Cargando…

Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla

PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T...

Descripción completa

Detalles Bibliográficos
Autores principales: Zwanenburg, Jaco J. M., Hendrikse, Jeroen, Visser, Fredy, Takahara, Taro, Luijten, Peter R.
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2835637/
https://www.ncbi.nlm.nih.gov/pubmed/19802613
http://dx.doi.org/10.1007/s00330-009-1620-2
_version_ 1782178638279475200
author Zwanenburg, Jaco J. M.
Hendrikse, Jeroen
Visser, Fredy
Takahara, Taro
Luijten, Peter R.
author_facet Zwanenburg, Jaco J. M.
Hendrikse, Jeroen
Visser, Fredy
Takahara, Taro
Luijten, Peter R.
author_sort Zwanenburg, Jaco J. M.
collection PubMed
description PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T). METHODS: FLAIR images of five healthy volunteers (age 24 ± 4 years, 4 male) were acquired at 1.5 T, 3 T and 7 T. Image homogeneity and visibility of normal brain structures were evaluated. SNR of grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) were measured in regions not affected by transmit field heterogeneity. RESULTS: The SNR (mean ± SD) at 7 T (GM 168 ± 15, WM 125 ± 11) increased slightly more than proportionally, compared with at 1.5 T (GM 30 ± 3, WM 22 ± 2) and 3 T (GM 62 ± 7, WM 44 ± 4). Relative contrast between GM and WM at 7 T (1.35 ± 0.07) was slightly less than at 3 T (1.42 ± 0.14) or 1.5 T (1.37 ± 0.07). Several major fibre bundles became visible at 7 T. One incidentally observed white matter lesion was well visible at all field strengths. CONCLUSION: Image homogeneity remains challenging and should be improved by future technical developments. FLAIR imaging at 7 T yields a high SNR,with better contrast for WM substructures and the iron-bearing basal ganglia, and has potential for good conspicuity of WM lesions.
format Text
id pubmed-2835637
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-28356372010-03-24 Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla Zwanenburg, Jaco J. M. Hendrikse, Jeroen Visser, Fredy Takahara, Taro Luijten, Peter R. Eur Radiol Magnetic Resonance PURPOSE: To assess fluid-attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) at three field strengths, regarding signal-to-noise ratio (SNR), contrast and signal homogeneity, in order to determine the potential gain and current challenges of FLAIR at ultra-high field strength (7 T). METHODS: FLAIR images of five healthy volunteers (age 24 ± 4 years, 4 male) were acquired at 1.5 T, 3 T and 7 T. Image homogeneity and visibility of normal brain structures were evaluated. SNR of grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) were measured in regions not affected by transmit field heterogeneity. RESULTS: The SNR (mean ± SD) at 7 T (GM 168 ± 15, WM 125 ± 11) increased slightly more than proportionally, compared with at 1.5 T (GM 30 ± 3, WM 22 ± 2) and 3 T (GM 62 ± 7, WM 44 ± 4). Relative contrast between GM and WM at 7 T (1.35 ± 0.07) was slightly less than at 3 T (1.42 ± 0.14) or 1.5 T (1.37 ± 0.07). Several major fibre bundles became visible at 7 T. One incidentally observed white matter lesion was well visible at all field strengths. CONCLUSION: Image homogeneity remains challenging and should be improved by future technical developments. FLAIR imaging at 7 T yields a high SNR,with better contrast for WM substructures and the iron-bearing basal ganglia, and has potential for good conspicuity of WM lesions. Springer-Verlag 2009-10-03 2010 /pmc/articles/PMC2835637/ /pubmed/19802613 http://dx.doi.org/10.1007/s00330-009-1620-2 Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Magnetic Resonance
Zwanenburg, Jaco J. M.
Hendrikse, Jeroen
Visser, Fredy
Takahara, Taro
Luijten, Peter R.
Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title_full Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title_fullStr Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title_full_unstemmed Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title_short Fluid attenuated inversion recovery (FLAIR) MRI at 7.0 Tesla: comparison with 1.5 and 3.0 Tesla
title_sort fluid attenuated inversion recovery (flair) mri at 7.0 tesla: comparison with 1.5 and 3.0 tesla
topic Magnetic Resonance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2835637/
https://www.ncbi.nlm.nih.gov/pubmed/19802613
http://dx.doi.org/10.1007/s00330-009-1620-2
work_keys_str_mv AT zwanenburgjacojm fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla
AT hendriksejeroen fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla
AT visserfredy fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla
AT takaharataro fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla
AT luijtenpeterr fluidattenuatedinversionrecoveryflairmriat70teslacomparisonwith15and30tesla