Cargando…

Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating

INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fract...

Descripción completa

Detalles Bibliográficos
Autores principales: Buijze, Geert A., Blankevoort, Leendert, Tuijthof, Gabriëlle J. M., Sierevelt, Inger N., Kloen, Peter
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826637/
https://www.ncbi.nlm.nih.gov/pubmed/19823857
http://dx.doi.org/10.1007/s00402-009-0980-z
_version_ 1782177872465625088
author Buijze, Geert A.
Blankevoort, Leendert
Tuijthof, Gabriëlle J. M.
Sierevelt, Inger N.
Kloen, Peter
author_facet Buijze, Geert A.
Blankevoort, Leendert
Tuijthof, Gabriëlle J. M.
Sierevelt, Inger N.
Kloen, Peter
author_sort Buijze, Geert A.
collection PubMed
description INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. MATERIALS AND METHODS: Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. RESULTS: There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. CONCLUSION: Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating technique.
format Text
id pubmed-2826637
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-28266372010-03-05 Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating Buijze, Geert A. Blankevoort, Leendert Tuijthof, Gabriëlle J. M. Sierevelt, Inger N. Kloen, Peter Arch Orthop Trauma Surg Orthopaedic Surgery INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. MATERIALS AND METHODS: Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. RESULTS: There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. CONCLUSION: Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating technique. Springer-Verlag 2009-10-13 2010 /pmc/articles/PMC2826637/ /pubmed/19823857 http://dx.doi.org/10.1007/s00402-009-0980-z Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Orthopaedic Surgery
Buijze, Geert A.
Blankevoort, Leendert
Tuijthof, Gabriëlle J. M.
Sierevelt, Inger N.
Kloen, Peter
Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title_full Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title_fullStr Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title_full_unstemmed Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title_short Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
title_sort biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
topic Orthopaedic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826637/
https://www.ncbi.nlm.nih.gov/pubmed/19823857
http://dx.doi.org/10.1007/s00402-009-0980-z
work_keys_str_mv AT buijzegeerta biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating
AT blankevoortleendert biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating
AT tuijthofgabriellejm biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating
AT siereveltingern biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating
AT kloenpeter biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating