Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

OBJECTIVE: We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. MATERIALS AND METHODS: Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were select...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Zhonghua, Chaichana, Thanapong
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2799656/
https://www.ncbi.nlm.nih.gov/pubmed/20046500
http://dx.doi.org/10.3348/kjr.2010.11.1.95
_version_ 1782175811453845504
author Sun, Zhonghua
Chaichana, Thanapong
author_facet Sun, Zhonghua
Chaichana, Thanapong
author_sort Sun, Zhonghua
collection PubMed
description OBJECTIVE: We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. MATERIALS AND METHODS: Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. RESULTS: Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. CONCLUSION: Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.
format Text
id pubmed-2799656
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-27996562010-01-01 Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries Sun, Zhonghua Chaichana, Thanapong Korean J Radiol Original Article OBJECTIVE: We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. MATERIALS AND METHODS: Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. RESULTS: Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. CONCLUSION: Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair. The Korean Society of Radiology 2010 2009-12-28 /pmc/articles/PMC2799656/ /pubmed/20046500 http://dx.doi.org/10.3348/kjr.2010.11.1.95 Text en Copyright © 2010 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Sun, Zhonghua
Chaichana, Thanapong
Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title_full Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title_fullStr Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title_full_unstemmed Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title_short Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries
title_sort fenestrated stent graft repair of abdominal aortic aneurysm: hemodynamic analysis of the effect of fenestrated stents on the renal arteries
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2799656/
https://www.ncbi.nlm.nih.gov/pubmed/20046500
http://dx.doi.org/10.3348/kjr.2010.11.1.95
work_keys_str_mv AT sunzhonghua fenestratedstentgraftrepairofabdominalaorticaneurysmhemodynamicanalysisoftheeffectoffenestratedstentsontherenalarteries
AT chaichanathanapong fenestratedstentgraftrepairofabdominalaorticaneurysmhemodynamicanalysisoftheeffectoffenestratedstentsontherenalarteries