Cargando…

Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach

Transcatheter balloon pulmonary valvuloplasty (BPV) is considered to be the treatment of choice for neonates with critical pulmonary valvar stenosis (PVS) or pulmonary valvar atresia with intact ventricular septum accompanied by reasonable right ventricular volume. The percutaneous femoral venous ac...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Gi-Beom, Bae, Eun-Jung, Noh, Chung-Il
Formato: Texto
Lenguaje:English
Publicado: The Korean Academy of Medical Sciences 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826727/
https://www.ncbi.nlm.nih.gov/pubmed/20191053
http://dx.doi.org/10.3346/jkms.2010.25.3.485
_version_ 1782177880526028800
author Kim, Gi-Beom
Bae, Eun-Jung
Noh, Chung-Il
author_facet Kim, Gi-Beom
Bae, Eun-Jung
Noh, Chung-Il
author_sort Kim, Gi-Beom
collection PubMed
description Transcatheter balloon pulmonary valvuloplasty (BPV) is considered to be the treatment of choice for neonates with critical pulmonary valvar stenosis (PVS) or pulmonary valvar atresia with intact ventricular septum accompanied by reasonable right ventricular volume. The percutaneous femoral venous access is the most preferred route for BPV in most cardiac centers. We report herein the case of a newborn baby with critical PVS with inferior vena cava interruption, severe tricuspid regurgitation and a severely enlarged right atrium. We tried BPV through the transumbilical approach with difficulty, but he was successfully treated with the assistance of a coronary artery guiding catheter.
format Text
id pubmed-2826727
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher The Korean Academy of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-28267272010-03-01 Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach Kim, Gi-Beom Bae, Eun-Jung Noh, Chung-Il J Korean Med Sci Case Report Transcatheter balloon pulmonary valvuloplasty (BPV) is considered to be the treatment of choice for neonates with critical pulmonary valvar stenosis (PVS) or pulmonary valvar atresia with intact ventricular septum accompanied by reasonable right ventricular volume. The percutaneous femoral venous access is the most preferred route for BPV in most cardiac centers. We report herein the case of a newborn baby with critical PVS with inferior vena cava interruption, severe tricuspid regurgitation and a severely enlarged right atrium. We tried BPV through the transumbilical approach with difficulty, but he was successfully treated with the assistance of a coronary artery guiding catheter. The Korean Academy of Medical Sciences 2010-03 2010-02-17 /pmc/articles/PMC2826727/ /pubmed/20191053 http://dx.doi.org/10.3346/jkms.2010.25.3.485 Text en © 2010 The Korean Academy of Medical Sciences. http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Kim, Gi-Beom
Bae, Eun-Jung
Noh, Chung-Il
Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title_full Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title_fullStr Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title_full_unstemmed Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title_short Balloon Valvuloplasty for Neonatal Critical Pulmonary Valvar Stenosis with IVC Interruption: Pitfalls of the Transumbilical Approach
title_sort balloon valvuloplasty for neonatal critical pulmonary valvar stenosis with ivc interruption: pitfalls of the transumbilical approach
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2826727/
https://www.ncbi.nlm.nih.gov/pubmed/20191053
http://dx.doi.org/10.3346/jkms.2010.25.3.485
work_keys_str_mv AT kimgibeom balloonvalvuloplastyforneonatalcriticalpulmonaryvalvarstenosiswithivcinterruptionpitfallsofthetransumbilicalapproach
AT baeeunjung balloonvalvuloplastyforneonatalcriticalpulmonaryvalvarstenosiswithivcinterruptionpitfallsofthetransumbilicalapproach
AT nohchungil balloonvalvuloplastyforneonatalcriticalpulmonaryvalvarstenosiswithivcinterruptionpitfallsofthetransumbilicalapproach