A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form

A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed for the simultaneous estimation of ondansetron combinations in solid dosage form with omeprazole and rabeprazole, respectively. The method involved separation of components by TLC on a precoat...

Descripción completa

Detalles Bibliográficos
Autores principales: Raval, P. B., Puranik, Manisha, Wadher, S. J., Yeole, P. G.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792513/
https://www.ncbi.nlm.nih.gov/pubmed/20046755
http://dx.doi.org/10.4103/0250-474X.43011
_version_ 1782175246795669504
author Raval, P. B.
Puranik, Manisha
Wadher, S. J.
Yeole, P. G.
author_facet Raval, P. B.
Puranik, Manisha
Wadher, S. J.
Yeole, P. G.
author_sort Raval, P. B.
collection PubMed
description A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed for the simultaneous estimation of ondansetron combinations in solid dosage form with omeprazole and rabeprazole, respectively. The method involved separation of components by TLC on a precoated silica gel 60 F(254) using a mixture of dichloromethane:methanol (9:1) as a mobile phase. Detection of spots was carried out at 309 nm and 294 nm for ondansetron with omeprazole and ondansetron with rabeprazole combinations, respectively. The mean retardation factor for ondansetron and omeprazole were found to be 0.42±0.02, 0.54±0.03, respectively while for ondansetron and rabeprazole, 0.41± 0.02 and 0.51±0.02, respectively. The linearity and range was 0.1 to 0.5 μg/spot for three drugs. The method was validated for precision, accuracy and reproducibility.
format Text
id pubmed-2792513
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27925132009-12-14 A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form Raval, P. B. Puranik, Manisha Wadher, S. J. Yeole, P. G. Indian J Pharm Sci Short Communications A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed for the simultaneous estimation of ondansetron combinations in solid dosage form with omeprazole and rabeprazole, respectively. The method involved separation of components by TLC on a precoated silica gel 60 F(254) using a mixture of dichloromethane:methanol (9:1) as a mobile phase. Detection of spots was carried out at 309 nm and 294 nm for ondansetron with omeprazole and ondansetron with rabeprazole combinations, respectively. The mean retardation factor for ondansetron and omeprazole were found to be 0.42±0.02, 0.54±0.03, respectively while for ondansetron and rabeprazole, 0.41± 0.02 and 0.51±0.02, respectively. The linearity and range was 0.1 to 0.5 μg/spot for three drugs. The method was validated for precision, accuracy and reproducibility. Medknow Publications 2008 /pmc/articles/PMC2792513/ /pubmed/20046755 http://dx.doi.org/10.4103/0250-474X.43011 Text en © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communications
Raval, P. B.
Puranik, Manisha
Wadher, S. J.
Yeole, P. G.
A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title_full A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title_fullStr A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title_full_unstemmed A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title_short A Validated HPTLC Method for Determination of Ondansetron in Combination with Omeprazole or Rabeprazole in Solid Dosage Form
title_sort validated hptlc method for determination of ondansetron in combination with omeprazole or rabeprazole in solid dosage form
topic Short Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792513/
https://www.ncbi.nlm.nih.gov/pubmed/20046755
http://dx.doi.org/10.4103/0250-474X.43011
work_keys_str_mv AT ravalpb avalidatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT puranikmanisha avalidatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT wadhersj avalidatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT yeolepg avalidatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT ravalpb validatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT puranikmanisha validatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT wadhersj validatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform
AT yeolepg validatedhptlcmethodfordeterminationofondansetronincombinationwithomeprazoleorrabeprazoleinsoliddosageform