DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity
Insulin sensitivity (SI) estimation has numerous uses in medical and clinical situations. However, highresolution tests that are useful for clinical diagnosis and monitoring are often too intensive, long and costly for regular use. Simpler tests that mitigate these issues are not accurate enough for...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2812840/ https://www.ncbi.nlm.nih.gov/pubmed/20148062 http://dx.doi.org/10.2174/1874431100903010065 |
_version_ | 1782176870569082880 |
---|---|
author | Docherty, Paul D Chase, J. Geoffrey Lotz, Thomas Hann, Christopher E Shaw, Geoffrey M Berkeley, Juliet E Mann, J.I McAuley, Kirsten |
author_facet | Docherty, Paul D Chase, J. Geoffrey Lotz, Thomas Hann, Christopher E Shaw, Geoffrey M Berkeley, Juliet E Mann, J.I McAuley, Kirsten |
author_sort | Docherty, Paul D |
collection | PubMed |
description | Insulin sensitivity (SI) estimation has numerous uses in medical and clinical situations. However, highresolution tests that are useful for clinical diagnosis and monitoring are often too intensive, long and costly for regular use. Simpler tests that mitigate these issues are not accurate enough for many clinical diagnostic or monitoring scenarios. The gap between these tests presents an opportunity for new approaches. The quick dynamic insulin sensitivity test (DISTq) utilises the model-based DIST test protocol and a series of population estimates to eliminate the need for insulin or C-peptide assays to enable a high resolution, low-intensity, real-time evaluation of SI. The method predicts patient specific insulin responses to the DIST test protocol with enough accuracy to yield a useful clinical insulin sensitivity metric for monitoring of diabetes therapy. The DISTq method replicated the findings of the fully sampled DIST test without the use of insulin or C-peptide assays. Correlations of the resulting SI values was R=0.91. The method was also compared to the euglycaemic hyperinsulinaemic clamp (EIC) in an in-silico Monte-Carlo analysis and showed a good ability to re-evaluate SI(EIC) (R=0.89), compared to the fully sampled DIST (R=0.98) Population-derived parameter estimates using a-posteriori population-based functions derived from DIST test data enables the simulation of insulin profiles that are sufficiently accurate to estimate SI to a relatively high precision. Thus, costly insulin and C-peptide assays are not necessary to obtain an accurate, but inexpensive, real-time estimate of insulin sensitivity. This estimate has enough resolution for SI prediction and monitoring of response to therapy. In borderline cases, re-evaluation of stored (frozen) blood samples for insulin and C-peptide would enable greater accuracy where necessary, enabling a hierarchy of tests in an economical fashion. |
format | Text |
id | pubmed-2812840 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Bentham Open |
record_format | MEDLINE/PubMed |
spelling | pubmed-28128402010-02-10 DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity Docherty, Paul D Chase, J. Geoffrey Lotz, Thomas Hann, Christopher E Shaw, Geoffrey M Berkeley, Juliet E Mann, J.I McAuley, Kirsten Open Med Inform J Article Insulin sensitivity (SI) estimation has numerous uses in medical and clinical situations. However, highresolution tests that are useful for clinical diagnosis and monitoring are often too intensive, long and costly for regular use. Simpler tests that mitigate these issues are not accurate enough for many clinical diagnostic or monitoring scenarios. The gap between these tests presents an opportunity for new approaches. The quick dynamic insulin sensitivity test (DISTq) utilises the model-based DIST test protocol and a series of population estimates to eliminate the need for insulin or C-peptide assays to enable a high resolution, low-intensity, real-time evaluation of SI. The method predicts patient specific insulin responses to the DIST test protocol with enough accuracy to yield a useful clinical insulin sensitivity metric for monitoring of diabetes therapy. The DISTq method replicated the findings of the fully sampled DIST test without the use of insulin or C-peptide assays. Correlations of the resulting SI values was R=0.91. The method was also compared to the euglycaemic hyperinsulinaemic clamp (EIC) in an in-silico Monte-Carlo analysis and showed a good ability to re-evaluate SI(EIC) (R=0.89), compared to the fully sampled DIST (R=0.98) Population-derived parameter estimates using a-posteriori population-based functions derived from DIST test data enables the simulation of insulin profiles that are sufficiently accurate to estimate SI to a relatively high precision. Thus, costly insulin and C-peptide assays are not necessary to obtain an accurate, but inexpensive, real-time estimate of insulin sensitivity. This estimate has enough resolution for SI prediction and monitoring of response to therapy. In borderline cases, re-evaluation of stored (frozen) blood samples for insulin and C-peptide would enable greater accuracy where necessary, enabling a hierarchy of tests in an economical fashion. Bentham Open 2009-12-02 /pmc/articles/PMC2812840/ /pubmed/20148062 http://dx.doi.org/10.2174/1874431100903010065 Text en © Docherty et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited. |
spellingShingle | Article Docherty, Paul D Chase, J. Geoffrey Lotz, Thomas Hann, Christopher E Shaw, Geoffrey M Berkeley, Juliet E Mann, J.I McAuley, Kirsten DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title | DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title_full | DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title_fullStr | DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title_full_unstemmed | DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title_short | DISTq: An Iterative Analysis of Glucose Data for Low-Cost, Real-Time and Accurate Estimation of Insulin Sensitivity |
title_sort | distq: an iterative analysis of glucose data for low-cost, real-time and accurate estimation of insulin sensitivity |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2812840/ https://www.ncbi.nlm.nih.gov/pubmed/20148062 http://dx.doi.org/10.2174/1874431100903010065 |
work_keys_str_mv | AT dochertypauld distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT chasejgeoffrey distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT lotzthomas distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT hannchristophere distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT shawgeoffreym distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT berkeleyjuliete distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT mannji distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity AT mcauleykirsten distqaniterativeanalysisofglucosedataforlowcostrealtimeandaccurateestimationofinsulinsensitivity |