Cargando…
Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report
Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and d...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2853531/ https://www.ncbi.nlm.nih.gov/pubmed/20350310 http://dx.doi.org/10.1186/1749-8090-5-18 |
_version_ | 1782180038834126848 |
---|---|
author | Saeed, Omar Williams, Byron R Ku, Melvin Lattouf, Omar M |
author_facet | Saeed, Omar Williams, Byron R Ku, Melvin Lattouf, Omar M |
author_sort | Saeed, Omar |
collection | PubMed |
description | Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and decreased exercise tolerance. Echocardiography revealed severe mitral regurgitation (MR), thrombosis of the posterior mitral leaflet, left atrial (LA) mural thrombus and a depressed left ventricular ejection fraction of twenty-five percent. Given severe clot burden and decompensated heart failure (New York Heart Association - NYHA class III) repeat sternotomy was done to replace the bioprosthetic mitral valve and remove LA mural thrombus. MR was resolved postoperatively. This brief report further reviews promoting factors, established guidelines and management strategies of bioprosthetic valve thrombosis. |
format | Text |
id | pubmed-2853531 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-28535312010-04-13 Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report Saeed, Omar Williams, Byron R Ku, Melvin Lattouf, Omar M J Cardiothorac Surg Case report Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and decreased exercise tolerance. Echocardiography revealed severe mitral regurgitation (MR), thrombosis of the posterior mitral leaflet, left atrial (LA) mural thrombus and a depressed left ventricular ejection fraction of twenty-five percent. Given severe clot burden and decompensated heart failure (New York Heart Association - NYHA class III) repeat sternotomy was done to replace the bioprosthetic mitral valve and remove LA mural thrombus. MR was resolved postoperatively. This brief report further reviews promoting factors, established guidelines and management strategies of bioprosthetic valve thrombosis. BioMed Central 2010-03-29 /pmc/articles/PMC2853531/ /pubmed/20350310 http://dx.doi.org/10.1186/1749-8090-5-18 Text en Copyright ©2010 Saeed et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case report Saeed, Omar Williams, Byron R Ku, Melvin Lattouf, Omar M Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title | Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title_full | Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title_fullStr | Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title_full_unstemmed | Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title_short | Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report |
title_sort | bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative maze procedure: a case report |
topic | Case report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2853531/ https://www.ncbi.nlm.nih.gov/pubmed/20350310 http://dx.doi.org/10.1186/1749-8090-5-18 |
work_keys_str_mv | AT saeedomar bioprostheticmitralvalvethrombosislessthanoneyearafterreplacementandanablativemazeprocedureacasereport AT williamsbyronr bioprostheticmitralvalvethrombosislessthanoneyearafterreplacementandanablativemazeprocedureacasereport AT kumelvin bioprostheticmitralvalvethrombosislessthanoneyearafterreplacementandanablativemazeprocedureacasereport AT lattoufomarm bioprostheticmitralvalvethrombosislessthanoneyearafterreplacementandanablativemazeprocedureacasereport |