Cargando…

The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG

Electroretinography (ERG) is a reliable diagnostic tool for the diagnosis of retinal disease. It measures electric potentials occurring in the retina in response to light stimulation. In this study, we examined the normal electroretinogram using the Handheld Multispecies ERG (HMsERG) in Shih Tzu dog...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, June-sub, Kim, Kyung-hee, Jang, Ha-young, Lee, Bora, Kim, Joon Young, Jeong, Soon-wuk
Formato: Texto
Lenguaje:English
Publicado: The Korean Society of Veterinary Science 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801126/
https://www.ncbi.nlm.nih.gov/pubmed/19687624
http://dx.doi.org/10.4142/jvs.2009.10.3.233
_version_ 1782175906082586624
author Lee, June-sub
Kim, Kyung-hee
Jang, Ha-young
Lee, Bora
Kim, Joon Young
Jeong, Soon-wuk
author_facet Lee, June-sub
Kim, Kyung-hee
Jang, Ha-young
Lee, Bora
Kim, Joon Young
Jeong, Soon-wuk
author_sort Lee, June-sub
collection PubMed
description Electroretinography (ERG) is a reliable diagnostic tool for the diagnosis of retinal disease. It measures electric potentials occurring in the retina in response to light stimulation. In this study, we examined the normal electroretinogram using the Handheld Multispecies ERG (HMsERG) in Shih Tzu dogs. ERG recordings were performed in twelve eyes of six healthy Shih Tzu dogs. Dogs were anesthetized with a combination of medetomidine and ketamine. Proparacaine eye drops were also applied as a topical anesthetic. Tropicamide eye drops were applied for mydriasis. After 20 min of dark adaptation, we recorded the amplitudes and implicit times of the b-waves of the rod, standard rod and cone (Std R&C), high-intensity rod and cone (Hi-int R&C), and cone systems, and responses of the cones and inner retina by flicker light stimulation (cone flicker). Results showed that mean the amplitudes of a-waves of Std R&C, Hi-int R&C, and the cone responses were 141.25 µV, 173.00 µV, and 12.92 µV, respectively. The b-waves of the rod responses ranged from 141.58 to 155.25 µV; the Std R&C was 314.75 µV, the Hi-int R&C was 329.42 µV, the cones were 37.75 µV, and the flicker responses were 64.08 µV. The b/a ratios for the Std R&C, Hi-int R&C, and the cone response were 2.29, 1.94, and 3.71, respectively. Mean implicit time of the a-wave of the Std R&C was 15.12 ms, of Hi-int R&C was 13.42 ms, and of the cone response was 7.22 ms. The b-wave of the rod responses ranged from 68.12 to 72.68 ms, of Std R&C were 37.28 ms, of Hi-int R&C were 41.90, of the cone responses were 38.12 ms, and of the cone flicker responses were 22.80 ms. We believe that these parameters can be used as reference "normal" ERGs ranges for Shih Tzu dogs using the HMsERG under medetomidine and ketamine anesthesia.
format Text
id pubmed-2801126
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher The Korean Society of Veterinary Science
record_format MEDLINE/PubMed
spelling pubmed-28011262010-01-11 The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG Lee, June-sub Kim, Kyung-hee Jang, Ha-young Lee, Bora Kim, Joon Young Jeong, Soon-wuk J Vet Sci Original Article Electroretinography (ERG) is a reliable diagnostic tool for the diagnosis of retinal disease. It measures electric potentials occurring in the retina in response to light stimulation. In this study, we examined the normal electroretinogram using the Handheld Multispecies ERG (HMsERG) in Shih Tzu dogs. ERG recordings were performed in twelve eyes of six healthy Shih Tzu dogs. Dogs were anesthetized with a combination of medetomidine and ketamine. Proparacaine eye drops were also applied as a topical anesthetic. Tropicamide eye drops were applied for mydriasis. After 20 min of dark adaptation, we recorded the amplitudes and implicit times of the b-waves of the rod, standard rod and cone (Std R&C), high-intensity rod and cone (Hi-int R&C), and cone systems, and responses of the cones and inner retina by flicker light stimulation (cone flicker). Results showed that mean the amplitudes of a-waves of Std R&C, Hi-int R&C, and the cone responses were 141.25 µV, 173.00 µV, and 12.92 µV, respectively. The b-waves of the rod responses ranged from 141.58 to 155.25 µV; the Std R&C was 314.75 µV, the Hi-int R&C was 329.42 µV, the cones were 37.75 µV, and the flicker responses were 64.08 µV. The b/a ratios for the Std R&C, Hi-int R&C, and the cone response were 2.29, 1.94, and 3.71, respectively. Mean implicit time of the a-wave of the Std R&C was 15.12 ms, of Hi-int R&C was 13.42 ms, and of the cone response was 7.22 ms. The b-wave of the rod responses ranged from 68.12 to 72.68 ms, of Std R&C were 37.28 ms, of Hi-int R&C were 41.90, of the cone responses were 38.12 ms, and of the cone flicker responses were 22.80 ms. We believe that these parameters can be used as reference "normal" ERGs ranges for Shih Tzu dogs using the HMsERG under medetomidine and ketamine anesthesia. The Korean Society of Veterinary Science 2009-09 2009-09-07 /pmc/articles/PMC2801126/ /pubmed/19687624 http://dx.doi.org/10.4142/jvs.2009.10.3.233 Text en Copyright © 2009 The Korean Society of Veterinary Science https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, June-sub
Kim, Kyung-hee
Jang, Ha-young
Lee, Bora
Kim, Joon Young
Jeong, Soon-wuk
The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title_full The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title_fullStr The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title_full_unstemmed The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title_short The normal electroretinogram in adult healthy Shih Tzu dogs using the HMsERG
title_sort normal electroretinogram in adult healthy shih tzu dogs using the hmserg
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2801126/
https://www.ncbi.nlm.nih.gov/pubmed/19687624
http://dx.doi.org/10.4142/jvs.2009.10.3.233
work_keys_str_mv AT leejunesub thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT kimkyunghee thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT janghayoung thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT leebora thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT kimjoonyoung thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT jeongsoonwuk thenormalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT leejunesub normalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT kimkyunghee normalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT janghayoung normalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT leebora normalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT kimjoonyoung normalelectroretinograminadulthealthyshihtzudogsusingthehmserg
AT jeongsoonwuk normalelectroretinograminadulthealthyshihtzudogsusingthehmserg