Cargando…
The pitfalls of platform comparison: DNA copy number array technologies assessed
BACKGROUND: The accurate and high resolution mapping of DNA copy number aberrations has become an important tool by which to gain insight into the mechanisms of tumourigenesis. There are various commercially available platforms for such studies, but there remains no general consensus as to the optim...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2797821/ https://www.ncbi.nlm.nih.gov/pubmed/19995423 http://dx.doi.org/10.1186/1471-2164-10-588 |
_version_ | 1782175678286790656 |
---|---|
author | Curtis, Christina Lynch, Andy G Dunning, Mark J Spiteri, Inmaculada Marioni, John C Hadfield, James Chin, Suet-Feung Brenton, James D Tavaré, Simon Caldas, Carlos |
author_facet | Curtis, Christina Lynch, Andy G Dunning, Mark J Spiteri, Inmaculada Marioni, John C Hadfield, James Chin, Suet-Feung Brenton, James D Tavaré, Simon Caldas, Carlos |
author_sort | Curtis, Christina |
collection | PubMed |
description | BACKGROUND: The accurate and high resolution mapping of DNA copy number aberrations has become an important tool by which to gain insight into the mechanisms of tumourigenesis. There are various commercially available platforms for such studies, but there remains no general consensus as to the optimal platform. There have been several previous platform comparison studies, but they have either described older technologies, used less-complex samples, or have not addressed the issue of the inherent biases in such comparisons. Here we describe a systematic comparison of data from four leading microarray technologies (the Affymetrix Genome-wide SNP 5.0 array, Agilent High-Density CGH Human 244A array, Illumina HumanCNV370-Duo DNA Analysis BeadChip, and the Nimblegen 385 K oligonucleotide array). We compare samples derived from primary breast tumours and their corresponding matched normals, well-established cancer cell lines, and HapMap individuals. By careful consideration and avoidance of potential sources of bias, we aim to provide a fair assessment of platform performance. RESULTS: By performing a theoretical assessment of the reproducibility, noise, and sensitivity of each platform, notable differences were revealed. Nimblegen exhibited between-replicate array variances an order of magnitude greater than the other three platforms, with Agilent slightly outperforming the others, and a comparison of self-self hybridizations revealed similar patterns. An assessment of the single probe power revealed that Agilent exhibits the highest sensitivity. Additionally, we performed an in-depth visual assessment of the ability of each platform to detect aberrations of varying sizes. As expected, all platforms were able to identify large aberrations in a robust manner. However, some focal amplifications and deletions were only detected in a subset of the platforms. CONCLUSION: Although there are substantial differences in the design, density, and number of replicate probes, the comparison indicates a generally high level of concordance between platforms, despite differences in the reproducibility, noise, and sensitivity. In general, Agilent tended to be the best aCGH platform and Affymetrix, the superior SNP-CGH platform, but for specific decisions the results described herein provide a guide for platform selection and study design, and the dataset a resource for more tailored comparisons. |
format | Text |
id | pubmed-2797821 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-27978212009-12-25 The pitfalls of platform comparison: DNA copy number array technologies assessed Curtis, Christina Lynch, Andy G Dunning, Mark J Spiteri, Inmaculada Marioni, John C Hadfield, James Chin, Suet-Feung Brenton, James D Tavaré, Simon Caldas, Carlos BMC Genomics Research article BACKGROUND: The accurate and high resolution mapping of DNA copy number aberrations has become an important tool by which to gain insight into the mechanisms of tumourigenesis. There are various commercially available platforms for such studies, but there remains no general consensus as to the optimal platform. There have been several previous platform comparison studies, but they have either described older technologies, used less-complex samples, or have not addressed the issue of the inherent biases in such comparisons. Here we describe a systematic comparison of data from four leading microarray technologies (the Affymetrix Genome-wide SNP 5.0 array, Agilent High-Density CGH Human 244A array, Illumina HumanCNV370-Duo DNA Analysis BeadChip, and the Nimblegen 385 K oligonucleotide array). We compare samples derived from primary breast tumours and their corresponding matched normals, well-established cancer cell lines, and HapMap individuals. By careful consideration and avoidance of potential sources of bias, we aim to provide a fair assessment of platform performance. RESULTS: By performing a theoretical assessment of the reproducibility, noise, and sensitivity of each platform, notable differences were revealed. Nimblegen exhibited between-replicate array variances an order of magnitude greater than the other three platforms, with Agilent slightly outperforming the others, and a comparison of self-self hybridizations revealed similar patterns. An assessment of the single probe power revealed that Agilent exhibits the highest sensitivity. Additionally, we performed an in-depth visual assessment of the ability of each platform to detect aberrations of varying sizes. As expected, all platforms were able to identify large aberrations in a robust manner. However, some focal amplifications and deletions were only detected in a subset of the platforms. CONCLUSION: Although there are substantial differences in the design, density, and number of replicate probes, the comparison indicates a generally high level of concordance between platforms, despite differences in the reproducibility, noise, and sensitivity. In general, Agilent tended to be the best aCGH platform and Affymetrix, the superior SNP-CGH platform, but for specific decisions the results described herein provide a guide for platform selection and study design, and the dataset a resource for more tailored comparisons. BioMed Central 2009-12-08 /pmc/articles/PMC2797821/ /pubmed/19995423 http://dx.doi.org/10.1186/1471-2164-10-588 Text en Copyright ©2009 Curtis et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research article Curtis, Christina Lynch, Andy G Dunning, Mark J Spiteri, Inmaculada Marioni, John C Hadfield, James Chin, Suet-Feung Brenton, James D Tavaré, Simon Caldas, Carlos The pitfalls of platform comparison: DNA copy number array technologies assessed |
title | The pitfalls of platform comparison: DNA copy number array technologies assessed |
title_full | The pitfalls of platform comparison: DNA copy number array technologies assessed |
title_fullStr | The pitfalls of platform comparison: DNA copy number array technologies assessed |
title_full_unstemmed | The pitfalls of platform comparison: DNA copy number array technologies assessed |
title_short | The pitfalls of platform comparison: DNA copy number array technologies assessed |
title_sort | pitfalls of platform comparison: dna copy number array technologies assessed |
topic | Research article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2797821/ https://www.ncbi.nlm.nih.gov/pubmed/19995423 http://dx.doi.org/10.1186/1471-2164-10-588 |
work_keys_str_mv | AT curtischristina thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT lynchandyg thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT dunningmarkj thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT spiteriinmaculada thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT marionijohnc thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT hadfieldjames thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT chinsuetfeung thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT brentonjamesd thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT tavaresimon thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT caldascarlos thepitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT curtischristina pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT lynchandyg pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT dunningmarkj pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT spiteriinmaculada pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT marionijohnc pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT hadfieldjames pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT chinsuetfeung pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT brentonjamesd pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT tavaresimon pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed AT caldascarlos pitfallsofplatformcomparisondnacopynumberarraytechnologiesassessed |