Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating
INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fract...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826637/ https://www.ncbi.nlm.nih.gov/pubmed/19823857 http://dx.doi.org/10.1007/s00402-009-0980-z |
_version_ | 1782177872465625088 |
---|---|
author | Buijze, Geert A. Blankevoort, Leendert Tuijthof, Gabriëlle J. M. Sierevelt, Inger N. Kloen, Peter |
author_facet | Buijze, Geert A. Blankevoort, Leendert Tuijthof, Gabriëlle J. M. Sierevelt, Inger N. Kloen, Peter |
author_sort | Buijze, Geert A. |
collection | PubMed |
description | INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. MATERIALS AND METHODS: Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. RESULTS: There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. CONCLUSION: Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating technique. |
format | Text |
id | pubmed-2826637 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-28266372010-03-05 Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating Buijze, Geert A. Blankevoort, Leendert Tuijthof, Gabriëlle J. M. Sierevelt, Inger N. Kloen, Peter Arch Orthop Trauma Surg Orthopaedic Surgery INTRODUCTION: New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. MATERIALS AND METHODS: Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. RESULTS: There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. CONCLUSION: Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating technique. Springer-Verlag 2009-10-13 2010 /pmc/articles/PMC2826637/ /pubmed/19823857 http://dx.doi.org/10.1007/s00402-009-0980-z Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Orthopaedic Surgery Buijze, Geert A. Blankevoort, Leendert Tuijthof, Gabriëlle J. M. Sierevelt, Inger N. Kloen, Peter Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title | Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title_full | Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title_fullStr | Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title_full_unstemmed | Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title_short | Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
title_sort | biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating |
topic | Orthopaedic Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826637/ https://www.ncbi.nlm.nih.gov/pubmed/19823857 http://dx.doi.org/10.1007/s00402-009-0980-z |
work_keys_str_mv | AT buijzegeerta biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating AT blankevoortleendert biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating AT tuijthofgabriellejm biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating AT siereveltingern biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating AT kloenpeter biomechanicalevaluationoffixationofcomminutedolecranonfracturesonethirdtubularversuslockingcompressionplating |