to target, time in target, mean blood glucose ± standard deviation, % measures in hypoglycemic ranges <3.9 mmol/L, per-patient hypoglycemia, and BG testing interval. RESULTS: 4,588 ICU patients were treated with the GlucoStabilizer to a BG target range of 4.4-6.1 mmol/L. We observed 254 severe hypoglycemia episodes (BG <2.2 mmol/L) in 195 patients, representing 0.1% of all measurements, and in 4.25% of patients or 0.6 episodes per 1000 hours on insulin infusion. The most common contributing cause for hypoglycemia was measurement delay (n = 170, 66.9%). The median (interquartile range) time to achieve the target range was 5.9 (3.8 - 8.9) hours. Nearly all (97.5%) of patients achieved target and remained in target 73.4% of the time. The mean BG (± SD) after achieving target was 5.4 (± 0.52) mmol/L. Targeted blood glucose levels were achieved at similar rates with low incidence of severe hypoglycemia in patients with and without diabetes, sepsis, renal, and cardiovascular disease. CONCLUSIONS: Glycemic control to a lower glucose target range can be achieved using a computerized insulin dosing protocol. With particular attention to timely measurement and adjustment of insulin doses the risk of hypoglycemia experienced can be minimized.
format Text
id pubmed-2784393
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27843932009-11-27 Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time Juneja, Rattan Roudebush, Corbin P Nasraway, Stanley A Golas, Adam A Jacobi, Judith Carroll, Joni Nelson, Deborah Abad, Victor J Flanders, Samuel J Crit Care Research INTRODUCTION: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to frequency and conditions surrounding hypoglycemic events. METHODS: This is a retrospective analysis of adult patients with hyperglycemia receiving intravenous (IV) insulin therapy from March 2006 to December 2007 in the intensive care units of 2 tertiary care teaching hospitals. Patients placed on a glycemic control protocol using the Clarian GlucoStabilizer™ IV insulin dosing calculator with a target range of 4.4-6.1 mmol/L were analyzed. Metrics included time to target, time in target, mean blood glucose ± standard deviation, % measures in hypoglycemic ranges <3.9 mmol/L, per-patient hypoglycemia, and BG testing interval. RESULTS: 4,588 ICU patients were treated with the GlucoStabilizer to a BG target range of 4.4-6.1 mmol/L. We observed 254 severe hypoglycemia episodes (BG <2.2 mmol/L) in 195 patients, representing 0.1% of all measurements, and in 4.25% of patients or 0.6 episodes per 1000 hours on insulin infusion. The most common contributing cause for hypoglycemia was measurement delay (n = 170, 66.9%). The median (interquartile range) time to achieve the target range was 5.9 (3.8 - 8.9) hours. Nearly all (97.5%) of patients achieved target and remained in target 73.4% of the time. The mean BG (± SD) after achieving target was 5.4 (± 0.52) mmol/L. Targeted blood glucose levels were achieved at similar rates with low incidence of severe hypoglycemia in patients with and without diabetes, sepsis, renal, and cardiovascular disease. CONCLUSIONS: Glycemic control to a lower glucose target range can be achieved using a computerized insulin dosing protocol. With particular attention to timely measurement and adjustment of insulin doses the risk of hypoglycemia experienced can be minimized. BioMed Central 2009 2009-10-12 /pmc/articles/PMC2784393/ /pubmed/19822000 http://dx.doi.org/10.1186/cc8129 Text en Copyright ©2009 Juneja et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Juneja, Rattan
Roudebush, Corbin P
Nasraway, Stanley A
Golas, Adam A
Jacobi, Judith
Carroll, Joni
Nelson, Deborah
Abad, Victor J
Flanders, Samuel J
Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title_full Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title_fullStr Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title_full_unstemmed Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title_short Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
title_sort computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784393/
https://www.ncbi.nlm.nih.gov/pubmed/19822000
http://dx.doi.org/10.1186/cc8129
work_keys_str_mv AT junejarattan computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT roudebushcorbinp computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT nasrawaystanleya computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT golasadama computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT jacobijudith computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT carrolljoni computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT nelsondeborah computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT abadvictorj computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime
AT flanderssamuelj computerizedintensiveinsulindosingcanmitigatehypoglycemiaandachievetightglycemiccontrolwhenglucosemeasurementisperformedfrequentlyandontime