Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention

BACKGROUND: In 2005, Orange County California Emergency Medical Services (EMS) initiated a field 12-lead program to minimize time to emergency percutaneous coronary intervention (PCI) for field-identified acute myocardial infarction (MI). As the program matured, “false-positive” (defined as no PCI o...

Descripción completa

Detalles Bibliográficos
Autores principales: Swan, Pamela Yamamoto, Nighswonger, Beverly, Boswell, Gregory L., Stratton, Samuel J.
Formato: Texto
Lenguaje:English
Publicado: Department of Emergency Medicine, University of California, Irvine School of Medicine 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2791717/
https://www.ncbi.nlm.nih.gov/pubmed/20046233
_version_ 1782175188944683008
author Swan, Pamela Yamamoto
Nighswonger, Beverly
Boswell, Gregory L.
Stratton, Samuel J.
author_facet Swan, Pamela Yamamoto
Nighswonger, Beverly
Boswell, Gregory L.
Stratton, Samuel J.
author_sort Swan, Pamela Yamamoto
collection PubMed
description BACKGROUND: In 2005, Orange County California Emergency Medical Services (EMS) initiated a field 12-lead program to minimize time to emergency percutaneous coronary intervention (PCI) for field-identified acute myocardial infarction (MI). As the program matured, “false-positive” (defined as no PCI or coronary artery occlusion upon PCI) field MI activations have been identified as a problem for the program. OBJECTIVES: To identify potentially correctable factors associated with false-positive EMS triage to PCI centers. METHODS: This was a retrospective, outcome study of EMS 12-lead cases from February 2006 to June 2007. The study system exclusively used cardiac monitor internal interpretation algorithms indicating an acute myocardial infarction as the basis for triage. Indicators and variables were defined prior to the study. Data, including outcome, was from the Orange County EMS database, which included copies of 12-lead ECGs used for field triage. Negative odds ratios (OR) of less than 1.0 for positive PCI were the statistical measure of interest. RESULTS: Five hundred forty-eight patients were triaged from the field for PCI. We excluded 19 cases from the study because of death prior to PCI, refusal of PCI, and co-morbid illness (sepsis, altered consciousness) that precluded PCI. Three hundred ninety-three (74.3%) patients had PCI with significant coronary lesions found. False-positive field triages were associated with underlying cardiac rhythm of sinus tachycardia [OR = 0.38 (95% CI 0.23, 0.62)]; atrial fibrillation [OR = 0.43 (95% CI = 0.20, 0.94)]; an ECG lead not recorded [OR = 0.39 (95% CI = 0.20, 0.76)]; poor ECG baseline [OR = 0.59 (95% CI = 0.25, 1.37)]; One of three brands of monitors used in the field [OR = 0.35 (95% CI = 0.21, 0.59)]; and female gender [OR = 0.50 (95% CI = 0.34, 0.75)]. Age was not associated with false-positive triage as determined by ordinal regression (p=1.00). CONCLUSION: For the urban-suburban EMS field 12-lead program studied, age was not associated with false-positive triage. It was unexpected that female gender was associated with false-positive triage. False-positive triage from the field was associated with poor ECG acquisition, underlying rhythms of atrial fibrillation and sinus tachycardia, and one brand of 12-lead monitor.
format Text
id pubmed-2791717
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Department of Emergency Medicine, University of California, Irvine School of Medicine
record_format MEDLINE/PubMed
spelling pubmed-27917172009-12-31 Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention Swan, Pamela Yamamoto Nighswonger, Beverly Boswell, Gregory L. Stratton, Samuel J. West J Emerg Med Emergency Medical Services BACKGROUND: In 2005, Orange County California Emergency Medical Services (EMS) initiated a field 12-lead program to minimize time to emergency percutaneous coronary intervention (PCI) for field-identified acute myocardial infarction (MI). As the program matured, “false-positive” (defined as no PCI or coronary artery occlusion upon PCI) field MI activations have been identified as a problem for the program. OBJECTIVES: To identify potentially correctable factors associated with false-positive EMS triage to PCI centers. METHODS: This was a retrospective, outcome study of EMS 12-lead cases from February 2006 to June 2007. The study system exclusively used cardiac monitor internal interpretation algorithms indicating an acute myocardial infarction as the basis for triage. Indicators and variables were defined prior to the study. Data, including outcome, was from the Orange County EMS database, which included copies of 12-lead ECGs used for field triage. Negative odds ratios (OR) of less than 1.0 for positive PCI were the statistical measure of interest. RESULTS: Five hundred forty-eight patients were triaged from the field for PCI. We excluded 19 cases from the study because of death prior to PCI, refusal of PCI, and co-morbid illness (sepsis, altered consciousness) that precluded PCI. Three hundred ninety-three (74.3%) patients had PCI with significant coronary lesions found. False-positive field triages were associated with underlying cardiac rhythm of sinus tachycardia [OR = 0.38 (95% CI 0.23, 0.62)]; atrial fibrillation [OR = 0.43 (95% CI = 0.20, 0.94)]; an ECG lead not recorded [OR = 0.39 (95% CI = 0.20, 0.76)]; poor ECG baseline [OR = 0.59 (95% CI = 0.25, 1.37)]; One of three brands of monitors used in the field [OR = 0.35 (95% CI = 0.21, 0.59)]; and female gender [OR = 0.50 (95% CI = 0.34, 0.75)]. Age was not associated with false-positive triage as determined by ordinal regression (p=1.00). CONCLUSION: For the urban-suburban EMS field 12-lead program studied, age was not associated with false-positive triage. It was unexpected that female gender was associated with false-positive triage. False-positive triage from the field was associated with poor ECG acquisition, underlying rhythms of atrial fibrillation and sinus tachycardia, and one brand of 12-lead monitor. Department of Emergency Medicine, University of California, Irvine School of Medicine 2009-11 /pmc/articles/PMC2791717/ /pubmed/20046233 Text en Copyright © 2009 the authors. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by-nc/4.0/.
spellingShingle Emergency Medical Services
Swan, Pamela Yamamoto
Nighswonger, Beverly
Boswell, Gregory L.
Stratton, Samuel J.
Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title_full Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title_fullStr Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title_full_unstemmed Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title_short Factors Associated With False-Positive Emergency Medical Services Triage for Percutaneous Coronary Intervention
title_sort factors associated with false-positive emergency medical services triage for percutaneous coronary intervention
topic Emergency Medical Services
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2791717/
https://www.ncbi.nlm.nih.gov/pubmed/20046233
work_keys_str_mv AT swanpamelayamamoto factorsassociatedwithfalsepositiveemergencymedicalservicestriageforpercutaneouscoronaryintervention
AT nighswongerbeverly factorsassociatedwithfalsepositiveemergencymedicalservicestriageforpercutaneouscoronaryintervention
AT boswellgregoryl factorsassociatedwithfalsepositiveemergencymedicalservicestriageforpercutaneouscoronaryintervention
AT strattonsamuelj factorsassociatedwithfalsepositiveemergencymedicalservicestriageforpercutaneouscoronaryintervention