Cargando…

The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results

BACKGROUND: This study examined the results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft as a surgical technique for the patients who suffer from osteoarthritis of the knee with a genu varum deformity. METHODS: From March 2007 to August 2007,...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Su Chan, Jung, Kwang Am, Nam, Chang Hyun, Jung, Soong Hyun, Hwang, Seung Hyun
Formato: Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2824095/
https://www.ncbi.nlm.nih.gov/pubmed/20191001
http://dx.doi.org/10.4055/cios.2010.2.1.47
_version_ 1782177693432807424
author Lee, Su Chan
Jung, Kwang Am
Nam, Chang Hyun
Jung, Soong Hyun
Hwang, Seung Hyun
author_facet Lee, Su Chan
Jung, Kwang Am
Nam, Chang Hyun
Jung, Soong Hyun
Hwang, Seung Hyun
author_sort Lee, Su Chan
collection PubMed
description BACKGROUND: This study examined the results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft as a surgical technique for the patients who suffer from osteoarthritis of the knee with a genu varum deformity. METHODS: From March 2007 to August 2007, 33 patients (37 cases) with osteoarthritis of the knee and a genu varum deformity underwent a high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft. The patients were followed up for more than 1 year. Before and after surgery, the correction angle of the genu varum was measured by the lower extremity scannogram and the posterior tibial slope, the joint space distance and the time to bone union were evaluated. The functional factors were evaluated using the Knee Society Score. RESULTS: The average knee score and function score improved from 52.19 ± 11.82 to 92.49 ± 5.10 and 52.84 ± 6.23 to 89.05 ± 5.53, respectively (p < 0.001). According to the lower extremity scannogram, the mean preoperative varus angle was -1.86 ± 2.76°, and the average correction angle at the last follow-up was 10.93 ± 2.50° (p < 0.001). The tibial posterior slope before surgery and at the last follow-up were 8.20 ± 1.80° and 8.04 ± 1.30°, respectively (p = 0.437). The joint space distance increased from 4.05 ± 1.30 mm to 4.83 ± 1.33 mm (p < 0.001). The average time to complete bone union was 12.69 ± 1.5 weeks. CONCLUSIONS: An open wedge high tibial osteotomy using an Aescula open wedge plate and an allogeneic bone graft to treat osteoarthritis of the knee with a genu varum deformity showed good results for the precision of the correction angle, the time to bone union and the functional improvement.
format Text
id pubmed-2824095
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-28240952010-03-01 The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results Lee, Su Chan Jung, Kwang Am Nam, Chang Hyun Jung, Soong Hyun Hwang, Seung Hyun Clin Orthop Surg Original Article BACKGROUND: This study examined the results of open wedge high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft as a surgical technique for the patients who suffer from osteoarthritis of the knee with a genu varum deformity. METHODS: From March 2007 to August 2007, 33 patients (37 cases) with osteoarthritis of the knee and a genu varum deformity underwent a high tibial osteotomy with using an Aescula open wedge plate and an allogenic bone graft. The patients were followed up for more than 1 year. Before and after surgery, the correction angle of the genu varum was measured by the lower extremity scannogram and the posterior tibial slope, the joint space distance and the time to bone union were evaluated. The functional factors were evaluated using the Knee Society Score. RESULTS: The average knee score and function score improved from 52.19 ± 11.82 to 92.49 ± 5.10 and 52.84 ± 6.23 to 89.05 ± 5.53, respectively (p < 0.001). According to the lower extremity scannogram, the mean preoperative varus angle was -1.86 ± 2.76°, and the average correction angle at the last follow-up was 10.93 ± 2.50° (p < 0.001). The tibial posterior slope before surgery and at the last follow-up were 8.20 ± 1.80° and 8.04 ± 1.30°, respectively (p = 0.437). The joint space distance increased from 4.05 ± 1.30 mm to 4.83 ± 1.33 mm (p < 0.001). The average time to complete bone union was 12.69 ± 1.5 weeks. CONCLUSIONS: An open wedge high tibial osteotomy using an Aescula open wedge plate and an allogeneic bone graft to treat osteoarthritis of the knee with a genu varum deformity showed good results for the precision of the correction angle, the time to bone union and the functional improvement. The Korean Orthopaedic Association 2010-03 2010-02-04 /pmc/articles/PMC2824095/ /pubmed/20191001 http://dx.doi.org/10.4055/cios.2010.2.1.47 Text en Copyright © 2010 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Su Chan
Jung, Kwang Am
Nam, Chang Hyun
Jung, Soong Hyun
Hwang, Seung Hyun
The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title_full The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title_fullStr The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title_full_unstemmed The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title_short The Short-term Follow-up Results of Open Wedge High Tibial Osteotomy with Using an Aescula Open Wedge Plate and an Allogenic Bone Graft: The Minimum 1-Year Follow-up Results
title_sort short-term follow-up results of open wedge high tibial osteotomy with using an aescula open wedge plate and an allogenic bone graft: the minimum 1-year follow-up results
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2824095/
https://www.ncbi.nlm.nih.gov/pubmed/20191001
http://dx.doi.org/10.4055/cios.2010.2.1.47
work_keys_str_mv AT leesuchan theshorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT jungkwangam theshorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT namchanghyun theshorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT jungsoonghyun theshorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT hwangseunghyun theshorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT leesuchan shorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT jungkwangam shorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT namchanghyun shorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT jungsoonghyun shorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults
AT hwangseunghyun shorttermfollowupresultsofopenwedgehightibialosteotomywithusinganaesculaopenwedgeplateandanallogenicbonegrafttheminimum1yearfollowupresults