Cargando…

Choline PET based dose-painting in prostate cancer - Modelling of dose effects

BACKGROUND: Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for do...

Descripción completa

Detalles Bibliográficos
Autores principales: Niyazi, Maximilian, Bartenstein, Peter, Belka, Claus, Ganswindt, Ute
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2848061/
https://www.ncbi.nlm.nih.gov/pubmed/20298546
http://dx.doi.org/10.1186/1748-717X-5-23
_version_ 1782179642481836032
author Niyazi, Maximilian
Bartenstein, Peter
Belka, Claus
Ganswindt, Ute
author_facet Niyazi, Maximilian
Bartenstein, Peter
Belka, Claus
Ganswindt, Ute
author_sort Niyazi, Maximilian
collection PubMed
description BACKGROUND: Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. METHODS: Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. RESULTS: Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). DISCUSSION: Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the assumption of high detection rates and low initial TCP values the TCP gain has been shown to be relevant. CONCLUSIONS: Based on the employed assumptions, specific dose escalation to choline PET positive areas within the prostate may increase the local control rates. Due to the lack of exact PET sensitivity and prostate α/β parameter, no firm conclusions can be made. Small variations may completely abrogate the clinical benefit of a SIB based on choline PET imaging.
format Text
id pubmed-2848061
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28480612010-04-01 Choline PET based dose-painting in prostate cancer - Modelling of dose effects Niyazi, Maximilian Bartenstein, Peter Belka, Claus Ganswindt, Ute Radiat Oncol Research BACKGROUND: Several randomized trials have documented the value of radiation dose escalation in patients with prostate cancer, especially in patients with intermediate risk profile. Up to now dose escalation is usually applied to the whole prostate. IMRT and related techniques currently allow for dose escalation in sub-volumes of the organ. However, the sensitivity of the imaging modality and the fact that small islands of cancer are often dispersed within the whole organ may limit these approaches with regard to a clear clinical benefit. In order to assess potential effects of a dose escalation in certain sub-volumes based on choline PET imaging a mathematical dose-response model was developed. METHODS: Based on different assumptions for α/β, γ50, sensitivity and specificity of choline PET, the influence of the whole prostate and simultaneous integrated boost (SIB) dose on tumor control probability (TCP) was calculated. Based on the given heterogeneity of all potential variables certain representative permutations of the parameters were chosen and, subsequently, the influence on TCP was assessed. RESULTS: Using schedules with 74 Gy within the whole prostate and a SIB dose of 90 Gy the TCP increase ranged from 23.1% (high detection rate of choline PET, low whole prostate dose, high γ50/ASTRO definition for tumor control) to 1.4% TCP gain (low sensitivity of PET, high whole prostate dose, CN + 2 definition for tumor control) or even 0% in selected cases. The corresponding initial TCP values without integrated boost ranged from 67.3% to 100%. According to a large data set of intermediate-risk prostate cancer patients the resulting TCP gains ranged from 22.2% to 10.1% (ASTRO definition) or from 13.2% to 6.0% (CN + 2 definition). DISCUSSION: Although a simplified mathematical model was employed, the presented model allows for an estimation in how far given schedules are relevant for clinical practice. However, the benefit of a SIB based on choline PET seems less than intuitively expected. Only under the assumption of high detection rates and low initial TCP values the TCP gain has been shown to be relevant. CONCLUSIONS: Based on the employed assumptions, specific dose escalation to choline PET positive areas within the prostate may increase the local control rates. Due to the lack of exact PET sensitivity and prostate α/β parameter, no firm conclusions can be made. Small variations may completely abrogate the clinical benefit of a SIB based on choline PET imaging. BioMed Central 2010-03-18 /pmc/articles/PMC2848061/ /pubmed/20298546 http://dx.doi.org/10.1186/1748-717X-5-23 Text en Copyright ©2010 Niyazi et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Niyazi, Maximilian
Bartenstein, Peter
Belka, Claus
Ganswindt, Ute
Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title_full Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title_fullStr Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title_full_unstemmed Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title_short Choline PET based dose-painting in prostate cancer - Modelling of dose effects
title_sort choline pet based dose-painting in prostate cancer - modelling of dose effects
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2848061/
https://www.ncbi.nlm.nih.gov/pubmed/20298546
http://dx.doi.org/10.1186/1748-717X-5-23
work_keys_str_mv AT niyazimaximilian cholinepetbaseddosepaintinginprostatecancermodellingofdoseeffects
AT bartensteinpeter cholinepetbaseddosepaintinginprostatecancermodellingofdoseeffects
AT belkaclaus cholinepetbaseddosepaintinginprostatecancermodellingofdoseeffects
AT ganswindtute cholinepetbaseddosepaintinginprostatecancermodellingofdoseeffects