Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance

BACKGROUND: Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. MATERIALS AND METHODS: A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected mal...

Descripción completa

Detalles Bibliográficos
Autores principales: Khairnar, Krishna, Martin, Donald, Lau, Rachel, Ralevski, Filip, Pillai, Dylan R
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2796674/
https://www.ncbi.nlm.nih.gov/pubmed/20003199
http://dx.doi.org/10.1186/1475-2875-8-284
_version_ 1782175549958914048
author Khairnar, Krishna
Martin, Donald
Lau, Rachel
Ralevski, Filip
Pillai, Dylan R
author_facet Khairnar, Krishna
Martin, Donald
Lau, Rachel
Ralevski, Filip
Pillai, Dylan R
author_sort Khairnar, Krishna
collection PubMed
description BACKGROUND: Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. MATERIALS AND METHODS: A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. RESULTS: QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2 )= 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/μl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. DISCUSSION: These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. CONCLUSION: Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting.
format Text
id pubmed-2796674
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-27966742009-12-22 Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance Khairnar, Krishna Martin, Donald Lau, Rachel Ralevski, Filip Pillai, Dylan R Malar J Research BACKGROUND: Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. MATERIALS AND METHODS: A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. RESULTS: QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2 )= 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/μl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. DISCUSSION: These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. CONCLUSION: Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting. BioMed Central 2009-12-09 /pmc/articles/PMC2796674/ /pubmed/20003199 http://dx.doi.org/10.1186/1475-2875-8-284 Text en Copyright ©2009 Khairnar et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Khairnar, Krishna
Martin, Donald
Lau, Rachel
Ralevski, Filip
Pillai, Dylan R
Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title_full Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title_fullStr Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title_full_unstemmed Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title_short Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance
title_sort multiplex real-time quantitative pcr, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of plasmodium spp: performance, limit of detection analysis and quality assurance
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2796674/
https://www.ncbi.nlm.nih.gov/pubmed/20003199
http://dx.doi.org/10.1186/1475-2875-8-284
work_keys_str_mv AT khairnarkrishna multiplexrealtimequantitativepcrmicroscopyandrapiddiagnosticimmunochromatographictestsforthedetectionofplasmodiumsppperformancelimitofdetectionanalysisandqualityassurance
AT martindonald multiplexrealtimequantitativepcrmicroscopyandrapiddiagnosticimmunochromatographictestsforthedetectionofplasmodiumsppperformancelimitofdetectionanalysisandqualityassurance
AT laurachel multiplexrealtimequantitativepcrmicroscopyandrapiddiagnosticimmunochromatographictestsforthedetectionofplasmodiumsppperformancelimitofdetectionanalysisandqualityassurance
AT ralevskifilip multiplexrealtimequantitativepcrmicroscopyandrapiddiagnosticimmunochromatographictestsforthedetectionofplasmodiumsppperformancelimitofdetectionanalysisandqualityassurance
AT pillaidylanr multiplexrealtimequantitativepcrmicroscopyandrapiddiagnosticimmunochromatographictestsforthedetectionofplasmodiumsppperformancelimitofdetectionanalysisandqualityassurance