Solid water phantom heat conduction: Heating and cooling rates

Solid water is often the phantom material of choice for dosimetry procedures in radiotherapy high-energy X-ray and electron beam radiation calibration and quality assurance. This note investigates variation in heat conduction that can occur for a common commercially available solid water stack phant...

Descripción completa

Detalles Bibliográficos
Autores principales: Butson, Martin J., Cheung, Tsang, Yu, Peter K. N.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2786094/
https://www.ncbi.nlm.nih.gov/pubmed/20041049
http://dx.doi.org/10.4103/0971-6203.39421
_version_ 1782174857999417344
author Butson, Martin J.
Cheung, Tsang
Yu, Peter K. N.
author_facet Butson, Martin J.
Cheung, Tsang
Yu, Peter K. N.
author_sort Butson, Martin J.
collection PubMed
description Solid water is often the phantom material of choice for dosimetry procedures in radiotherapy high-energy X-ray and electron beam radiation calibration and quality assurance. This note investigates variation in heat conduction that can occur for a common commercially available solid water stack phantom when a temperature differential occurs between the phantom and ambient temperature. These variations in temperature can then affect radiation measurements and thus the accuracy of radiation dosimetry. In this manuscript, we aim to investigate the variations in temperature which can occur in radiation measurement incorporated (RMI) solid water phantoms, their thermal properties and the effects on radiation dosimetry which can occur because of temperature differentials. Results have shown that the rate of temperature change at a phantom center is a complex function but appears relatively proportional to the surface area of the phantom in normal clinical usage. It is also dependent on the thermal conductivity of any material in contact with the phantom; and the nature of the phantom construction, i.e., the number and thickness of slices within the phantom. A thermal time constant of approximately 20 min was measured for a 2-cm solid water phantom slice when located on a steel workbench in comparison to 60 min when located on a wooden workbench (linac couch insert). It is found that for larger solid water stack phantoms, a transient (within 1°C) thermal equilibrium exists at the center for up to 2 h, before the temperature begins to change. This is assumed to be due to the insulating properties of multiple slices within the stack, whereby very small air spaces are introduced inhibiting the heat conduction through the phantom material. It is therefore recommended that the solid water/phantom material is kept within the treatment room for closest thermal accuracy conditions or at least placed within the room approximately 10 h before dosimetry measurements. If these options are not available, a standard linear interpolation method for calculation of temperature should be used to minimize uncertainty of temperature measurements.
format Text
id pubmed-2786094
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27860942009-12-29 Solid water phantom heat conduction: Heating and cooling rates Butson, Martin J. Cheung, Tsang Yu, Peter K. N. J Med Phys Technical Note Solid water is often the phantom material of choice for dosimetry procedures in radiotherapy high-energy X-ray and electron beam radiation calibration and quality assurance. This note investigates variation in heat conduction that can occur for a common commercially available solid water stack phantom when a temperature differential occurs between the phantom and ambient temperature. These variations in temperature can then affect radiation measurements and thus the accuracy of radiation dosimetry. In this manuscript, we aim to investigate the variations in temperature which can occur in radiation measurement incorporated (RMI) solid water phantoms, their thermal properties and the effects on radiation dosimetry which can occur because of temperature differentials. Results have shown that the rate of temperature change at a phantom center is a complex function but appears relatively proportional to the surface area of the phantom in normal clinical usage. It is also dependent on the thermal conductivity of any material in contact with the phantom; and the nature of the phantom construction, i.e., the number and thickness of slices within the phantom. A thermal time constant of approximately 20 min was measured for a 2-cm solid water phantom slice when located on a steel workbench in comparison to 60 min when located on a wooden workbench (linac couch insert). It is found that for larger solid water stack phantoms, a transient (within 1°C) thermal equilibrium exists at the center for up to 2 h, before the temperature begins to change. This is assumed to be due to the insulating properties of multiple slices within the stack, whereby very small air spaces are introduced inhibiting the heat conduction through the phantom material. It is therefore recommended that the solid water/phantom material is kept within the treatment room for closest thermal accuracy conditions or at least placed within the room approximately 10 h before dosimetry measurements. If these options are not available, a standard linear interpolation method for calculation of temperature should be used to minimize uncertainty of temperature measurements. Medknow Publications 2008 /pmc/articles/PMC2786094/ /pubmed/20041049 http://dx.doi.org/10.4103/0971-6203.39421 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Note
Butson, Martin J.
Cheung, Tsang
Yu, Peter K. N.
Solid water phantom heat conduction: Heating and cooling rates
title Solid water phantom heat conduction: Heating and cooling rates
title_full Solid water phantom heat conduction: Heating and cooling rates
title_fullStr Solid water phantom heat conduction: Heating and cooling rates
title_full_unstemmed Solid water phantom heat conduction: Heating and cooling rates
title_short Solid water phantom heat conduction: Heating and cooling rates
title_sort solid water phantom heat conduction: heating and cooling rates
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2786094/
https://www.ncbi.nlm.nih.gov/pubmed/20041049
http://dx.doi.org/10.4103/0971-6203.39421
work_keys_str_mv AT butsonmartinj solidwaterphantomheatconductionheatingandcoolingrates
AT cheungtsang solidwaterphantomheatconductionheatingandcoolingrates
AT yupeterkn solidwaterphantomheatconductionheatingandcoolingrates