Cargando…

Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method

The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determ...

Descripción completa

Detalles Bibliográficos
Autores principales: Nicoara, Simona, Tonidandel, Loris, Traldi, Pietro, Watson, Jonathan, Morgan, Geraint, Popa, Ovidiu
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2820259/
https://www.ncbi.nlm.nih.gov/pubmed/20168976
http://dx.doi.org/10.1155/2009/148527
_version_ 1782177356544212992
author Nicoara, Simona
Tonidandel, Loris
Traldi, Pietro
Watson, Jonathan
Morgan, Geraint
Popa, Ovidiu
author_facet Nicoara, Simona
Tonidandel, Loris
Traldi, Pietro
Watson, Jonathan
Morgan, Geraint
Popa, Ovidiu
author_sort Nicoara, Simona
collection PubMed
description The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m(3) (B), 13–90 μg/m(3) (T), 7–50 μg/m(3) (E), 10–70 μg/m(3) (X-m,p), and 20–130 μg/m(3) (X-o). The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m(3) (Xo), 5/3 μg/m(3) (B, E, X-m,p), and of 3/1 μg/m(3) (T), respectively.
format Text
id pubmed-2820259
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-28202592010-02-18 Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method Nicoara, Simona Tonidandel, Loris Traldi, Pietro Watson, Jonathan Morgan, Geraint Popa, Ovidiu J Environ Public Health Research Article The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban centre in N-W Romania, with numerous and diversified road vehicles with internal combustion engines. The method is relatively inexpensive and simple and shows good precision and linearity in the ranges of 7–60 μg/m(3) (B), 13–90 μg/m(3) (T), 7–50 μg/m(3) (E), 10–70 μg/m(3) (X-m,p), and 20–130 μg/m(3) (X-o). The limits of quantitation/detection of the method LOQ/LOD are of 10/5 μg/m(3) (Xo), 5/3 μg/m(3) (B, E, X-m,p), and of 3/1 μg/m(3) (T), respectively. Hindawi Publishing Corporation 2009 2010-02-03 /pmc/articles/PMC2820259/ /pubmed/20168976 http://dx.doi.org/10.1155/2009/148527 Text en Copyright © 2009 Simona Nicoara et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Nicoara, Simona
Tonidandel, Loris
Traldi, Pietro
Watson, Jonathan
Morgan, Geraint
Popa, Ovidiu
Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title_full Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title_fullStr Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title_full_unstemmed Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title_short Determining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
title_sort determining the levels of volatile organic pollutants in urban air using a gas chromatography-mass spectrometry method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2820259/
https://www.ncbi.nlm.nih.gov/pubmed/20168976
http://dx.doi.org/10.1155/2009/148527
work_keys_str_mv AT nicoarasimona determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod
AT tonidandelloris determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod
AT traldipietro determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod
AT watsonjonathan determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod
AT morgangeraint determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod
AT popaovidiu determiningthelevelsofvolatileorganicpollutantsinurbanairusingagaschromatographymassspectrometrymethod