Cargando…

Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black

Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance...

Descripción completa

Detalles Bibliográficos
Autores principales: Desai, Sharanya Arcot, Rolston, John D., Guo, Liang, Potter, Steve M.
Formato: Texto
Lenguaje:English
Publicado: Frontiers Research Foundation 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2871717/
https://www.ncbi.nlm.nih.gov/pubmed/20485478
http://dx.doi.org/10.3389/fneng.2010.00005
_version_ 1782181183283527680
author Desai, Sharanya Arcot
Rolston, John D.
Guo, Liang
Potter, Steve M.
author_facet Desai, Sharanya Arcot
Rolston, John D.
Guo, Liang
Potter, Steve M.
author_sort Desai, Sharanya Arcot
collection PubMed
description Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes.
format Text
id pubmed-2871717
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Frontiers Research Foundation
record_format MEDLINE/PubMed
spelling pubmed-28717172010-05-18 Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black Desai, Sharanya Arcot Rolston, John D. Guo, Liang Potter, Steve M. Front Neuroengineering Neuroscience Implantable microelectrode arrays (MEAs) have been a boon for neural stimulation and recording experiments. Commercially available MEAs have high impedances, due to their low surface area and small tip diameters, which are suitable for recording single unit activity. Lowering the electrode impedance, but preserving the small diameter, would provide a number of advantages, including reduced stimulation voltages, reduced stimulation artifacts and improved signal-to-noise ratio. Impedance reductions can be achieved by electroplating the MEAs with platinum (Pt) black, which increases the surface area but has little effect on the physical extent of the electrodes. However, because of the low durability of Pt black plating, this method has not been popular for chronic use. Sonicoplating (i.e. electroplating under ultrasonic agitation) has been shown to improve the durability of Pt black on the base metals of macro-electrodes used for cyclic voltammetry. This method has not previously been characterized for MEAs used in chronic neural implants. We show here that sonicoplating can lower the impedances of microwire multi-electrode arrays (MMEA) by an order of magnitude or more (depending on the time and voltage of electroplating), with better durability compared to pulsed plating or traditional DC methods. We also show the improved stimulation and recording performance that can be achieved in an in vivo implantation study with the sonicoplated low-impedance MMEAs, compared to high-impedance unplated electrodes. Frontiers Research Foundation 2010-05-06 /pmc/articles/PMC2871717/ /pubmed/20485478 http://dx.doi.org/10.3389/fneng.2010.00005 Text en Copyright © 2010 Desai, Rolston, Guo and Potter. http://www.frontiersin.org/licenseagreement This is an open-access article subject to an exclusive license agreement between the authors and the Frontiers Research Foundation, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are credited.
spellingShingle Neuroscience
Desai, Sharanya Arcot
Rolston, John D.
Guo, Liang
Potter, Steve M.
Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title_full Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title_fullStr Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title_full_unstemmed Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title_short Improving Impedance of Implantable Microwire Multi-Electrode Arrays by Ultrasonic Electroplating of Durable Platinum Black
title_sort improving impedance of implantable microwire multi-electrode arrays by ultrasonic electroplating of durable platinum black
topic Neuroscience
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2871717/
https://www.ncbi.nlm.nih.gov/pubmed/20485478
http://dx.doi.org/10.3389/fneng.2010.00005
work_keys_str_mv AT desaisharanyaarcot improvingimpedanceofimplantablemicrowiremultielectrodearraysbyultrasonicelectroplatingofdurableplatinumblack
AT rolstonjohnd improvingimpedanceofimplantablemicrowiremultielectrodearraysbyultrasonicelectroplatingofdurableplatinumblack
AT guoliang improvingimpedanceofimplantablemicrowiremultielectrodearraysbyultrasonicelectroplatingofdurableplatinumblack
AT potterstevem improvingimpedanceofimplantablemicrowiremultielectrodearraysbyultrasonicelectroplatingofdurableplatinumblack