Cargando…

Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems

Background and purpose Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty...

Descripción completa

Detalles Bibliográficos
Autores principales: Albanese, Carlina V, Santori, Francesco S, Pavan, Laura, Learmonth, Ian D, Passariello, Roberto
Formato: Texto
Lenguaje:English
Publicado: Informa Healthcare 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2823205/
https://www.ncbi.nlm.nih.gov/pubmed/19562565
http://dx.doi.org/10.3109/17453670903074467
_version_ 1782177617188749312
author Albanese, Carlina V
Santori, Francesco S
Pavan, Laura
Learmonth, Ian D
Passariello, Roberto
author_facet Albanese, Carlina V
Santori, Francesco S
Pavan, Laura
Learmonth, Ian D
Passariello, Roberto
author_sort Albanese, Carlina V
collection PubMed
description Background and purpose Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on periprosthetic bone remodeling using a specifically developed protocol of analysis with 5 periprosthetic regions of interest (ROIs). Patients and methods Bone mineral density (BMD) was evaluated in 37 patients in the plateau stage, 3 years after THA. Two femoral implants featuring conceptually new designs and surgical technique were tested: types 1 and 2, characterized by extremely short stem and virtual absence of distal stem, respectively. Results We found that progressive shortening of the femoral stem produces more proximal loading, which effectively preserves metaphyseal bone stock and increases periprosthetic BMD in the medial ROIs over time. In the type 2 group, higher absolute BMD values were observed in medial ROIs 4 and 5. No differences were found in ROIs 1, 2, and 3. Interpretation This study shows the flexibility of DXA in adapting the protocol of periprosthetic analysis to the specific requirements of new implant designs, and it shows its high sensitivity in evaluation of the biological response of bone to changes in implant shape.
format Text
id pubmed-2823205
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-28232052010-02-18 Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems Albanese, Carlina V Santori, Francesco S Pavan, Laura Learmonth, Ian D Passariello, Roberto Acta Orthop Research Article Background and purpose Dual-energy X-ray absorptiometry (DXA) analysis of the 7 periprosthetic Gruen zones is the most commonly used protocol to evaluate bone remodeling after the implantation of conventional femoral stems. We assessed the value of DXA after cementless primary total hip arthroplasty (THA) by comparing the effect of progressive shortening of the stem of two femoral implants on periprosthetic bone remodeling using a specifically developed protocol of analysis with 5 periprosthetic regions of interest (ROIs). Patients and methods Bone mineral density (BMD) was evaluated in 37 patients in the plateau stage, 3 years after THA. Two femoral implants featuring conceptually new designs and surgical technique were tested: types 1 and 2, characterized by extremely short stem and virtual absence of distal stem, respectively. Results We found that progressive shortening of the femoral stem produces more proximal loading, which effectively preserves metaphyseal bone stock and increases periprosthetic BMD in the medial ROIs over time. In the type 2 group, higher absolute BMD values were observed in medial ROIs 4 and 5. No differences were found in ROIs 1, 2, and 3. Interpretation This study shows the flexibility of DXA in adapting the protocol of periprosthetic analysis to the specific requirements of new implant designs, and it shows its high sensitivity in evaluation of the biological response of bone to changes in implant shape. Informa Healthcare 2009-06-05 2009-06-01 /pmc/articles/PMC2823205/ /pubmed/19562565 http://dx.doi.org/10.3109/17453670903074467 Text en Copyright: © Nordic Orthopedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Research Article
Albanese, Carlina V
Santori, Francesco S
Pavan, Laura
Learmonth, Ian D
Passariello, Roberto
Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title_full Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title_fullStr Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title_full_unstemmed Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title_short Periprosthetic DXA after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
title_sort periprosthetic dxa after total hip arthroplasty with short vs. ultra-short custom-made femoral stems
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2823205/
https://www.ncbi.nlm.nih.gov/pubmed/19562565
http://dx.doi.org/10.3109/17453670903074467
work_keys_str_mv AT albanesecarlinav periprostheticdxaaftertotalhiparthroplastywithshortvsultrashortcustommadefemoralstems
AT santorifrancescos periprostheticdxaaftertotalhiparthroplastywithshortvsultrashortcustommadefemoralstems
AT pavanlaura periprostheticdxaaftertotalhiparthroplastywithshortvsultrashortcustommadefemoralstems
AT learmonthiand periprostheticdxaaftertotalhiparthroplastywithshortvsultrashortcustommadefemoralstems
AT passarielloroberto periprostheticdxaaftertotalhiparthroplastywithshortvsultrashortcustommadefemoralstems