Cargando…
Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determ...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2820259/ https://www.ncbi.nlm.nih.gov/pubmed/20168976 http://dx.doi.org/10.1155/2009/148527 |
_version_ | 1782177356544212992 |
---|---|
author | Nicoara, Simona Tonidandel, Loris Traldi, Pietro Watson, Jonathan Morgan, Geraint Popa, Ovidiu |
author_facet | Nicoara, Simona Tonidandel, Loris Traldi, Pietro Watson, Jonathan Morgan, Geraint Popa, Ovidiu |
author_sort | Nicoara, Simona |
collection | PubMed |
description | The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m(3) (B), 13–90 μg/m(3) (T), 7–50 μg/m(3) (E), 10–70 μg/m(3) (X-m,p), and 20–130 μg/m(3) (X-o). The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m(3) (Xo), 5/3 μg/m(3) (B, E, X-m,p), and of 3/1 μg/m(3) (T), respectively. |
format | Text |
id | pubmed-2820259 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-28202592010-02-18 Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method Nicoara, Simona Tonidandel, Loris Traldi, Pietro Watson, Jonathan Morgan, Geraint Popa, Ovidiu J Environ Public Health Research Article The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m(3) (B), 13–90 μg/m(3) (T), 7–50 μg/m(3) (E), 10–70 μg/m(3) (X-m,p), and 20–130 μg/m(3) (X-o). The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m(3) (Xo), 5/3 μg/m(3) (B, E, X-m,p), and of 3/1 μg/m(3) (T), respectively. Hindawi Publishing Corporation 2009 2010-02-03 /pmc/articles/PMC2820259/ /pubmed/20168976 http://dx.doi.org/10.1155/2009/148527 Text en Copyright © 2009 Simona Nicoara et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Nicoara, Simona Tonidandel, Loris Traldi, Pietro Watson, Jonathan Morgan, Geraint Popa, Ovidiu Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title | Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title_full | Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title_fullStr | Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title_full_unstemmed | Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title_short | Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method |
title_sort | determining the levels of volatile organic pollutants in urban air using a gas chromatography-mass spectrometry method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2820259/ https://www.ncbi.nlm.nih.gov/pubmed/20168976 http://dx.doi.org/10.1155/2009/148527 |
work_keys_str_mv | AT nicoarasimona determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod AT tonidandelloris determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod AT traldipietro determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod AT watsonjonathan determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod AT morgangeraint determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod AT popaovidiu determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod |