Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

BACKGROUND: Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sec...

Descripción completa

Detalles Bibliográficos
Autores principales: Hing, Wayne A, Rome, Keith, Cameron, Alyse FM
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784754/
https://www.ncbi.nlm.nih.gov/pubmed/19917127
http://dx.doi.org/10.1186/1757-1146-2-33
_version_ 1782174777432080384
author Hing, Wayne A
Rome, Keith
Cameron, Alyse FM
author_facet Hing, Wayne A
Rome, Keith
Cameron, Alyse FM
author_sort Hing, Wayne A
collection PubMed
description BACKGROUND: Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. METHODS: The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM) calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD) was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. RESULTS: The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. CONCLUSION: The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.
format Text
id pubmed-2784754
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27847542009-11-28 Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines Hing, Wayne A Rome, Keith Cameron, Alyse FM J Foot Ankle Res Methodology article BACKGROUND: Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. METHODS: The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM) calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD) was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. RESULTS: The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. CONCLUSION: The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high. BioMed Central 2009-11-16 /pmc/articles/PMC2784754/ /pubmed/19917127 http://dx.doi.org/10.1186/1757-1146-2-33 Text en Copyright ©2009 Hing et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology article
Hing, Wayne A
Rome, Keith
Cameron, Alyse FM
Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title_full Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title_fullStr Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title_full_unstemmed Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title_short Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
title_sort reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines
topic Methodology article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2784754/
https://www.ncbi.nlm.nih.gov/pubmed/19917127
http://dx.doi.org/10.1186/1757-1146-2-33
work_keys_str_mv AT hingwaynea reliabilityofmeasuringabductorhallucismuscleparametersusingtwodifferentdiagnosticultrasoundmachines
AT romekeith reliabilityofmeasuringabductorhallucismuscleparametersusingtwodifferentdiagnosticultrasoundmachines
AT cameronalysefm reliabilityofmeasuringabductorhallucismuscleparametersusingtwodifferentdiagnosticultrasoundmachines