Cargando…
Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis
Volumetric radiofrequency-based intravascular ultrasound (RF–IVUS) data of coronary segments are increasingly used as endpoints in serial trials of novel anti-atherosclerotic therapies. In a relatively time-consuming process, vessel and lumen contours are defined; these contours are first automatica...
Autores principales: | , , , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2868170/ https://www.ncbi.nlm.nih.gov/pubmed/20191323 http://dx.doi.org/10.1007/s10554-010-9599-y |
_version_ | 1782181048509005824 |
---|---|
author | Huisman, Jennifer Hartmann, Marc Mattern, Eline S. K. Mintz, Gary S. Basalus, Mounir W. Z. van Houwelingen, Gert K. Verhorst, Patrick M. J. von Birgelen, Clemens |
author_facet | Huisman, Jennifer Hartmann, Marc Mattern, Eline S. K. Mintz, Gary S. Basalus, Mounir W. Z. van Houwelingen, Gert K. Verhorst, Patrick M. J. von Birgelen, Clemens |
author_sort | Huisman, Jennifer |
collection | PubMed |
description | Volumetric radiofrequency-based intravascular ultrasound (RF–IVUS) data of coronary segments are increasingly used as endpoints in serial trials of novel anti-atherosclerotic therapies. In a relatively time-consuming process, vessel and lumen contours are defined; these contours are first automatically detected, then visually checked, and finally (in most cases) manually edited to generate reliable volumetric data of vessel geometry and plaque composition. Reduction in number of cross-sectional images for volumetric analysis could save analysis time but may also increase measurement variability of volumetric data. To assess whether a 50% reduction in number of frames per segment (every second frame) alters the reproducibility of volumetric measurements, we performed repeated RF–IVUS analyses of 15 coronary segments with mild-to-moderate atherosclerosis (20.2 ± 0.2 mm-long segments with 46 ± 13% plaque burden). Volumes were calculated based on a total of 731 image frames. Reducing the number of cross-sectional image frames for volumetric measurements saved analysis time (38 ± 9 vs. 68 ± 17 min/segment; P < 0.0001) and resulted for only a few parameters in (borderline) significant but mild differences versus measurements based on all frames (fibrous volume, P < 0.05; necrotic-core volume, P = 0.07). Compared to the intra-observer variability, there was a mild increase in measurement variability for most geometrical and compositional volumetric RF–IVUS parameters. In RF–IVUS studies of mild-to-moderate coronary disease, analyzing less image frames saved analysis time, left most volumetric parameters greatly unaffected, and resulted in a no more than mild increase in measurement variability of volumetric data. |
format | Text |
id | pubmed-2868170 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-28681702010-05-24 Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis Huisman, Jennifer Hartmann, Marc Mattern, Eline S. K. Mintz, Gary S. Basalus, Mounir W. Z. van Houwelingen, Gert K. Verhorst, Patrick M. J. von Birgelen, Clemens Int J Cardiovasc Imaging Original Paper Volumetric radiofrequency-based intravascular ultrasound (RF–IVUS) data of coronary segments are increasingly used as endpoints in serial trials of novel anti-atherosclerotic therapies. In a relatively time-consuming process, vessel and lumen contours are defined; these contours are first automatically detected, then visually checked, and finally (in most cases) manually edited to generate reliable volumetric data of vessel geometry and plaque composition. Reduction in number of cross-sectional images for volumetric analysis could save analysis time but may also increase measurement variability of volumetric data. To assess whether a 50% reduction in number of frames per segment (every second frame) alters the reproducibility of volumetric measurements, we performed repeated RF–IVUS analyses of 15 coronary segments with mild-to-moderate atherosclerosis (20.2 ± 0.2 mm-long segments with 46 ± 13% plaque burden). Volumes were calculated based on a total of 731 image frames. Reducing the number of cross-sectional image frames for volumetric measurements saved analysis time (38 ± 9 vs. 68 ± 17 min/segment; P < 0.0001) and resulted for only a few parameters in (borderline) significant but mild differences versus measurements based on all frames (fibrous volume, P < 0.05; necrotic-core volume, P = 0.07). Compared to the intra-observer variability, there was a mild increase in measurement variability for most geometrical and compositional volumetric RF–IVUS parameters. In RF–IVUS studies of mild-to-moderate coronary disease, analyzing less image frames saved analysis time, left most volumetric parameters greatly unaffected, and resulted in a no more than mild increase in measurement variability of volumetric data. Springer Netherlands 2010-02-27 2010 /pmc/articles/PMC2868170/ /pubmed/20191323 http://dx.doi.org/10.1007/s10554-010-9599-y Text en © The Author(s) 2010 https://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. |
spellingShingle | Original Paper Huisman, Jennifer Hartmann, Marc Mattern, Eline S. K. Mintz, Gary S. Basalus, Mounir W. Z. van Houwelingen, Gert K. Verhorst, Patrick M. J. von Birgelen, Clemens Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title | Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title_full | Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title_fullStr | Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title_full_unstemmed | Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title_short | Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
title_sort | impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2868170/ https://www.ncbi.nlm.nih.gov/pubmed/20191323 http://dx.doi.org/10.1007/s10554-010-9599-y |
work_keys_str_mv | AT huismanjennifer impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT hartmannmarc impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT matternelinesk impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT mintzgarys impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT basalusmounirwz impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT vanhouwelingengertk impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT verhorstpatrickmj impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis AT vonbirgelenclemens impactofanalyzinglessimageframespersegmentforradiofrequencybasedvolumetricintravascularultrasoundmeasurementsinmildtomoderatecoronaryatherosclerosis |