Cargando…
Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose?
OBJECTIVE: To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. MATERIALS AND METHODS: With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patie...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2799650/ https://www.ncbi.nlm.nih.gov/pubmed/20046494 http://dx.doi.org/10.3348/kjr.2010.11.1.46 |
_version_ | 1782175810057142272 |
---|---|
author | Prakash, Priyanka Kalra, Mannudeep K. Gilman, Matthew D. Shepard, Jo-Anne O. Digumarthy, Subba R. |
author_facet | Prakash, Priyanka Kalra, Mannudeep K. Gilman, Matthew D. Shepard, Jo-Anne O. Digumarthy, Subba R. |
author_sort | Prakash, Priyanka |
collection | PubMed |
description | OBJECTIVE: To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. MATERIALS AND METHODS: With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). RESULTS: Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). CONCLUSION: The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. |
format | Text |
id | pubmed-2799650 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-27996502010-01-01 Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? Prakash, Priyanka Kalra, Mannudeep K. Gilman, Matthew D. Shepard, Jo-Anne O. Digumarthy, Subba R. Korean J Radiol Original Article OBJECTIVE: To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. MATERIALS AND METHODS: With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). RESULTS: Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). CONCLUSION: The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. The Korean Society of Radiology 2010 2009-12-28 /pmc/articles/PMC2799650/ /pubmed/20046494 http://dx.doi.org/10.3348/kjr.2010.11.1.46 Text en Copyright © 2010 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Prakash, Priyanka Kalra, Mannudeep K. Gilman, Matthew D. Shepard, Jo-Anne O. Digumarthy, Subba R. Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title | Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title_full | Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title_fullStr | Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title_full_unstemmed | Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title_short | Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose? |
title_sort | is weight-based adjustment of automatic exposure control necessary for the reduction of chest ct radiation dose? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2799650/ https://www.ncbi.nlm.nih.gov/pubmed/20046494 http://dx.doi.org/10.3348/kjr.2010.11.1.46 |
work_keys_str_mv | AT prakashpriyanka isweightbasedadjustmentofautomaticexposurecontrolnecessaryforthereductionofchestctradiationdose AT kalramannudeepk isweightbasedadjustmentofautomaticexposurecontrolnecessaryforthereductionofchestctradiationdose AT gilmanmatthewd isweightbasedadjustmentofautomaticexposurecontrolnecessaryforthereductionofchestctradiationdose AT shepardjoanneo isweightbasedadjustmentofautomaticexposurecontrolnecessaryforthereductionofchestctradiationdose AT digumarthysubbar isweightbasedadjustmentofautomaticexposurecontrolnecessaryforthereductionofchestctradiationdose |