Cargando…

Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

PURPOSE: The geometry of the proximal femur is one of the important factors for choosing the suitable stem. We have been applied cemented collarless polished tapered (CPT) stem to the patients with small femur. Radiographic evaluation was performed to access the clinical feature of the stem in early...

Descripción completa

Detalles Bibliográficos
Autores principales: Dairaku, Katsuyuki, Ishii, Masaji, Kobayashi, Shinji, Kawaji, Hiroyuki, Sasaki, Kan, Takakubo, Yuya, Takagi, Michiaki
Formato: Texto
Lenguaje:English
Publicado: Bentham Open 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2864431/
https://www.ncbi.nlm.nih.gov/pubmed/20448819
http://dx.doi.org/10.2174/1874325001004010147
_version_ 1782180779382538240
author Dairaku, Katsuyuki
Ishii, Masaji
Kobayashi, Shinji
Kawaji, Hiroyuki
Sasaki, Kan
Takakubo, Yuya
Takagi, Michiaki
author_facet Dairaku, Katsuyuki
Ishii, Masaji
Kobayashi, Shinji
Kawaji, Hiroyuki
Sasaki, Kan
Takakubo, Yuya
Takagi, Michiaki
author_sort Dairaku, Katsuyuki
collection PubMed
description PURPOSE: The geometry of the proximal femur is one of the important factors for choosing the suitable stem. We have been applied cemented collarless polished tapered (CPT) stem to the patients with small femur. Radiographic evaluation was performed to access the clinical feature of the stem in early stage of the follow-up. METHODS: One hundred total hip arthroplasties with CPT system were performed between October 2004 to February 2006. This study focused on the 53 cases to whom size 1 or smaller sized stem were implanted, and its post-operative period was 41 months (30-46 months). Morphologic classification of preoperative proximal femur, stem alignment, thickness of the cement mantle, cementing technique, subsidence of the stem, improvement in the bone-cement interface, and stress shielding were assessed. RESULTS: The size of the inserted stem was X-SMALL in one case, SMALL in two cases, SIZE 0 in 12 cases, and SIZE 1 in 38 cases. Canal shape of proximal femur was stovepipe type in five cases, normal type in 43 cases, and champagne-flute type in five cases. There was no subsidence in eight cases. 44 stems subsided within 1 mm, one stem subsided 1 to 2 mm, and no stem subsided over 2 mm. In 39 of 45 cases, subsidence was appeared within six months after operation. Marked progressive and excessive subsidence was not seen after the two years of follow-up. CONCLUSIONS: Short term radiographic results of THA with CPT stem to small femur were satisfactory with less unfavorable radiographic findings, which imply contribution to longer survivorship of the stem.
format Text
id pubmed-2864431
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-28644312010-05-06 Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal Dairaku, Katsuyuki Ishii, Masaji Kobayashi, Shinji Kawaji, Hiroyuki Sasaki, Kan Takakubo, Yuya Takagi, Michiaki Open Orthop J Article PURPOSE: The geometry of the proximal femur is one of the important factors for choosing the suitable stem. We have been applied cemented collarless polished tapered (CPT) stem to the patients with small femur. Radiographic evaluation was performed to access the clinical feature of the stem in early stage of the follow-up. METHODS: One hundred total hip arthroplasties with CPT system were performed between October 2004 to February 2006. This study focused on the 53 cases to whom size 1 or smaller sized stem were implanted, and its post-operative period was 41 months (30-46 months). Morphologic classification of preoperative proximal femur, stem alignment, thickness of the cement mantle, cementing technique, subsidence of the stem, improvement in the bone-cement interface, and stress shielding were assessed. RESULTS: The size of the inserted stem was X-SMALL in one case, SMALL in two cases, SIZE 0 in 12 cases, and SIZE 1 in 38 cases. Canal shape of proximal femur was stovepipe type in five cases, normal type in 43 cases, and champagne-flute type in five cases. There was no subsidence in eight cases. 44 stems subsided within 1 mm, one stem subsided 1 to 2 mm, and no stem subsided over 2 mm. In 39 of 45 cases, subsidence was appeared within six months after operation. Marked progressive and excessive subsidence was not seen after the two years of follow-up. CONCLUSIONS: Short term radiographic results of THA with CPT stem to small femur were satisfactory with less unfavorable radiographic findings, which imply contribution to longer survivorship of the stem. Bentham Open 2010-03-16 /pmc/articles/PMC2864431/ /pubmed/20448819 http://dx.doi.org/10.2174/1874325001004010147 Text en © Dairaku et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Dairaku, Katsuyuki
Ishii, Masaji
Kobayashi, Shinji
Kawaji, Hiroyuki
Sasaki, Kan
Takakubo, Yuya
Takagi, Michiaki
Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title_full Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title_fullStr Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title_full_unstemmed Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title_short Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal
title_sort initial evaluation on subsidence of cemented collarless polished tapered stem applied to the patients with narrow femoral medullar canal
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2864431/
https://www.ncbi.nlm.nih.gov/pubmed/20448819
http://dx.doi.org/10.2174/1874325001004010147
work_keys_str_mv AT dairakukatsuyuki initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT ishiimasaji initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT kobayashishinji initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT kawajihiroyuki initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT sasakikan initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT takakuboyuya initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal
AT takagimichiaki initialevaluationonsubsidenceofcementedcollarlesspolishedtaperedstemappliedtothepatientswithnarrowfemoralmedullarcanal