Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device

Background. We developed a completely closed system based on gravity separation without centrifugation steps for separation of whole blood. With this new system we compared quality and stability of the processed blood components (PRC and plasma) with respect to classical preparation. Furthermore the...

Descripción completa

Detalles Bibliográficos
Autores principales: Brune, T., Hannemann-Pohl, K., Nißle, K., Ecker, N., Garritsen, H.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2821640/
https://www.ncbi.nlm.nih.gov/pubmed/20169121
http://dx.doi.org/10.1155/2009/175234
_version_ 1782177457246306304
author Brune, T.
Hannemann-Pohl, K.
Nißle, K.
Ecker, N.
Garritsen, H.
author_facet Brune, T.
Hannemann-Pohl, K.
Nißle, K.
Ecker, N.
Garritsen, H.
author_sort Brune, T.
collection PubMed
description Background. We developed a completely closed system based on gravity separation without centrifugation steps for separation of whole blood. With this new system we compared quality and stability of the processed blood components (PRC and plasma) with respect to classical preparation. Furthermore the cost-effectiveness of this hollow fibre system was evaluated. Study Design and Methods. Whole blood collections of 15 regular blood donors were used for component preparation using the U shaped hollow fibre filter device. Results were compared to 15 whole blood preparations using centrifugation. The following parameters were evaluated: total hemoglobin, leukocyte counts, the serum concentration of total protein, lactate dehydrogenase (LDH) and potassium. Furthermore ATIII, vWF and F VIII were analyzed at different timepoints. Results. packed red cells: the data directly after separation and after 42 days of storage are in line with the guidelines of the council of Europe. Plasma. all plasma quality data are in line with the guidelines of the council of Europe for quality assurance of plasma, except for a low protein amount (factor 0.75). Conclusion. Separation of whole blood on a clinical scale in this new closed system is feasible, however the plasma protein content must be optimized.
format Text
id pubmed-2821640
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-28216402010-02-18 Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device Brune, T. Hannemann-Pohl, K. Nißle, K. Ecker, N. Garritsen, H. Adv Hematol Research Article Background. We developed a completely closed system based on gravity separation without centrifugation steps for separation of whole blood. With this new system we compared quality and stability of the processed blood components (PRC and plasma) with respect to classical preparation. Furthermore the cost-effectiveness of this hollow fibre system was evaluated. Study Design and Methods. Whole blood collections of 15 regular blood donors were used for component preparation using the U shaped hollow fibre filter device. Results were compared to 15 whole blood preparations using centrifugation. The following parameters were evaluated: total hemoglobin, leukocyte counts, the serum concentration of total protein, lactate dehydrogenase (LDH) and potassium. Furthermore ATIII, vWF and F VIII were analyzed at different timepoints. Results. packed red cells: the data directly after separation and after 42 days of storage are in line with the guidelines of the council of Europe. Plasma. all plasma quality data are in line with the guidelines of the council of Europe for quality assurance of plasma, except for a low protein amount (factor 0.75). Conclusion. Separation of whole blood on a clinical scale in this new closed system is feasible, however the plasma protein content must be optimized. Hindawi Publishing Corporation 2009 2010-02-04 /pmc/articles/PMC2821640/ /pubmed/20169121 http://dx.doi.org/10.1155/2009/175234 Text en Copyright © 2009 T. Brune et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Brune, T.
Hannemann-Pohl, K.
Nißle, K.
Ecker, N.
Garritsen, H.
Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title_full Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title_fullStr Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title_full_unstemmed Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title_short Quality, Stability, and Safety Data of Packed Red Cells and Plasma Processed by Gravity Separation Using a New Fully Integrated Hollow-Fibre Filter Device
title_sort quality, stability, and safety data of packed red cells and plasma processed by gravity separation using a new fully integrated hollow-fibre filter device
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2821640/
https://www.ncbi.nlm.nih.gov/pubmed/20169121
http://dx.doi.org/10.1155/2009/175234
work_keys_str_mv AT brunet qualitystabilityandsafetydataofpackedredcellsandplasmaprocessedbygravityseparationusinganewfullyintegratedhollowfibrefilterdevice
AT hannemannpohlk qualitystabilityandsafetydataofpackedredcellsandplasmaprocessedbygravityseparationusinganewfullyintegratedhollowfibrefilterdevice
AT nißlek qualitystabilityandsafetydataofpackedredcellsandplasmaprocessedbygravityseparationusinganewfullyintegratedhollowfibrefilterdevice
AT eckern qualitystabilityandsafetydataofpackedredcellsandplasmaprocessedbygravityseparationusinganewfullyintegratedhollowfibrefilterdevice
AT garritsenh qualitystabilityandsafetydataofpackedredcellsandplasmaprocessedbygravityseparationusinganewfullyintegratedhollowfibrefilterdevice