Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation

PURPOSE: Small field-of-view (FOV) dedicated cardiac SPECT systems suffer from truncated projection data. This results in (1) neglect of liver activity that otherwise could be used to estimate (and subsequently correct) the amount of scatter in the myocardium by model-based scatter correction, and (...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Jianbin, Verzijlbergen, Fred J., Viergever, Max A., Beekman, Freek J.
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2822234/
https://www.ncbi.nlm.nih.gov/pubmed/19722106
http://dx.doi.org/10.1007/s00259-009-1223-9
_version_ 1782177505892892672
author Xiao, Jianbin
Verzijlbergen, Fred J.
Viergever, Max A.
Beekman, Freek J.
author_facet Xiao, Jianbin
Verzijlbergen, Fred J.
Viergever, Max A.
Beekman, Freek J.
author_sort Xiao, Jianbin
collection PubMed
description PURPOSE: Small field-of-view (FOV) dedicated cardiac SPECT systems suffer from truncated projection data. This results in (1) neglect of liver activity that otherwise could be used to estimate (and subsequently correct) the amount of scatter in the myocardium by model-based scatter correction, and (2) distorted attenuation maps. In this study, we investigated to what extent truncation impacts attenuation correction and model-based scatter correction in the cases of (99m)Tc, (201)Tl, and simultaneous (99m)Tc/(201)Tl studies. In addition, we evaluated a simple correction method to mitigate the effects of truncation. METHODS: Digital thorax phantoms of different sizes were used to simulate the full FOV SPECT projections for (99m)Tc, (201)Tl, and simultaneous (99m)Tc/(201)Tl studies. Small FOV projections were obtained by artificially truncating the full FOV projections. Deviations from ideal heart positioning were simulated by axially shifting projections resulting in more severe liver truncation. Effects of truncation on SPECT images were tested for ordered subset (OS) expectation maximization reconstruction with (1) attenuation correction and detector response modelling (OS-AD), and (2) with additional Monte-Carlo-based scatter correction (OS-ADS). To correct truncation-induced artefacts, we axially extended truncated projections on both sides by duplicating pixel values on the projection edge. RESULTS: For both (99m)Tc and (201)Tl, differences in the reconstructed myocardium between full FOV and small FOV projections were negligible. In the nine myocardial segments, the maximum deviations of the average pixel values were 1.3% for OS-AD and 3.5% for OS-ADS. For the simultaneous (99m)Tc/(201)Tl studies, reconstructed (201)Tl SPECT images from full FOV and small FOV projections showed clearly different image profiles due to truncation. The maximum deviation in defected segments was found to be 49% in the worst-case scenario. However, artificially extending projections reduced deviations in defected segments to a few percent. CONCLUSION: Our results indicate that, for single isotope studies, using small FOV systems has little impact on attenuation correction and model-based scatter correction. For simultaneous (99m)Tc/(201)Tl studies, artificial projection extension almost fully eliminates the adverse effects of projection truncation.
format Text
id pubmed-2822234
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-28222342010-02-25 Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation Xiao, Jianbin Verzijlbergen, Fred J. Viergever, Max A. Beekman, Freek J. Eur J Nucl Med Mol Imaging Original Article PURPOSE: Small field-of-view (FOV) dedicated cardiac SPECT systems suffer from truncated projection data. This results in (1) neglect of liver activity that otherwise could be used to estimate (and subsequently correct) the amount of scatter in the myocardium by model-based scatter correction, and (2) distorted attenuation maps. In this study, we investigated to what extent truncation impacts attenuation correction and model-based scatter correction in the cases of (99m)Tc, (201)Tl, and simultaneous (99m)Tc/(201)Tl studies. In addition, we evaluated a simple correction method to mitigate the effects of truncation. METHODS: Digital thorax phantoms of different sizes were used to simulate the full FOV SPECT projections for (99m)Tc, (201)Tl, and simultaneous (99m)Tc/(201)Tl studies. Small FOV projections were obtained by artificially truncating the full FOV projections. Deviations from ideal heart positioning were simulated by axially shifting projections resulting in more severe liver truncation. Effects of truncation on SPECT images were tested for ordered subset (OS) expectation maximization reconstruction with (1) attenuation correction and detector response modelling (OS-AD), and (2) with additional Monte-Carlo-based scatter correction (OS-ADS). To correct truncation-induced artefacts, we axially extended truncated projections on both sides by duplicating pixel values on the projection edge. RESULTS: For both (99m)Tc and (201)Tl, differences in the reconstructed myocardium between full FOV and small FOV projections were negligible. In the nine myocardial segments, the maximum deviations of the average pixel values were 1.3% for OS-AD and 3.5% for OS-ADS. For the simultaneous (99m)Tc/(201)Tl studies, reconstructed (201)Tl SPECT images from full FOV and small FOV projections showed clearly different image profiles due to truncation. The maximum deviation in defected segments was found to be 49% in the worst-case scenario. However, artificially extending projections reduced deviations in defected segments to a few percent. CONCLUSION: Our results indicate that, for single isotope studies, using small FOV systems has little impact on attenuation correction and model-based scatter correction. For simultaneous (99m)Tc/(201)Tl studies, artificial projection extension almost fully eliminates the adverse effects of projection truncation. Springer-Verlag 2009-09-01 2010 /pmc/articles/PMC2822234/ /pubmed/19722106 http://dx.doi.org/10.1007/s00259-009-1223-9 Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Original Article
Xiao, Jianbin
Verzijlbergen, Fred J.
Viergever, Max A.
Beekman, Freek J.
Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title_full Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title_fullStr Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title_full_unstemmed Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title_short Small field-of-view dedicated cardiac SPECT systems: impact of projection truncation
title_sort small field-of-view dedicated cardiac spect systems: impact of projection truncation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2822234/
https://www.ncbi.nlm.nih.gov/pubmed/19722106
http://dx.doi.org/10.1007/s00259-009-1223-9
work_keys_str_mv AT xiaojianbin smallfieldofviewdedicatedcardiacspectsystemsimpactofprojectiontruncation
AT verzijlbergenfredj smallfieldofviewdedicatedcardiacspectsystemsimpactofprojectiontruncation
AT viergevermaxa smallfieldofviewdedicatedcardiacspectsystemsimpactofprojectiontruncation
AT beekmanfreekj smallfieldofviewdedicatedcardiacspectsystemsimpactofprojectiontruncation