Cargando…

Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report

Limited literature is available on the reconstruction of the distal radius using prosthetic replacement following resection of a bone tumour. We present the first reported case, in the English literature, of the use of an entirely metal endoprosthesis for the reconstruction of the distal radius. Thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Gokaraju, Kishan, Sri-Ram, Kesavan, Donaldson, James, Parratt, Michael T. R., Blunn, Gordon W., Cannon, Steve R., Briggs, Timothy W. R.
Formato: Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2831197/
https://www.ncbi.nlm.nih.gov/pubmed/20204177
http://dx.doi.org/10.1155/2009/938295
_version_ 1782178224102440960
author Gokaraju, Kishan
Sri-Ram, Kesavan
Donaldson, James
Parratt, Michael T. R.
Blunn, Gordon W.
Cannon, Steve R.
Briggs, Timothy W. R.
author_facet Gokaraju, Kishan
Sri-Ram, Kesavan
Donaldson, James
Parratt, Michael T. R.
Blunn, Gordon W.
Cannon, Steve R.
Briggs, Timothy W. R.
author_sort Gokaraju, Kishan
collection PubMed
description Limited literature is available on the reconstruction of the distal radius using prosthetic replacement following resection of a bone tumour. We present the first reported case, in the English literature, of the use of an entirely metal endoprosthesis for the reconstruction of the distal radius. This case involves a 66-year-old male who was treated for giant cell tumour of the distal radius with surgical excision of the lesion and replacement of the defect using a predominantly titanium endoprosthesis. He was followed-up for 56 months following surgery and had a good functional outcome with no associated pain or complications. We propose that the use of a primarily titanium endoprosthesis for the reconstruction of a bone defect of the distal radius is a suitable alternative, providing good function of the forearm with satisfactory range of movement at the wrist and adequate pain relief.
format Text
id pubmed-2831197
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-28311972010-03-04 Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report Gokaraju, Kishan Sri-Ram, Kesavan Donaldson, James Parratt, Michael T. R. Blunn, Gordon W. Cannon, Steve R. Briggs, Timothy W. R. Sarcoma Case Report Limited literature is available on the reconstruction of the distal radius using prosthetic replacement following resection of a bone tumour. We present the first reported case, in the English literature, of the use of an entirely metal endoprosthesis for the reconstruction of the distal radius. This case involves a 66-year-old male who was treated for giant cell tumour of the distal radius with surgical excision of the lesion and replacement of the defect using a predominantly titanium endoprosthesis. He was followed-up for 56 months following surgery and had a good functional outcome with no associated pain or complications. We propose that the use of a primarily titanium endoprosthesis for the reconstruction of a bone defect of the distal radius is a suitable alternative, providing good function of the forearm with satisfactory range of movement at the wrist and adequate pain relief. Hindawi Publishing Corporation 2009 2010-03-02 /pmc/articles/PMC2831197/ /pubmed/20204177 http://dx.doi.org/10.1155/2009/938295 Text en Copyright © 2009 Kishan Gokaraju et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Gokaraju, Kishan
Sri-Ram, Kesavan
Donaldson, James
Parratt, Michael T. R.
Blunn, Gordon W.
Cannon, Steve R.
Briggs, Timothy W. R.
Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title_full Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title_fullStr Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title_full_unstemmed Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title_short Use of a Distal Radius Endoprosthesis Following Resection of a Bone Tumour: A Case Report
title_sort use of a distal radius endoprosthesis following resection of a bone tumour: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2831197/
https://www.ncbi.nlm.nih.gov/pubmed/20204177
http://dx.doi.org/10.1155/2009/938295
work_keys_str_mv AT gokarajukishan useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT sriramkesavan useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT donaldsonjames useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT parrattmichaeltr useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT blunngordonw useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT cannonstever useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport
AT briggstimothywr useofadistalradiusendoprosthesisfollowingresectionofabonetumouracasereport