Cargando…

Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment

Owing to the labelling requirements of food and feed products containing materials derived from genetically modified organisms, quantitative detection methods have to be developed for this purpose, including the necessary certified reference materials and calibrator standards. To date, for most gene...

Descripción completa

Detalles Bibliográficos
Autores principales: Lievens, A., Bellocchi, G., De Bernardi, D., Moens, W., Savini, C., Mazzara, M., Van den Eede, G., Van den Bulcke, M.
Formato: Texto
Lenguaje:English
Publicado: Springer-Verlag 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2836459/
https://www.ncbi.nlm.nih.gov/pubmed/20016879
http://dx.doi.org/10.1007/s00216-009-3346-z
_version_ 1782178716630122496
author Lievens, A.
Bellocchi, G.
De Bernardi, D.
Moens, W.
Savini, C.
Mazzara, M.
Van den Eede, G.
Van den Bulcke, M.
author_facet Lievens, A.
Bellocchi, G.
De Bernardi, D.
Moens, W.
Savini, C.
Mazzara, M.
Van den Eede, G.
Van den Bulcke, M.
author_sort Lievens, A.
collection PubMed
description Owing to the labelling requirements of food and feed products containing materials derived from genetically modified organisms, quantitative detection methods have to be developed for this purpose, including the necessary certified reference materials and calibrator standards. To date, for most genetically modified organisms authorized in the European Union, certified reference materials derived from seed powders are being developed. Here, an assessment has been made on the feasibility of using plasmid DNA as an alternative calibrator for the quantitative detection of genetically modified organisms. For this, a dual-target plasmid, designated as pJANUS™-02-001, comprising part of a junction region of genetically modified soybean event GTS-40-3-2 and the endogenous soybean-specific lectin gene was constructed. The dynamic range, efficiency and limit of detection for the soybean event GTS-40-3-2 real-time quantitative polymerase chain reaction (Q-PCR) system described by Terry et al. (J AOAC Int 85(4):938–944, 2002) were shown to be similar for in house produced homozygous genomic DNA from leaf tissue of soybean event GTS-40-3-2 and for plasmid pJANUS™-02-001 DNA backgrounds. The performance of this real-time Q-PCR system using both types of DNA templates as calibrator standards in quantitative DNA analysis was further assessed in an interlaboratory trial. Statistical analysis and fuzzy-logic-based interpretation were performed on critical method parameters (as defined by the European Network of GMO Laboratories and the Community Reference Laboratory for GM Food and Feed guidelines) and demonstrated that the plasmid pJANUS™-02-001 DNA represents a valuable alternative to genomic DNA as a calibrator for the quantification of soybean event GTS-40-3-2 in food and feed products.
format Text
id pubmed-2836459
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Springer-Verlag
record_format MEDLINE/PubMed
spelling pubmed-28364592010-03-24 Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment Lievens, A. Bellocchi, G. De Bernardi, D. Moens, W. Savini, C. Mazzara, M. Van den Eede, G. Van den Bulcke, M. Anal Bioanal Chem Original Paper Owing to the labelling requirements of food and feed products containing materials derived from genetically modified organisms, quantitative detection methods have to be developed for this purpose, including the necessary certified reference materials and calibrator standards. To date, for most genetically modified organisms authorized in the European Union, certified reference materials derived from seed powders are being developed. Here, an assessment has been made on the feasibility of using plasmid DNA as an alternative calibrator for the quantitative detection of genetically modified organisms. For this, a dual-target plasmid, designated as pJANUS™-02-001, comprising part of a junction region of genetically modified soybean event GTS-40-3-2 and the endogenous soybean-specific lectin gene was constructed. The dynamic range, efficiency and limit of detection for the soybean event GTS-40-3-2 real-time quantitative polymerase chain reaction (Q-PCR) system described by Terry et al. (J AOAC Int 85(4):938–944, 2002) were shown to be similar for in house produced homozygous genomic DNA from leaf tissue of soybean event GTS-40-3-2 and for plasmid pJANUS™-02-001 DNA backgrounds. The performance of this real-time Q-PCR system using both types of DNA templates as calibrator standards in quantitative DNA analysis was further assessed in an interlaboratory trial. Statistical analysis and fuzzy-logic-based interpretation were performed on critical method parameters (as defined by the European Network of GMO Laboratories and the Community Reference Laboratory for GM Food and Feed guidelines) and demonstrated that the plasmid pJANUS™-02-001 DNA represents a valuable alternative to genomic DNA as a calibrator for the quantification of soybean event GTS-40-3-2 in food and feed products. Springer-Verlag 2009-12-17 2010 /pmc/articles/PMC2836459/ /pubmed/20016879 http://dx.doi.org/10.1007/s00216-009-3346-z Text en © The Author(s) 2009 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Original Paper
Lievens, A.
Bellocchi, G.
De Bernardi, D.
Moens, W.
Savini, C.
Mazzara, M.
Van den Eede, G.
Van den Bulcke, M.
Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title_full Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title_fullStr Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title_full_unstemmed Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title_short Use of pJANUS™-02-001 as a calibrator plasmid for Roundup Ready soybean event GTS-40-3-2 detection: an interlaboratory trial assessment
title_sort use of pjanus™-02-001 as a calibrator plasmid for roundup ready soybean event gts-40-3-2 detection: an interlaboratory trial assessment
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2836459/
https://www.ncbi.nlm.nih.gov/pubmed/20016879
http://dx.doi.org/10.1007/s00216-009-3346-z
work_keys_str_mv AT lievensa useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT bellocchig useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT debernardid useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT moensw useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT savinic useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT mazzaram useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT vandeneedeg useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment
AT vandenbulckem useofpjanus02001asacalibratorplasmidforroundupreadysoybeaneventgts4032detectionaninterlaboratorytrialassessment