Anterograde Removal of Broken Femoral Nails without Opening the Nonunion Site: A New Technique
OBJECTIVE: We describe a new technique for removing the distal fragments of broken intramedullary femoral nails without disturbing the nonunion site. METHODS: This technique involves the application of an AO distractor prior to the removal of the nail fragments, with subsequent removal of the proxim...
Autores principales: | de Amorim Cabrita, Henrique Antônio Berwanger, Malavolta, Eduardo Angeli, Teixeira, Otávio Vilhena Reis, Montenegro, Nei Botter, Duarte, Fernando Aires, Mattar, Rames |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2845768/ https://www.ncbi.nlm.nih.gov/pubmed/20360918 http://dx.doi.org/10.1590/S1807-59322010000300007 |
Ejemplares similares
-
Stuffing the nail: A simple technique for the extraction of a broken femoral nail
por: Lovell, Jane, et al.
Publicado: (2017) -
Retrograde intramedullary nailing for the treatment of femoral medial condyle fracture nonunion
por: Niikura, Takahiro, et al.
Publicado: (2015) -
Risk factors for nonunion after intramedullary nailing of subtrochanteric femoral fractures
por: Krappinger, Dietmar, et al.
Publicado: (2019) -
Reamed intramedullary exchange nailing: treatment of choice of aseptic femoral shaft nonunion
por: Hierholzer, Christian, et al.
Publicado: (2014) -
Surgical factors contributing to nonunion in femoral shaft fracture following intramedullary nailing
por: Ma, Yong-Gang, et al.
Publicado: (2016)