Cargando…

Design and validation of Segment - freely available software for cardiovascular image analysis

BACKGROUND: Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware fo...

Descripción completa

Detalles Bibliográficos
Autores principales: Heiberg, Einar, Sjögren, Jane, Ugander, Martin, Carlsson, Marcus, Engblom, Henrik, Arheden, Håkan
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2822815/
https://www.ncbi.nlm.nih.gov/pubmed/20064248
http://dx.doi.org/10.1186/1471-2342-10-1
_version_ 1782177562134315008
author Heiberg, Einar
Sjögren, Jane
Ugander, Martin
Carlsson, Marcus
Engblom, Henrik
Arheden, Håkan
author_facet Heiberg, Einar
Sjögren, Jane
Ugander, Martin
Carlsson, Marcus
Engblom, Henrik
Arheden, Håkan
author_sort Heiberg, Einar
collection PubMed
description BACKGROUND: Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format. RESULTS: Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page http://segment.heiberg.se. CONCLUSIONS: Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited.
format Text
id pubmed-2822815
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28228152010-02-17 Design and validation of Segment - freely available software for cardiovascular image analysis Heiberg, Einar Sjögren, Jane Ugander, Martin Carlsson, Marcus Engblom, Henrik Arheden, Håkan BMC Med Imaging Software BACKGROUND: Commercially available software for cardiovascular image analysis often has limited functionality and frequently lacks the careful validation that is required for clinical studies. We have already implemented a cardiovascular image analysis software package and released it as freeware for the research community. However, it was distributed as a stand-alone application and other researchers could not extend it by writing their own custom image analysis algorithms. We believe that the work required to make a clinically applicable prototype can be reduced by making the software extensible, so that researchers can develop their own modules or improvements. Such an initiative might then serve as a bridge between image analysis research and cardiovascular research. The aim of this article is therefore to present the design and validation of a cardiovascular image analysis software package (Segment) and to announce its release in a source code format. RESULTS: Segment can be used for image analysis in magnetic resonance imaging (MRI), computed tomography (CT), single photon emission computed tomography (SPECT) and positron emission tomography (PET). Some of its main features include loading of DICOM images from all major scanner vendors, simultaneous display of multiple image stacks and plane intersections, automated segmentation of the left ventricle, quantification of MRI flow, tools for manual and general object segmentation, quantitative regional wall motion analysis, myocardial viability analysis and image fusion tools. Here we present an overview of the validation results and validation procedures for the functionality of the software. We describe a technique to ensure continued accuracy and validity of the software by implementing and using a test script that tests the functionality of the software and validates the output. The software has been made freely available for research purposes in a source code format on the project home page http://segment.heiberg.se. CONCLUSIONS: Segment is a well-validated comprehensive software package for cardiovascular image analysis. It is freely available for research purposes provided that relevant original research publications related to the software are cited. BioMed Central 2010-01-11 /pmc/articles/PMC2822815/ /pubmed/20064248 http://dx.doi.org/10.1186/1471-2342-10-1 Text en Copyright ©2010 Heiberg et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Software
Heiberg, Einar
Sjögren, Jane
Ugander, Martin
Carlsson, Marcus
Engblom, Henrik
Arheden, Håkan
Design and validation of Segment - freely available software for cardiovascular image analysis
title Design and validation of Segment - freely available software for cardiovascular image analysis
title_full Design and validation of Segment - freely available software for cardiovascular image analysis
title_fullStr Design and validation of Segment - freely available software for cardiovascular image analysis
title_full_unstemmed Design and validation of Segment - freely available software for cardiovascular image analysis
title_short Design and validation of Segment - freely available software for cardiovascular image analysis
title_sort design and validation of segment - freely available software for cardiovascular image analysis
topic Software
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2822815/
https://www.ncbi.nlm.nih.gov/pubmed/20064248
http://dx.doi.org/10.1186/1471-2342-10-1
work_keys_str_mv AT heibergeinar designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis
AT sjogrenjane designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis
AT ugandermartin designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis
AT carlssonmarcus designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis
AT engblomhenrik designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis
AT arhedenhakan designandvalidationofsegmentfreelyavailablesoftwareforcardiovascularimageanalysis