RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms
A simple, specific, accurate, and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of venlafaxine hydrochloride in tablet dosage forms. A Phenomenex Gemini C-18, 5 μm column having 250 × 4.6 mm i.d. in isocratic mode, with mobile pha...
Autores principales: | , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications
2008
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852052/ https://www.ncbi.nlm.nih.gov/pubmed/20390099 http://dx.doi.org/10.4103/0250-474X.40350 |
_version_ | 1782179912120008704 |
---|---|
author | Baldania, S. L. Bhatt, K. K. Mehta, R. S. Shah, D. A. Gandhi, Tejal R. |
author_facet | Baldania, S. L. Bhatt, K. K. Mehta, R. S. Shah, D. A. Gandhi, Tejal R. |
author_sort | Baldania, S. L. |
collection | PubMed |
description | A simple, specific, accurate, and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of venlafaxine hydrochloride in tablet dosage forms. A Phenomenex Gemini C-18, 5 μm column having 250 × 4.6 mm i.d. in isocratic mode, with mobile phase containing methanol: 0.05 M potassium dihydrogen orthophosphate (70:30, v/v; pH 6.2) was used. The flow rate was 1.0 ml/min and effluents were monitored at 226 nm. Carbamazepine was used as an internal standard. The retention time of venlafaxine hydrochloride and carbamazepine were 3.7 min and 5.3 min, respectively. The method was validated for specificity, linearity, accuracy, precision, limit of quantification, limit of detection, robustness and solution stability. Limit of detection and limit of quantification for estimation of venlafaxine hydrochloride were found to be 100 ng/ml and 300 ng/ml, respectively. Recoveries of venlafaxine hydrochloride in tablet formulations were found to be in the range of 99.02-101.68%. Proposed method was successfully applied for the quantitative determination of venlafaxine hydrochloride in tablet dosage forms. |
format | Text |
id | pubmed-2852052 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2008 |
publisher | Medknow Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-28520522010-04-13 RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms Baldania, S. L. Bhatt, K. K. Mehta, R. S. Shah, D. A. Gandhi, Tejal R. Indian J Pharm Sci Short Communication A simple, specific, accurate, and precise reverse phase high performance liquid chromatographic method was developed and validated for the estimation of venlafaxine hydrochloride in tablet dosage forms. A Phenomenex Gemini C-18, 5 μm column having 250 × 4.6 mm i.d. in isocratic mode, with mobile phase containing methanol: 0.05 M potassium dihydrogen orthophosphate (70:30, v/v; pH 6.2) was used. The flow rate was 1.0 ml/min and effluents were monitored at 226 nm. Carbamazepine was used as an internal standard. The retention time of venlafaxine hydrochloride and carbamazepine were 3.7 min and 5.3 min, respectively. The method was validated for specificity, linearity, accuracy, precision, limit of quantification, limit of detection, robustness and solution stability. Limit of detection and limit of quantification for estimation of venlafaxine hydrochloride were found to be 100 ng/ml and 300 ng/ml, respectively. Recoveries of venlafaxine hydrochloride in tablet formulations were found to be in the range of 99.02-101.68%. Proposed method was successfully applied for the quantitative determination of venlafaxine hydrochloride in tablet dosage forms. Medknow Publications 2008 /pmc/articles/PMC2852052/ /pubmed/20390099 http://dx.doi.org/10.4103/0250-474X.40350 Text en © Indian Journal of Pharmaceutical Sciences http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communication Baldania, S. L. Bhatt, K. K. Mehta, R. S. Shah, D. A. Gandhi, Tejal R. RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title | RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title_full | RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title_fullStr | RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title_full_unstemmed | RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title_short | RP-HPLC Estimation of Venlafaxine Hydrochloride in Tablet Dosage Forms |
title_sort | rp-hplc estimation of venlafaxine hydrochloride in tablet dosage forms |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852052/ https://www.ncbi.nlm.nih.gov/pubmed/20390099 http://dx.doi.org/10.4103/0250-474X.40350 |
work_keys_str_mv | AT baldaniasl rphplcestimationofvenlafaxinehydrochlorideintabletdosageforms AT bhattkk rphplcestimationofvenlafaxinehydrochlorideintabletdosageforms AT mehtars rphplcestimationofvenlafaxinehydrochlorideintabletdosageforms AT shahda rphplcestimationofvenlafaxinehydrochlorideintabletdosageforms AT gandhitejalr rphplcestimationofvenlafaxinehydrochlorideintabletdosageforms |