Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system o...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792527/ https://www.ncbi.nlm.nih.gov/pubmed/20046748 http://dx.doi.org/10.4103/0250-474X.43004 |
_version_ | 1782175250214027264 |
---|---|
author | Suganthi, A. John, Sofiya Ravi, T. K. |
author_facet | Suganthi, A. John, Sofiya Ravi, T. K. |
author_sort | Suganthi, A. |
collection | PubMed |
description | A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75±0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form. |
format | Text |
id | pubmed-2792527 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-27925272009-12-14 Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form Suganthi, A. John, Sofiya Ravi, T. K. Indian J Pharm Sci Short Communications A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75±0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form. Medknow Publications 2008 /pmc/articles/PMC2792527/ /pubmed/20046748 http://dx.doi.org/10.4103/0250-474X.43004 Text en © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communications Suganthi, A. John, Sofiya Ravi, T. K. Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title | Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title_full | Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title_fullStr | Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title_full_unstemmed | Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title_short | Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form |
title_sort | simultaneous hptlc determination of rabeprazole and itopride hydrochloride from their combined dosage form |
topic | Short Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792527/ https://www.ncbi.nlm.nih.gov/pubmed/20046748 http://dx.doi.org/10.4103/0250-474X.43004 |
work_keys_str_mv | AT suganthia simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform AT johnsofiya simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform AT ravitk simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform |