Cargando…
Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2835637/ https://www.ncbi.nlm.nih.gov/pubmed/19802613 http://dx.doi.org/10.1007/s00330-009-1620-2 |
_version_ | 1782178638279475200 |
---|---|
author | Zwanenburg, Jaco J. M. Hendrikse, Jeroen Visser, Fredy Takahara, Taro Luijten, Peter R. |
author_facet | Zwanenburg, Jaco J. M. Hendrikse, Jeroen Visser, Fredy Takahara, Taro Luijten, Peter R. |
author_sort | Zwanenburg, Jaco J. M. |
collection | PubMed |
description | PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T). METHODS: FLAIR images of five healthy volunteers (age 24 ± 4 years, 4 male) were acquired at 1.5 T, 3 T and 7 T. Image homogeneity and visibility of normal brain structures were evaluated. SNR of grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) were measured in regions not affected by transmit field heterogeneity. RESULTS: The SNR (mean ± SD) at 7 T (GM 168 ± 15, WM 125 ± 11) increased slightly more than proportionally, compared with at 1.5 T (GM 30 ± 3, WM 22 ± 2) and 3 T (GM 62 ± 7, WM 44 ± 4). Relative contrast between GM and WM at 7 T (1.35 ± 0.07) was slightly less than at 3 T (1.42 ± 0.14) or 1.5 T (1.37 ± 0.07). Several major fibre bundles became visible at 7 T. One incidentally observed white matter lesion was well visible at all field strengths. CONCLUSION: Image homogeneity remains challenging and should be improved by future technical developments. FLAIR imaging at 7 T yields a high SNR,with better contrast for WM substructures and the iron-bearing basal ganglia, and has potential for good conspicuity of WM lesions. |
format | Text |
id | pubmed-2835637 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-28356372010-03-24 Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla Zwanenburg, Jaco J. M. Hendrikse, Jeroen Visser, Fredy Takahara, Taro Luijten, Peter R. Eur Radiol Magnetic Resonance PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T). METHODS: FLAIR images of five healthy volunteers (age 24 ± 4 years, 4 male) were acquired at 1.5 T, 3 T and 7 T. Image homogeneity and visibility of normal brain structures were evaluated. SNR of grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) were measured in regions not affected by transmit field heterogeneity. RESULTS: The SNR (mean ± SD) at 7 T (GM 168 ± 15, WM 125 ± 11) increased slightly more than proportionally, compared with at 1.5 T (GM 30 ± 3, WM 22 ± 2) and 3 T (GM 62 ± 7, WM 44 ± 4). Relative contrast between GM and WM at 7 T (1.35 ± 0.07) was slightly less than at 3 T (1.42 ± 0.14) or 1.5 T (1.37 ± 0.07). Several major fibre bundles became visible at 7 T. One incidentally observed white matter lesion was well visible at all field strengths. CONCLUSION: Image homogeneity remains challenging and should be improved by future technical developments. FLAIR imaging at 7 T yields a high SNR,with better contrast for WM substructures and the iron-bearing basal ganglia, and has potential for good conspicuity of WM lesions. Springer-Verlag 2009-10-03 2010 /pmc/articles/PMC2835637/ /pubmed/19802613 http://dx.doi.org/10.1007/s00330-009-1620-2 Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Magnetic Resonance Zwanenburg, Jaco J. M. Hendrikse, Jeroen Visser, Fredy Takahara, Taro Luijten, Peter R. Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title | Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title_full | Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title_fullStr | Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title_full_unstemmed | Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title_short | Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla |
title_sort | fluid attenuated inversion recovery (flair) mri at 7.0 tesla: comparison with 1.5 and 3.0 tesla |
topic | Magnetic Resonance |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2835637/ https://www.ncbi.nlm.nih.gov/pubmed/19802613 http://dx.doi.org/10.1007/s00330-009-1620-2 |
work_keys_str_mv | AT zwanenburgjacojm fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla AT hendriksejeroen fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla AT visserfredy fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla AT takaharataro fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla AT luijtenpeterr fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla |