Cargando…

Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients

Background and purpose There is considerable controversy about the treatment of complex, displaced proximal humeral fractures. Various types of head-preserving osteosynthesis have been suggested. This prospective case series was designed to evaluate the perioperative and early postoperative complica...

Descripción completa

Detalles Bibliográficos
Autores principales: Helwig, Peter, Bahrs, Christian, Epple, Björn, Oehm, Justus, Eingartner, Christoph, Weise, Kuno
Formato: Texto
Lenguaje:English
Publicado: Informa Healthcare 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2823244/
https://www.ncbi.nlm.nih.gov/pubmed/19297792
http://dx.doi.org/10.1080/17453670902807417
_version_ 1782177626434043904
author Helwig, Peter
Bahrs, Christian
Epple, Björn
Oehm, Justus
Eingartner, Christoph
Weise, Kuno
author_facet Helwig, Peter
Bahrs, Christian
Epple, Björn
Oehm, Justus
Eingartner, Christoph
Weise, Kuno
author_sort Helwig, Peter
collection PubMed
description Background and purpose There is considerable controversy about the treatment of complex, displaced proximal humeral fractures. Various types of head-preserving osteosynthesis have been suggested. This prospective case series was designed to evaluate the perioperative and early postoperative complications associated with fixed-angle implants and to record outcome after bone healing. Patients and methods Fractures of the proximal humerus were stabilized surgically in 87 patients (mean age 64 (16–93) years) by application of a fixed-angle plate (65 PHILOS, 22 T-LCP). There were 34 2-segment fractures, 42 3-segment fractures, and 11 4-segment fractures, including 7 dislocation fractures. Follow-up assessment after a minimum of 12 months was based on the Constant, UCLA, and DASH scores and on radiographs. Results Postoperative complications included soft tissue problems (n = 9), humeral head necrosis (n = 9), screw perforation (n = 11), secondary displacements (n = 14), and delayed fracture healing (n = 4). Treatment outcomes recorded on the various scores were very good in 60–82% of the cases. Interpretation Screw perforation of fixed-angle implants has replaced the complications of secondary displacement and implant loosening after using conventional plates. Even with the use of fixed-angle implants, fractures of the proximal humerus are associated with a high complication rate and sometimes poor outcome.
format Text
id pubmed-2823244
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Informa Healthcare
record_format MEDLINE/PubMed
spelling pubmed-28232442010-02-18 Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients Helwig, Peter Bahrs, Christian Epple, Björn Oehm, Justus Eingartner, Christoph Weise, Kuno Acta Orthop Research Article Background and purpose There is considerable controversy about the treatment of complex, displaced proximal humeral fractures. Various types of head-preserving osteosynthesis have been suggested. This prospective case series was designed to evaluate the perioperative and early postoperative complications associated with fixed-angle implants and to record outcome after bone healing. Patients and methods Fractures of the proximal humerus were stabilized surgically in 87 patients (mean age 64 (16–93) years) by application of a fixed-angle plate (65 PHILOS, 22 T-LCP). There were 34 2-segment fractures, 42 3-segment fractures, and 11 4-segment fractures, including 7 dislocation fractures. Follow-up assessment after a minimum of 12 months was based on the Constant, UCLA, and DASH scores and on radiographs. Results Postoperative complications included soft tissue problems (n = 9), humeral head necrosis (n = 9), screw perforation (n = 11), secondary displacements (n = 14), and delayed fracture healing (n = 4). Treatment outcomes recorded on the various scores were very good in 60–82% of the cases. Interpretation Screw perforation of fixed-angle implants has replaced the complications of secondary displacement and implant loosening after using conventional plates. Even with the use of fixed-angle implants, fractures of the proximal humerus are associated with a high complication rate and sometimes poor outcome. Informa Healthcare 2009-02-26 2009-02-01 /pmc/articles/PMC2823244/ /pubmed/19297792 http://dx.doi.org/10.1080/17453670902807417 Text en Copyright: © Nordic Orthopedic Federation http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.
spellingShingle Research Article
Helwig, Peter
Bahrs, Christian
Epple, Björn
Oehm, Justus
Eingartner, Christoph
Weise, Kuno
Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title_full Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title_fullStr Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title_full_unstemmed Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title_short Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: A prospective series of 87 patients
title_sort does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus?: a prospective series of 87 patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2823244/
https://www.ncbi.nlm.nih.gov/pubmed/19297792
http://dx.doi.org/10.1080/17453670902807417
work_keys_str_mv AT helwigpeter doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients
AT bahrschristian doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients
AT epplebjorn doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients
AT oehmjustus doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients
AT eingartnerchristoph doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients
AT weisekuno doesfixedangleplateosteosynthesissolvetheproblemsofafracturedproximalhumerusaprospectiveseriesof87patients