Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a tradition...
Autores principales: | , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
SAGE-Hindawi Access to Research
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2860198/ https://www.ncbi.nlm.nih.gov/pubmed/20445783 http://dx.doi.org/10.4061/2010/418596 |
_version_ | 1782180566067576832 |
---|---|
author | Stoskopf, Michael K. Mulcahy, Daniel M. Esler, Daniel |
author_facet | Stoskopf, Michael K. Mulcahy, Daniel M. Esler, Daniel |
author_sort | Stoskopf, Michael K. |
collection | PubMed |
description | A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values (N = 82) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L (N = 88; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk. |
format | Text |
id | pubmed-2860198 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | SAGE-Hindawi Access to Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-28601982010-05-05 Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus Stoskopf, Michael K. Mulcahy, Daniel M. Esler, Daniel Vet Med Int Research Article A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values (N = 82) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L (N = 88; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk. SAGE-Hindawi Access to Research 2010-02-22 /pmc/articles/PMC2860198/ /pubmed/20445783 http://dx.doi.org/10.4061/2010/418596 Text en Copyright © 2010 Michael K. Stoskopf et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Stoskopf, Michael K. Mulcahy, Daniel M. Esler, Daniel Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus |
title | Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
|
title_full | Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
|
title_fullStr | Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
|
title_full_unstemmed | Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
|
title_short | Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus
|
title_sort | evaluation of a portable automated serum chemistry analyzer for field assessment of harlequin ducks, histrionicus histrionicus |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2860198/ https://www.ncbi.nlm.nih.gov/pubmed/20445783 http://dx.doi.org/10.4061/2010/418596 |
work_keys_str_mv | AT stoskopfmichaelk evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus AT mulcahydanielm evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus AT eslerdaniel evaluationofaportableautomatedserumchemistryanalyzerforfieldassessmentofharlequinduckshistrionicushistrionicus |