Cargando…
Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients: a randomized, controlled trial
INTRODUCTION: Several studies have shown that goal-directed hemodynamic and fluid optimization may result in improved outcome. However, the methods used were either invasive or had other limitations. The aim of this study was to perform intraoperative goal-directed therapy with a minimally invasive,...
Autores principales: | Mayer, Jochen, Boldt, Joachim, Mengistu, Andinet M, Röhm, Kerstin D, Suttner, Stefan |
---|---|
Formato: | Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2010
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2875533/ https://www.ncbi.nlm.nih.gov/pubmed/20156348 http://dx.doi.org/10.1186/cc8875 |
Ejemplares similares
-
Individualized intraoperative patient optimization using uncalibrated arterial pressure waveform analysis in high-risk patients undergoing major abdominal surgery
por: Mayer, J, et al.
Publicado: (2009) -
Utilisation of structured triglycerides (Structolipid(®)) in surgical ICU patients receiving parenteral nutrition
por: Piper, S, et al.
Publicado: (2006) -
Postconditioning effects following sevoflurane inhalational sedation in the ICU: a pilot study in cardiac surgery patients
por: Röhm, K, et al.
Publicado: (2009) -
MDT Autocalibration using MINUIT
por: Amelung, C
Publicado: (2004) -
Comparison of Goal-Directed Hemodynamic Optimization Using Pulmonary Artery Catheter and Autocalibrated Arterial Pressure Waveform Analysis Vigileo-FloTrac™ System in On-Pump Coronary Artery Bypass Graft Surgery: A Randomized Controlled Studya
por: Hamed, Mohamed Ahmed, et al.
Publicado: (2018)