Cargando…
Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system
The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal Radiotherapy (3D-CRT), and Intensity Modulated Radiotherapy (IMRT) for different sites, and to s...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2804143/ https://www.ncbi.nlm.nih.gov/pubmed/20126561 http://dx.doi.org/10.4103/0971-6203.48716 |
_version_ | 1782176144273965056 |
---|---|
author | Muralidhar, K. R. Murthy, Narayana P. Raju, Alluri Krishnam Sresty, NVNM |
author_facet | Muralidhar, K. R. Murthy, Narayana P. Raju, Alluri Krishnam Sresty, NVNM |
author_sort | Muralidhar, K. R. |
collection | PubMed |
description | The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal Radiotherapy (3D-CRT), and Intensity Modulated Radiotherapy (IMRT) for different sites, and to study the suitability of algorithms with respect to site and technique. For each of the Conventional, 3D-CRT, and IMRT techniques, four different sites, namely, Lung, Esophagus, Prostate, and Hypopharynx were analyzed. Treatment plans were created using 6MV Photon beam quality using the CMS XiO (Computerized Medical System, St.Louis, MO) treatment planning system. The maximum percentage of variation recorded between algorithms was 3.7% in case of Ca.Lung, for the IMRT Technique. Statistical analysis was performed by comparing the mean relative difference, Conformity Index, and Homogeneity Index for target structures. The fast superposition algorithm showed excellent results for lung and esophagus cases for all techniques. For the prostate, the superposition algorithm showed better results in all techniques. In the conventional case of the hypopharynx, the convolution algorithm was good. In case of Ca. Lung, Ca Prostate, Ca Esophagus, and Ca Hypopharynx, OARs got more doses with the superposition algorithm; this progressively decreased for fast superposition and convolution algorithms, respectively. According to this study the dosimetric results using different algorithms led to significant variation and therefore care had to be taken while evaluating treatment plans. The choice of a dose calculation algorithm may in certain cases even influence clinical results. |
format | Text |
id | pubmed-2804143 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-28041432010-02-01 Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system Muralidhar, K. R. Murthy, Narayana P. Raju, Alluri Krishnam Sresty, NVNM J Med Phys Original Article The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal Radiotherapy (3D-CRT), and Intensity Modulated Radiotherapy (IMRT) for different sites, and to study the suitability of algorithms with respect to site and technique. For each of the Conventional, 3D-CRT, and IMRT techniques, four different sites, namely, Lung, Esophagus, Prostate, and Hypopharynx were analyzed. Treatment plans were created using 6MV Photon beam quality using the CMS XiO (Computerized Medical System, St.Louis, MO) treatment planning system. The maximum percentage of variation recorded between algorithms was 3.7% in case of Ca.Lung, for the IMRT Technique. Statistical analysis was performed by comparing the mean relative difference, Conformity Index, and Homogeneity Index for target structures. The fast superposition algorithm showed excellent results for lung and esophagus cases for all techniques. For the prostate, the superposition algorithm showed better results in all techniques. In the conventional case of the hypopharynx, the convolution algorithm was good. In case of Ca. Lung, Ca Prostate, Ca Esophagus, and Ca Hypopharynx, OARs got more doses with the superposition algorithm; this progressively decreased for fast superposition and convolution algorithms, respectively. According to this study the dosimetric results using different algorithms led to significant variation and therefore care had to be taken while evaluating treatment plans. The choice of a dose calculation algorithm may in certain cases even influence clinical results. Medknow Publications 2009 /pmc/articles/PMC2804143/ /pubmed/20126561 http://dx.doi.org/10.4103/0971-6203.48716 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Muralidhar, K. R. Murthy, Narayana P. Raju, Alluri Krishnam Sresty, NVNM Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title | Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title_full | Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title_fullStr | Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title_full_unstemmed | Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title_short | Comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on CMS XIO planning system |
title_sort | comparative study of convolution, superposition, and fast superposition algorithms in conventional radiotherapy, three-dimensional conformal radiotherapy, and intensity modulated radiotherapy techniques for various sites, done on cms xio planning system |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2804143/ https://www.ncbi.nlm.nih.gov/pubmed/20126561 http://dx.doi.org/10.4103/0971-6203.48716 |
work_keys_str_mv | AT muralidharkr comparativestudyofconvolutionsuperpositionandfastsuperpositionalgorithmsinconventionalradiotherapythreedimensionalconformalradiotherapyandintensitymodulatedradiotherapytechniquesforvarioussitesdoneoncmsxioplanningsystem AT murthynarayanap comparativestudyofconvolutionsuperpositionandfastsuperpositionalgorithmsinconventionalradiotherapythreedimensionalconformalradiotherapyandintensitymodulatedradiotherapytechniquesforvarioussitesdoneoncmsxioplanningsystem AT rajuallurikrishnam comparativestudyofconvolutionsuperpositionandfastsuperpositionalgorithmsinconventionalradiotherapythreedimensionalconformalradiotherapyandintensitymodulatedradiotherapytechniquesforvarioussitesdoneoncmsxioplanningsystem AT srestynvnm comparativestudyofconvolutionsuperpositionandfastsuperpositionalgorithmsinconventionalradiotherapythreedimensionalconformalradiotherapyandintensitymodulatedradiotherapytechniquesforvarioussitesdoneoncmsxioplanningsystem |