Cargando…

Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users

BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users mas...

Descripción completa

Detalles Bibliográficos
Autores principales: Anderberg, Magnus, Larsson, Johan, Kockum, Christina C, Arnbjörnsson, Einar
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2857839/
https://www.ncbi.nlm.nih.gov/pubmed/20370924
http://dx.doi.org/10.1186/1750-1164-4-3
_version_ 1782180349510418432
author Anderberg, Magnus
Larsson, Johan
Kockum, Christina C
Arnbjörnsson, Einar
author_facet Anderberg, Magnus
Larsson, Johan
Kockum, Christina C
Arnbjörnsson, Einar
author_sort Anderberg, Magnus
collection PubMed
description BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users master surgical tasks quicker with the robot-assisted laparoscopy technique than with the conventional laparoscopy technique. METHODS: 20 subjects, with no prior surgical experience, performed three different surgical tasks in a standardized experimental setting, repeated four times with each of the RL and CL techniques. Speed and accuracy were measured. A cross-over technique was used to eliminate gender bias and the experience gained by carrying out the first part of the study. RESULTS: The task "tie a knot" was performed faster with the RL technique than with CL. Furthermore, shorter operating times were observed when changing from CL to RL. There were no time differences for the tasks of grabbing the needle and continuous suturing between the two operating techniques. Gender did not influence the results. CONCLUSION: The more advanced task of tying a knot was performed faster using the RL technique than with CL. Simpler surgical interventions were performed equally fast with either technique. Technical skills acquired during the use of CL were transferred to the RL technique. The lack of tactile feedback in RL seemed to matter. There were no differences between males and females.
format Text
id pubmed-2857839
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28578392010-04-22 Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users Anderberg, Magnus Larsson, Johan Kockum, Christina C Arnbjörnsson, Einar Ann Surg Innov Res Research article BACKGROUND: Robot-assisted laparoscopy (RL) is used in a wide range of operative interventions, but the advantage of this technique over conventional laparoscopy (CL) remains unclear. Studies comparing RL and CL are scarce. The present study was performed to test the hypothesis that maiden users master surgical tasks quicker with the robot-assisted laparoscopy technique than with the conventional laparoscopy technique. METHODS: 20 subjects, with no prior surgical experience, performed three different surgical tasks in a standardized experimental setting, repeated four times with each of the RL and CL techniques. Speed and accuracy were measured. A cross-over technique was used to eliminate gender bias and the experience gained by carrying out the first part of the study. RESULTS: The task "tie a knot" was performed faster with the RL technique than with CL. Furthermore, shorter operating times were observed when changing from CL to RL. There were no time differences for the tasks of grabbing the needle and continuous suturing between the two operating techniques. Gender did not influence the results. CONCLUSION: The more advanced task of tying a knot was performed faster using the RL technique than with CL. Simpler surgical interventions were performed equally fast with either technique. Technical skills acquired during the use of CL were transferred to the RL technique. The lack of tactile feedback in RL seemed to matter. There were no differences between males and females. BioMed Central 2010-04-06 /pmc/articles/PMC2857839/ /pubmed/20370924 http://dx.doi.org/10.1186/1750-1164-4-3 Text en Copyright ©2010 Anderberg et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research article
Anderberg, Magnus
Larsson, Johan
Kockum, Christina C
Arnbjörnsson, Einar
Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title_full Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title_fullStr Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title_full_unstemmed Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title_short Robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
title_sort robotics versus laparoscopy - an experimental study of the transfer effect in maiden users
topic Research article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2857839/
https://www.ncbi.nlm.nih.gov/pubmed/20370924
http://dx.doi.org/10.1186/1750-1164-4-3
work_keys_str_mv AT anderbergmagnus roboticsversuslaparoscopyanexperimentalstudyofthetransfereffectinmaidenusers
AT larssonjohan roboticsversuslaparoscopyanexperimentalstudyofthetransfereffectinmaidenusers
AT kockumchristinac roboticsversuslaparoscopyanexperimentalstudyofthetransfereffectinmaidenusers
AT arnbjornssoneinar roboticsversuslaparoscopyanexperimentalstudyofthetransfereffectinmaidenusers