Cargando…
Clinical measurement and categorization of optic disc in glaucoma patients
BACKGROUND: Assessment of optic disc size is an important component of optic nerve head examination. Agreement between different methods of disc size measurements is not very good. PURPOSE: To assess the agreement between the disc size assessed by Heidelberg retina tomograph (HRT) and stereobiomicro...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2804124/ https://www.ncbi.nlm.nih.gov/pubmed/19700874 http://dx.doi.org/10.4103/0301-4738.55075 |
Sumario: | BACKGROUND: Assessment of optic disc size is an important component of optic nerve head examination. Agreement between different methods of disc size measurements is not very good. PURPOSE: To assess the agreement between the disc size assessed by Heidelberg retina tomograph (HRT) and stereobiomicroscopy with a 90 diopter (D) lens. To report the clinical (measured by biomicroscopy) disc diameters of small, average and large optic discs categorized by HRT disc areas. SETTING AND DESIGN: Observational study of subjects examined in the glaucoma clinic of a tertiary eye institute. MATERIALS AND METHODS: Seventy-five eyes of 75 glaucoma subjects were studied. Disc diameter was measured using stereobiomicroscopy and HRT. The agreement between the two sets of measurements was assessed by intraclass correlation coefficient (ICC). Discs were classified into small (<1.6 mm(2)), average (1.6-2.6 mm(2)) and large (>2.6 mm(2)) depending on cutoffs provided by the manufacturers of HRT. The means (95% CI) of the corresponding vertical disc diameter in these groups were assessed. STATISTICAL ANALYSIS: ICC, Bland and Altman plots. RESULTS: ICC for measurements of clinical and HRT horizontal disc diameter was 0.518 and for vertical disc diameter measurement was 0.487. The mean difference between the clinical and HRT measurements as analyzed by the Bland and Altman plot was 0.17 (95% CI, 0.13- 0.47) for horizontal and 0.22 (95% CI, 0.11- 0.54) for vertical disc diameter. Of the 75 eyes, 3 eyes had small discs, 54 average and 18 large discs. The mean clinical vertical disc diameter for small discs was 1.55 mm (95% CI, 1.2-1.7), for average discs was 1.91 mm (95% CI, 1.87-1.96) and for large discs was 2.15 mm (95% CI, 2.03–2.27). CONCLUSION: The agreement between clinical and HRT disc diameter measurements is moderate. Disc diameter measurement on stereobiomicroscopy can be used to categorize discs into small, average and large discs. |
---|