Cargando…

The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guided radiation therapy (IMRT and IGRT) have been limited almost exclusively to linear accelerators. Investigations of modern Cobalt-60 (Co-60) radiation delivery in the context of IMRT...

Descripción completa

Detalles Bibliográficos
Autores principales: Schreiner, L. John, Joshi, Chandra P., Darko, Johnson, Kerr, Andrew, Salomons, Greg, Dhanesar, Sandeep
Formato: Texto
Lenguaje:English
Publicado: Medknow Publications 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2807677/
https://www.ncbi.nlm.nih.gov/pubmed/20098559
http://dx.doi.org/10.4103/0971-6203.54846
_version_ 1782176419459104768
author Schreiner, L. John
Joshi, Chandra P.
Darko, Johnson
Kerr, Andrew
Salomons, Greg
Dhanesar, Sandeep
author_facet Schreiner, L. John
Joshi, Chandra P.
Darko, Johnson
Kerr, Andrew
Salomons, Greg
Dhanesar, Sandeep
author_sort Schreiner, L. John
collection PubMed
description The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guided radiation therapy (IMRT and IGRT) have been limited almost exclusively to linear accelerators. Investigations of modern Cobalt-60 (Co-60) radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.
format Text
id pubmed-2807677
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Medknow Publications
record_format MEDLINE/PubMed
spelling pubmed-28076772010-01-22 The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance Schreiner, L. John Joshi, Chandra P. Darko, Johnson Kerr, Andrew Salomons, Greg Dhanesar, Sandeep J Med Phys Invited Paper The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guided radiation therapy (IMRT and IGRT) have been limited almost exclusively to linear accelerators. Investigations of modern Cobalt-60 (Co-60) radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices. Medknow Publications 2009 /pmc/articles/PMC2807677/ /pubmed/20098559 http://dx.doi.org/10.4103/0971-6203.54846 Text en © Journal of Medical Physics http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Invited Paper
Schreiner, L. John
Joshi, Chandra P.
Darko, Johnson
Kerr, Andrew
Salomons, Greg
Dhanesar, Sandeep
The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title_full The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title_fullStr The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title_full_unstemmed The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title_short The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance
title_sort role of cobalt-60 in modern radiation therapy: dose delivery and image guidance
topic Invited Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2807677/
https://www.ncbi.nlm.nih.gov/pubmed/20098559
http://dx.doi.org/10.4103/0971-6203.54846
work_keys_str_mv AT schreinerljohn theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT joshichandrap theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT darkojohnson theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT kerrandrew theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT salomonsgreg theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT dhanesarsandeep theroleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT schreinerljohn roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT joshichandrap roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT darkojohnson roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT kerrandrew roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT salomonsgreg roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance
AT dhanesarsandeep roleofcobalt60inmodernradiationtherapydosedeliveryandimageguidance