Cargando…
Ultrasonographic examination of the carpal canal in dogs
The aim of this study was to determine the course of the median nerve and its adjacent structures in the carpal canals of 8 healthy dogs by using high-frequency transducers. Before performing ultrasonography, the transverse and posteroanterior diameters as well as the perimeter of the carpus were me...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Veterinary Science
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801093/ https://www.ncbi.nlm.nih.gov/pubmed/19255528 http://dx.doi.org/10.4142/jvs.2009.10.1.77 |
_version_ | 1782175897365774336 |
---|---|
author | Turan, Erkut Ozsunar, Yelda Yildirim, Ismail Gokce |
author_facet | Turan, Erkut Ozsunar, Yelda Yildirim, Ismail Gokce |
author_sort | Turan, Erkut |
collection | PubMed |
description | The aim of this study was to determine the course of the median nerve and its adjacent structures in the carpal canals of 8 healthy dogs by using high-frequency transducers. Before performing ultrasonography, the transverse and posteroanterior diameters as well as the perimeter of the carpus were measured at just proximal to the side of the carpal pad. The anatomical structures were then determined at two levels of the carpal canal, which were named the proximal and distal levels, on the transverse sonograms. The cross-sectional areas, perimeters and the transverse and posteroanterior diameters of the median nerve were measured at these levels. Although all the measurements were larger at the proximal level, significant differences between the proximal and distal levels were determined for the cross-sectional area, the perimeter and the transverse diameter of the median nerve. On the transverse sonogram, the deep digital flexor tendon was seen in almost the center of the carpal canal like a comma shape and also it had a small concavity on the caudal side. The superficial digital flexor tendon was seen as an ovoid shape on the transverse sonograms and it was located nearly at the posterior side of the carpal canal. Both tendons were seen as intermediate-grade echogenic structures. The median artery was located inside of the concavity of the deep digital flexor tendon. Also, the median nerve was seen at the posteromedial side of the median artery. As a result of this study, the cross-sectional areas of the median nerve ranged between 1.01-2.68 mm(2) at the proximal level and between 0.93-1.91 mm(2) at the distal level. |
format | Text |
id | pubmed-2801093 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | The Korean Society of Veterinary Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-28010932010-01-11 Ultrasonographic examination of the carpal canal in dogs Turan, Erkut Ozsunar, Yelda Yildirim, Ismail Gokce J Vet Sci Original Article The aim of this study was to determine the course of the median nerve and its adjacent structures in the carpal canals of 8 healthy dogs by using high-frequency transducers. Before performing ultrasonography, the transverse and posteroanterior diameters as well as the perimeter of the carpus were measured at just proximal to the side of the carpal pad. The anatomical structures were then determined at two levels of the carpal canal, which were named the proximal and distal levels, on the transverse sonograms. The cross-sectional areas, perimeters and the transverse and posteroanterior diameters of the median nerve were measured at these levels. Although all the measurements were larger at the proximal level, significant differences between the proximal and distal levels were determined for the cross-sectional area, the perimeter and the transverse diameter of the median nerve. On the transverse sonogram, the deep digital flexor tendon was seen in almost the center of the carpal canal like a comma shape and also it had a small concavity on the caudal side. The superficial digital flexor tendon was seen as an ovoid shape on the transverse sonograms and it was located nearly at the posterior side of the carpal canal. Both tendons were seen as intermediate-grade echogenic structures. The median artery was located inside of the concavity of the deep digital flexor tendon. Also, the median nerve was seen at the posteromedial side of the median artery. As a result of this study, the cross-sectional areas of the median nerve ranged between 1.01-2.68 mm(2) at the proximal level and between 0.93-1.91 mm(2) at the distal level. The Korean Society of Veterinary Science 2009-03 2009-03-31 /pmc/articles/PMC2801093/ /pubmed/19255528 http://dx.doi.org/10.4142/jvs.2009.10.1.77 Text en Copyright © 2009 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Turan, Erkut Ozsunar, Yelda Yildirim, Ismail Gokce Ultrasonographic examination of the carpal canal in dogs |
title | Ultrasonographic examination of the carpal canal in dogs |
title_full | Ultrasonographic examination of the carpal canal in dogs |
title_fullStr | Ultrasonographic examination of the carpal canal in dogs |
title_full_unstemmed | Ultrasonographic examination of the carpal canal in dogs |
title_short | Ultrasonographic examination of the carpal canal in dogs |
title_sort | ultrasonographic examination of the carpal canal in dogs |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801093/ https://www.ncbi.nlm.nih.gov/pubmed/19255528 http://dx.doi.org/10.4142/jvs.2009.10.1.77 |
work_keys_str_mv | AT turanerkut ultrasonographicexaminationofthecarpalcanalindogs AT ozsunaryelda ultrasonographicexaminationofthecarpalcanalindogs AT yildirimismailgokce ultrasonographicexaminationofthecarpalcanalindogs |