A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis

Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that of lumen contour, because of the limited IVUS resolution. The purpose of this study was to compare a...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Eun-Seok, Garcia-Garcia, Hector M., Serruys, Patrick W.
Formato: Texto
Lenguaje:English
Publicado: Springer Netherlands 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852593/
https://www.ncbi.nlm.nih.gov/pubmed/20063068
http://dx.doi.org/10.1007/s10554-009-9567-6
_version_ 1782179949718798336
author Shin, Eun-Seok
Garcia-Garcia, Hector M.
Serruys, Patrick W.
author_facet Shin, Eun-Seok
Garcia-Garcia, Hector M.
Serruys, Patrick W.
author_sort Shin, Eun-Seok
collection PubMed
description Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that of lumen contour, because of the limited IVUS resolution. The purpose of this study was to compare a new measurement method (Shin’s method) and the conventional measurement method for necrotic core and calcium content in atherosclerotic lesions using Virtual Histology-intravascular ultrasound (VH-IVUS). Fifty-seven patients with unstable angina who underwent elective percutaneous coronary intervention were included. Shin’s method focuses on catheter contour, instead of lumen contour, and vessel contour. Patients ages ranged from 46 to 88 years, and 34 were men. A total of 1,401 frames from 59 culprit lesions were assessed. There were no significant differences in the mean area and volume of necrotic core and dense calcium between the two methods. Correlation coefficients (R) were ≥0.99 for all above mentioned parameters (P < 0.001). Between methods, the absolute differences in mean area and volume of necrotic core were 0.02 ± 0.02 mm² and 0.34 ± 0.29 mm³, respectively, while for mean area and volume of dense calcium, the absolute differences were 0.04 ± 0.07 mm² and 0.36 ± 0.52 mm³, respectively. The reproducibility of Shin’s method was excellent. For area of the necrotic core and dense calcium, the means of the differences between the two measurements were nearly zero, and the reproducibility coefficients were within 1% of the means of the two measurements. Mean analysis time for both measurements was 26.8 ± 6.7 min/segment in the conventional method and 3.3 ± 0.6 min/segment in Shin’s method. Shin’s method for measurement of necrotic core and dense calcium using VH-IVUS demonstrated a good correlation with the conventional method and excellent reproducibility. Also, Shin’s method required a significantly shorter analysis time than the conventional method. Therefore, Shin’s method could replace the conventional method for necrotic core and calcium measurement in atherosclerotic lesions, and it might be useful in the catheterization laboratory for online clinical decision.
format Text
id pubmed-2852593
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-28525932010-04-19 A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis Shin, Eun-Seok Garcia-Garcia, Hector M. Serruys, Patrick W. Int J Cardiovasc Imaging Original Paper Although previous intravascular ultrasound (IVUS) radiofrequency-based analysis data showed acceptable reproducibility for plaque composition, measurements are not easily obtained, particularly that of lumen contour, because of the limited IVUS resolution. The purpose of this study was to compare a new measurement method (Shin’s method) and the conventional measurement method for necrotic core and calcium content in atherosclerotic lesions using Virtual Histology-intravascular ultrasound (VH-IVUS). Fifty-seven patients with unstable angina who underwent elective percutaneous coronary intervention were included. Shin’s method focuses on catheter contour, instead of lumen contour, and vessel contour. Patients ages ranged from 46 to 88 years, and 34 were men. A total of 1,401 frames from 59 culprit lesions were assessed. There were no significant differences in the mean area and volume of necrotic core and dense calcium between the two methods. Correlation coefficients (R) were ≥0.99 for all above mentioned parameters (P < 0.001). Between methods, the absolute differences in mean area and volume of necrotic core were 0.02 ± 0.02 mm² and 0.34 ± 0.29 mm³, respectively, while for mean area and volume of dense calcium, the absolute differences were 0.04 ± 0.07 mm² and 0.36 ± 0.52 mm³, respectively. The reproducibility of Shin’s method was excellent. For area of the necrotic core and dense calcium, the means of the differences between the two measurements were nearly zero, and the reproducibility coefficients were within 1% of the means of the two measurements. Mean analysis time for both measurements was 26.8 ± 6.7 min/segment in the conventional method and 3.3 ± 0.6 min/segment in Shin’s method. Shin’s method for measurement of necrotic core and dense calcium using VH-IVUS demonstrated a good correlation with the conventional method and excellent reproducibility. Also, Shin’s method required a significantly shorter analysis time than the conventional method. Therefore, Shin’s method could replace the conventional method for necrotic core and calcium measurement in atherosclerotic lesions, and it might be useful in the catheterization laboratory for online clinical decision. Springer Netherlands 2010-01-09 2010 /pmc/articles/PMC2852593/ /pubmed/20063068 http://dx.doi.org/10.1007/s10554-009-9567-6 Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
spellingShingle Original Paper
Shin, Eun-Seok
Garcia-Garcia, Hector M.
Serruys, Patrick W.
A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title_full A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title_fullStr A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title_full_unstemmed A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title_short A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
title_sort new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852593/
https://www.ncbi.nlm.nih.gov/pubmed/20063068
http://dx.doi.org/10.1007/s10554-009-9567-6
work_keys_str_mv AT shineunseok anewmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis
AT garciagarciahectorm anewmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis
AT serruyspatrickw anewmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis
AT shineunseok newmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis
AT garciagarciahectorm newmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis
AT serruyspatrickw newmethodtomeasurenecroticcoreandcalciumcontentincoronaryplaquesusingintravascularultrasoundradiofrequencybasedanalysis