Cargando…
Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment
BACKGROUND: In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial disse...
Autores principales: | , , , , , |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2873555/ https://www.ncbi.nlm.nih.gov/pubmed/20384999 http://dx.doi.org/10.1186/1471-2334-10-92 |
_version_ | 1782181368516575232 |
---|---|
author | Shepherd, Simon J Beggs, Clive B Smith, Caroline F Kerr, Kevin G Noakes, Catherine J Sleigh, P Andrew |
author_facet | Shepherd, Simon J Beggs, Clive B Smith, Caroline F Kerr, Kevin G Noakes, Catherine J Sleigh, P Andrew |
author_sort | Shepherd, Simon J |
collection | PubMed |
description | BACKGROUND: In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial dissemination and deposition has largely been ignored. However, there is clinical evidence that air ions might play an important role in preventing the transmission of Acinetobacter infection. Although the reasons for this are unclear, it is hypothesized that a physical effect may be responsible: the production of air ions may negatively charge items of plastic medical equipment so that they repel, rather than attract, airborne bacteria. By negatively charging both particles in the air and items of plastic equipment, the ionizers minimize electrostatic deposition on these items. In so doing they may help to interrupt the transmission of Acinetobacter infection in certain healthcare settings such as intensive care units. METHODS: A study was undertaken in a mechanically ventilated room under ambient conditions to accurately measure changes in surface potential exhibited by items of plastic medical equipment in the presence of negative air ions. Plastic items were suspended on nylon threads, either in free space or in contact with a table surface, and exposed to negative ions produced by an air ionizer. The charge build-up on the specimens was measured using an electric field mill while the ion concentration in the room air was recorded using a portable ion counter. RESULTS: The results of the study demonstrated that common items of equipment such as ventilator tubes rapidly developed a large negative charge (i.e. generally >-100V) in the presence of a negative air ionizer. While most items of equipment tested behaved in a similar manner to this, one item, a box from a urological collection and monitoring system (the only item made from styrene acrylonitrile), did however develop a positive charge in the presence of the ionizer. CONCLUSION: The findings of the study suggest that the action of negative air ionizers significantly alters the electrostatic landscape of the clinical environment, and that this has the potential to cause any Acinetobacter-bearing particles in the air to be strongly repelled from some plastic surfaces and attracted to others. In so doing, this may prevent critical items of equipment from becoming contaminated with the bacterium. |
format | Text |
id | pubmed-2873555 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2010 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-28735552010-05-20 Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment Shepherd, Simon J Beggs, Clive B Smith, Caroline F Kerr, Kevin G Noakes, Catherine J Sleigh, P Andrew BMC Infect Dis Research Article BACKGROUND: In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial dissemination and deposition has largely been ignored. However, there is clinical evidence that air ions might play an important role in preventing the transmission of Acinetobacter infection. Although the reasons for this are unclear, it is hypothesized that a physical effect may be responsible: the production of air ions may negatively charge items of plastic medical equipment so that they repel, rather than attract, airborne bacteria. By negatively charging both particles in the air and items of plastic equipment, the ionizers minimize electrostatic deposition on these items. In so doing they may help to interrupt the transmission of Acinetobacter infection in certain healthcare settings such as intensive care units. METHODS: A study was undertaken in a mechanically ventilated room under ambient conditions to accurately measure changes in surface potential exhibited by items of plastic medical equipment in the presence of negative air ions. Plastic items were suspended on nylon threads, either in free space or in contact with a table surface, and exposed to negative ions produced by an air ionizer. The charge build-up on the specimens was measured using an electric field mill while the ion concentration in the room air was recorded using a portable ion counter. RESULTS: The results of the study demonstrated that common items of equipment such as ventilator tubes rapidly developed a large negative charge (i.e. generally >-100V) in the presence of a negative air ionizer. While most items of equipment tested behaved in a similar manner to this, one item, a box from a urological collection and monitoring system (the only item made from styrene acrylonitrile), did however develop a positive charge in the presence of the ionizer. CONCLUSION: The findings of the study suggest that the action of negative air ionizers significantly alters the electrostatic landscape of the clinical environment, and that this has the potential to cause any Acinetobacter-bearing particles in the air to be strongly repelled from some plastic surfaces and attracted to others. In so doing, this may prevent critical items of equipment from becoming contaminated with the bacterium. BioMed Central 2010-04-12 /pmc/articles/PMC2873555/ /pubmed/20384999 http://dx.doi.org/10.1186/1471-2334-10-92 Text en Copyright ©2010 Shepherd et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Shepherd, Simon J Beggs, Clive B Smith, Caroline F Kerr, Kevin G Noakes, Catherine J Sleigh, P Andrew Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title | Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title_full | Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title_fullStr | Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title_full_unstemmed | Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title_short | Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
title_sort | effect of negative air ions on the potential for bacterial contamination of plastic medical equipment |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2873555/ https://www.ncbi.nlm.nih.gov/pubmed/20384999 http://dx.doi.org/10.1186/1471-2334-10-92 |
work_keys_str_mv | AT shepherdsimonj effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment AT beggscliveb effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment AT smithcarolinef effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment AT kerrkeving effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment AT noakescatherinej effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment AT sleighpandrew effectofnegativeairionsonthepotentialforbacterialcontaminationofplasticmedicalequipment |