Cargando…
Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear
BACKGROUND: The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS: Between January 2007 and July 2007, fifty-one shoulders underwent arthroscopic suture bridge repair for full thickness rotator cuff tears. The...
Autores principales: | , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
The Korean Orthopaedic Association
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2867195/ https://www.ncbi.nlm.nih.gov/pubmed/20514268 http://dx.doi.org/10.4055/cios.2010.2.2.105 |
_version_ | 1782180972639289344 |
---|---|
author | Yi, Jin Woong Cho, Nam Su Cho, Seung Hyun Rhee, Yong Girl |
author_facet | Yi, Jin Woong Cho, Nam Su Cho, Seung Hyun Rhee, Yong Girl |
author_sort | Yi, Jin Woong |
collection | PubMed |
description | BACKGROUND: The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS: Between January 2007 and July 2007, fifty-one shoulders underwent arthroscopic suture bridge repair for full thickness rotator cuff tears. The average age at the time of surgery was 57.1 years old, and the mean follow-up period was 15.4 months. RESULTS: At the last follow-up, the pain at rest improved from 2.2 preoperatively to 0.23 postoperatively and the pain during motion improved from 6.3 preoperatively to 1.8 postoperatively (p < 0.001 and p < 0.001, respectively). The range of active forward flexion improved from 138.4° to 154.6°, and the muscle power improved from 4.9 kg to 6.0 kg (p = 0.04 and 0.019, respectively). The clinical results showed no significant difference according to the preoperative tear size and the extent of fatty degeneration, but imaging study showed a statistical relation between retear and fatty degeneration. The average Constant score improved from 73.2 to 83.79, and the average University of California at Los Angeles score changed from 18.2 to 29.6 with 7 excellent, 41 good and 3 poor results (p < 0.001 and p = 0.003, respectively). CONCLUSIONS: The arthroscopic suture bridge repair technique for rotator cuff tears may be an operative method for which a patient can expect to achieve clinical improvement regardless of the preoperative tear size and the extent of fatty degeneration. |
format | Text |
id | pubmed-2867195 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | The Korean Orthopaedic Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-28671952010-06-01 Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear Yi, Jin Woong Cho, Nam Su Cho, Seung Hyun Rhee, Yong Girl Clin Orthop Surg Original Article BACKGROUND: The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS: Between January 2007 and July 2007, fifty-one shoulders underwent arthroscopic suture bridge repair for full thickness rotator cuff tears. The average age at the time of surgery was 57.1 years old, and the mean follow-up period was 15.4 months. RESULTS: At the last follow-up, the pain at rest improved from 2.2 preoperatively to 0.23 postoperatively and the pain during motion improved from 6.3 preoperatively to 1.8 postoperatively (p < 0.001 and p < 0.001, respectively). The range of active forward flexion improved from 138.4° to 154.6°, and the muscle power improved from 4.9 kg to 6.0 kg (p = 0.04 and 0.019, respectively). The clinical results showed no significant difference according to the preoperative tear size and the extent of fatty degeneration, but imaging study showed a statistical relation between retear and fatty degeneration. The average Constant score improved from 73.2 to 83.79, and the average University of California at Los Angeles score changed from 18.2 to 29.6 with 7 excellent, 41 good and 3 poor results (p < 0.001 and p = 0.003, respectively). CONCLUSIONS: The arthroscopic suture bridge repair technique for rotator cuff tears may be an operative method for which a patient can expect to achieve clinical improvement regardless of the preoperative tear size and the extent of fatty degeneration. The Korean Orthopaedic Association 2010-06 2010-05-04 /pmc/articles/PMC2867195/ /pubmed/20514268 http://dx.doi.org/10.4055/cios.2010.2.2.105 Text en Copyright © 2010 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Yi, Jin Woong Cho, Nam Su Cho, Seung Hyun Rhee, Yong Girl Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title | Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title_full | Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title_fullStr | Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title_full_unstemmed | Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title_short | Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear |
title_sort | arthroscopic suture bridge repair technique for full thickness rotator cuff tear |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2867195/ https://www.ncbi.nlm.nih.gov/pubmed/20514268 http://dx.doi.org/10.4055/cios.2010.2.2.105 |
work_keys_str_mv | AT yijinwoong arthroscopicsuturebridgerepairtechniqueforfullthicknessrotatorcufftear AT chonamsu arthroscopicsuturebridgerepairtechniqueforfullthicknessrotatorcufftear AT choseunghyun arthroscopicsuturebridgerepairtechniqueforfullthicknessrotatorcufftear AT rheeyonggirl arthroscopicsuturebridgerepairtechniqueforfullthicknessrotatorcufftear |