Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form

A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system o...

Descripción completa

Detalles Bibliográficos
Autores principales: Suganthi, A., John, Sofiya, Ravi, T. K.
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2008
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792527/
https://www.ncbi.nlm.nih.gov/pubmed/20046748
http://dx.doi.org/10.4103/0250-474X.43004
_version_ 1782175250214027264
author Suganthi, A.
John, Sofiya
Ravi, T. K.
author_facet Suganthi, A.
John, Sofiya
Ravi, T. K.
author_sort Suganthi, A.
collection PubMed
description A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75±0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form.
format Text
id pubmed-2792527
institution National Center for Biotechnology Information
language English
publishDate 2008
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-27925272009-12-14 Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form Suganthi, A. John, Sofiya Ravi, T. K. Indian J Pharm Sci Short Communications A simple, precise, sensitive, rapid and reproducible HPTLC method for the simultaneous estimation of the rabeprazole and itopride hydrochloride in tablets was developed and validated. This method involves separation of the components by TLC on precoated silica gel G60F254 plate with solvent system of n-butanol, toluene and ammonia (8.5:0.5:1 v/v/v) and detection was carried out densitometrically using a UV detector at 288 nm in absorbance mode. This system was found to give compact spots for rabeprazole (Rf value of 0.23 0.02) and for itopride hydrochloride (Rf value of 0.75±0.02). Linearity was found to be in the range of 40-200 ng/spot and 300-1500 ng/spot for rabeprazole and itopride hydrochloride. The limit of detection and limit of quantification for rabeprazole were 10 and 20 ng/spot and for itopride hydrochloride were 50 and 100 ng/spot, respectively. The method was found to be beneficial for the routine analysis of combined dosage form. Medknow Publications 2008 /pmc/articles/PMC2792527/ /pubmed/20046748 http://dx.doi.org/10.4103/0250-474X.43004 Text en © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Communications
Suganthi, A.
John, Sofiya
Ravi, T. K.
Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title_full Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title_fullStr Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title_full_unstemmed Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title_short Simultaneous HPTLC Determination of Rabeprazole and Itopride Hydrochloride From Their Combined Dosage Form
title_sort simultaneous hptlc determination of rabeprazole and itopride hydrochloride from their combined dosage form
topic Short Communications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2792527/
https://www.ncbi.nlm.nih.gov/pubmed/20046748
http://dx.doi.org/10.4103/0250-474X.43004
work_keys_str_mv AT suganthia simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform
AT johnsofiya simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform
AT ravitk simultaneoushptlcdeterminationofrabeprazoleanditopridehydrochloridefromtheircombineddosageform