Cargando…

Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise

BACKGROUND: Although non-specific pain in the upper limb muscles of workers engaged in mild repetitive tasks is a common occupational health problem, much is unknown about the associated structural and biochemical changes. In this study, we compared the muscle energy metabolism of the extrinsic fing...

Descripción completa

Detalles Bibliográficos
Autores principales: Moreno-Torres, Angel, Rosset-Llobet, Jaume, Pujol, Jesus, Fàbregas, Sílvia, Gonzalez-de-Suso, Jose-Manuel
Formato: Texto
Lenguaje:English
Publicado: Public Library of Science 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2817730/
https://www.ncbi.nlm.nih.gov/pubmed/20161738
http://dx.doi.org/10.1371/journal.pone.0009091
_version_ 1782177236389986304
author Moreno-Torres, Angel
Rosset-Llobet, Jaume
Pujol, Jesus
Fàbregas, Sílvia
Gonzalez-de-Suso, Jose-Manuel
author_facet Moreno-Torres, Angel
Rosset-Llobet, Jaume
Pujol, Jesus
Fàbregas, Sílvia
Gonzalez-de-Suso, Jose-Manuel
author_sort Moreno-Torres, Angel
collection PubMed
description BACKGROUND: Although non-specific pain in the upper limb muscles of workers engaged in mild repetitive tasks is a common occupational health problem, much is unknown about the associated structural and biochemical changes. In this study, we compared the muscle energy metabolism of the extrinsic finger extensor musculature in instrumentalists suffering from work-related pain with that of healthy control instrumentalists using non-invasive phosphorus magnetic resonance spectroscopy ((31)P-MRS). We hypothesize that the affected muscles will show alterations related with an impaired energy metabolism. METHODOLOGY/PRINCIPAL FINDINGS: We studied 19 volunteer instrumentalists (11 subjects with work-related pain affecting the extrinsic finger extensor musculature and 8 healthy controls). We used (31)P-MRS to find deviations from the expected metabolic response to exercise in phosphocreatine (PCr), inorganic phosphate (Pi), Pi/PCr ratio and intracellular pH kinetics. We observed a reduced finger extensor exercise tolerance in instrumentalists with myalgia, an intracellular pH compartmentation in the form of neutral and acid compartments, as detected by Pi peak splitting in (31)P-MRS spectra, predominantly in myalgic muscles, and a strong association of this pattern with the condition. CONCLUSIONS/SIGNIFICANCE: Work-related pain in the finger extrinsic extensor muscles is associated with intracellular pH compartmentation during exercise, non-invasively detectable by (31)P-MRS and consistent with the simultaneous energy production by oxidative metabolism and glycolysis. We speculate that a deficit in energy production by oxidative pathways may exist in the affected muscles. Two possible explanations for this would be the partial and/or local reduction of blood supply and the reduction of the muscle oxidative capacity itself.
format Text
id pubmed-2817730
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-28177302010-02-17 Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise Moreno-Torres, Angel Rosset-Llobet, Jaume Pujol, Jesus Fàbregas, Sílvia Gonzalez-de-Suso, Jose-Manuel PLoS One Research Article BACKGROUND: Although non-specific pain in the upper limb muscles of workers engaged in mild repetitive tasks is a common occupational health problem, much is unknown about the associated structural and biochemical changes. In this study, we compared the muscle energy metabolism of the extrinsic finger extensor musculature in instrumentalists suffering from work-related pain with that of healthy control instrumentalists using non-invasive phosphorus magnetic resonance spectroscopy ((31)P-MRS). We hypothesize that the affected muscles will show alterations related with an impaired energy metabolism. METHODOLOGY/PRINCIPAL FINDINGS: We studied 19 volunteer instrumentalists (11 subjects with work-related pain affecting the extrinsic finger extensor musculature and 8 healthy controls). We used (31)P-MRS to find deviations from the expected metabolic response to exercise in phosphocreatine (PCr), inorganic phosphate (Pi), Pi/PCr ratio and intracellular pH kinetics. We observed a reduced finger extensor exercise tolerance in instrumentalists with myalgia, an intracellular pH compartmentation in the form of neutral and acid compartments, as detected by Pi peak splitting in (31)P-MRS spectra, predominantly in myalgic muscles, and a strong association of this pattern with the condition. CONCLUSIONS/SIGNIFICANCE: Work-related pain in the finger extrinsic extensor muscles is associated with intracellular pH compartmentation during exercise, non-invasively detectable by (31)P-MRS and consistent with the simultaneous energy production by oxidative metabolism and glycolysis. We speculate that a deficit in energy production by oxidative pathways may exist in the affected muscles. Two possible explanations for this would be the partial and/or local reduction of blood supply and the reduction of the muscle oxidative capacity itself. Public Library of Science 2010-02-09 /pmc/articles/PMC2817730/ /pubmed/20161738 http://dx.doi.org/10.1371/journal.pone.0009091 Text en Moreno-Torres et al. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Moreno-Torres, Angel
Rosset-Llobet, Jaume
Pujol, Jesus
Fàbregas, Sílvia
Gonzalez-de-Suso, Jose-Manuel
Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title_full Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title_fullStr Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title_full_unstemmed Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title_short Work-Related Pain in Extrinsic Finger Extensor Musculature of Instrumentalists Is Associated with Intracellular pH Compartmentation during Exercise
title_sort work-related pain in extrinsic finger extensor musculature of instrumentalists is associated with intracellular ph compartmentation during exercise
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2817730/
https://www.ncbi.nlm.nih.gov/pubmed/20161738
http://dx.doi.org/10.1371/journal.pone.0009091
work_keys_str_mv AT morenotorresangel workrelatedpaininextrinsicfingerextensormusculatureofinstrumentalistsisassociatedwithintracellularphcompartmentationduringexercise
AT rossetllobetjaume workrelatedpaininextrinsicfingerextensormusculatureofinstrumentalistsisassociatedwithintracellularphcompartmentationduringexercise
AT pujoljesus workrelatedpaininextrinsicfingerextensormusculatureofinstrumentalistsisassociatedwithintracellularphcompartmentationduringexercise
AT fabregassilvia workrelatedpaininextrinsicfingerextensormusculatureofinstrumentalistsisassociatedwithintracellularphcompartmentationduringexercise
AT gonzalezdesusojosemanuel workrelatedpaininextrinsicfingerextensormusculatureofinstrumentalistsisassociatedwithintracellularphcompartmentationduringexercise