Cargando…
Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography
BACKGROUND/AIMS: Common bile duct stones are associated with the extent of dilation of the common bile duct as well as its angulation. Multidetector computed tomography (MD CT) has a good resolution for the definition of the anatomical features of the common bile duct. METHODS: The multiplanar refor...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Society of Pancreatobiliary Diseases
2009
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852735/ https://www.ncbi.nlm.nih.gov/pubmed/20431765 http://dx.doi.org/10.5009/gnl.2009.3.4.306 |
_version_ | 1782179972927979520 |
---|---|
author | Park, Jin-Seok Lee, Don Haeng Jeong, Seok Cho, Soon Gu |
author_facet | Park, Jin-Seok Lee, Don Haeng Jeong, Seok Cho, Soon Gu |
author_sort | Park, Jin-Seok |
collection | PubMed |
description | BACKGROUND/AIMS: Common bile duct stones are associated with the extent of dilation of the common bile duct as well as its angulation. Multidetector computed tomography (MD CT) has a good resolution for the definition of the anatomical features of the common bile duct. METHODS: The multiplanar reformation images of 398 patients that underwent multidetector CT for the diagnosis of disorders not related to the bile duct were examined. The diameter and angulation were categorized by gender and age. RESULTS: The average diameter and angulation of the common bile duct was 6.7 mm and 132.6°. There was a statistically significant correlation between age and the common bile duct diameter. The Pearson correlation analysis for age and diameter resulted in a value of 0.415 (p<0.001). And the common bile duct (CBD) diameter in people older than 51 years of age showed a significant difference compared to the subjects younger than 50 years of age (p<0.01). However, the degree of angulation has no correlation with age. CONCLUSIONS: We suggest that CBD diameters in patients more than 50 years of age can be more than 7 mm and be within normal limits. |
format | Text |
id | pubmed-2852735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2009 |
publisher | The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Society of Pancreatobiliary Diseases |
record_format | MEDLINE/PubMed |
spelling | pubmed-28527352010-04-29 Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography Park, Jin-Seok Lee, Don Haeng Jeong, Seok Cho, Soon Gu Gut Liver Original Article BACKGROUND/AIMS: Common bile duct stones are associated with the extent of dilation of the common bile duct as well as its angulation. Multidetector computed tomography (MD CT) has a good resolution for the definition of the anatomical features of the common bile duct. METHODS: The multiplanar reformation images of 398 patients that underwent multidetector CT for the diagnosis of disorders not related to the bile duct were examined. The diameter and angulation were categorized by gender and age. RESULTS: The average diameter and angulation of the common bile duct was 6.7 mm and 132.6°. There was a statistically significant correlation between age and the common bile duct diameter. The Pearson correlation analysis for age and diameter resulted in a value of 0.415 (p<0.001). And the common bile duct (CBD) diameter in people older than 51 years of age showed a significant difference compared to the subjects younger than 50 years of age (p<0.01). However, the degree of angulation has no correlation with age. CONCLUSIONS: We suggest that CBD diameters in patients more than 50 years of age can be more than 7 mm and be within normal limits. The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Society of Pancreatobiliary Diseases 2009-12 2009-12-31 /pmc/articles/PMC2852735/ /pubmed/20431765 http://dx.doi.org/10.5009/gnl.2009.3.4.306 Text en Copyright © 2009 The Korean Society of Gastroenterology; the Korean Society of Gastrointestinal Endoscopy; the Korean Association for the Study of the Liver; the Korean Society of Neurogastroenterology and Motility; Korean Association for the Study of Intestinal Diseases; Korean College of Helicobacter and Upper Gastrointestinal Research; Korean Society of Pancreatobiliary Diseases |
spellingShingle | Original Article Park, Jin-Seok Lee, Don Haeng Jeong, Seok Cho, Soon Gu Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title | Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title_full | Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title_fullStr | Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title_full_unstemmed | Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title_short | Determination of Diameter and Angulation of the Normal Common Bile Duct using Multidetector Computed Tomography |
title_sort | determination of diameter and angulation of the normal common bile duct using multidetector computed tomography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2852735/ https://www.ncbi.nlm.nih.gov/pubmed/20431765 http://dx.doi.org/10.5009/gnl.2009.3.4.306 |
work_keys_str_mv | AT parkjinseok determinationofdiameterandangulationofthenormalcommonbileductusingmultidetectorcomputedtomography AT leedonhaeng determinationofdiameterandangulationofthenormalcommonbileductusingmultidetectorcomputedtomography AT jeongseok determinationofdiameterandangulationofthenormalcommonbileductusingmultidetectorcomputedtomography AT chosoongu determinationofdiameterandangulationofthenormalcommonbileductusingmultidetectorcomputedtomography |