Cargando…

Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring

This study aims to develop an amperometric glucose biosensor, based on carbon nanotubes material for reverse iontophoresis, fabricated by immobilizing a mixture of glucose oxidase (GOD) and multiwalled carbon nanotubes (MWCNT) epoxy-composite, on a planar screen-printed carbon electrode. MWCNT was e...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Tai-Ping, Shieh, Hsiu-Li, Ching, Congo Tak-Shing, Yao, Yan-Dong, Huang, Su-Hua, Liu, Chia-Ming, Liu, Wei-Hao, Chen, Chung-Yuan
Formato: Texto
Lenguaje:English
Publicado: Dove Medical Press 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2875728/
https://www.ncbi.nlm.nih.gov/pubmed/20517479
_version_ 1782181631762628608
author Sun, Tai-Ping
Shieh, Hsiu-Li
Ching, Congo Tak-Shing
Yao, Yan-Dong
Huang, Su-Hua
Liu, Chia-Ming
Liu, Wei-Hao
Chen, Chung-Yuan
author_facet Sun, Tai-Ping
Shieh, Hsiu-Li
Ching, Congo Tak-Shing
Yao, Yan-Dong
Huang, Su-Hua
Liu, Chia-Ming
Liu, Wei-Hao
Chen, Chung-Yuan
author_sort Sun, Tai-Ping
collection PubMed
description This study aims to develop an amperometric glucose biosensor, based on carbon nanotubes material for reverse iontophoresis, fabricated by immobilizing a mixture of glucose oxidase (GOD) and multiwalled carbon nanotubes (MWCNT) epoxy-composite, on a planar screen-printed carbon electrode. MWCNT was employed to ensure proper incorporation into the epoxy mixture and faster electron transfer between the GOD and the transducer. Results showed this biosensor possesses a low detection potential (+500 mV), good sensitivity (4 μA/mM) and an excellent linear response range (r(2) = 0.999; 0–4 mM) of glucose detection at +500 mV (versus Ag/AgCl). The response time of the biosensor was about 25 s. In addition, the biosensor could be used in conjunction with reverse iontophoresis technique. In an actual evaluation model, an excellent linear relationship (r(2) = 0.986) was found between the glucose concentration of the actual model and the biosensor’s current response. Thus, a glucose biosensor based on carbon nanotube composites and incorporated with reverse iontophoresis function was developed.
format Text
id pubmed-2875728
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-28757282010-06-01 Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring Sun, Tai-Ping Shieh, Hsiu-Li Ching, Congo Tak-Shing Yao, Yan-Dong Huang, Su-Hua Liu, Chia-Ming Liu, Wei-Hao Chen, Chung-Yuan Int J Nanomedicine Original Research This study aims to develop an amperometric glucose biosensor, based on carbon nanotubes material for reverse iontophoresis, fabricated by immobilizing a mixture of glucose oxidase (GOD) and multiwalled carbon nanotubes (MWCNT) epoxy-composite, on a planar screen-printed carbon electrode. MWCNT was employed to ensure proper incorporation into the epoxy mixture and faster electron transfer between the GOD and the transducer. Results showed this biosensor possesses a low detection potential (+500 mV), good sensitivity (4 μA/mM) and an excellent linear response range (r(2) = 0.999; 0–4 mM) of glucose detection at +500 mV (versus Ag/AgCl). The response time of the biosensor was about 25 s. In addition, the biosensor could be used in conjunction with reverse iontophoresis technique. In an actual evaluation model, an excellent linear relationship (r(2) = 0.986) was found between the glucose concentration of the actual model and the biosensor’s current response. Thus, a glucose biosensor based on carbon nanotube composites and incorporated with reverse iontophoresis function was developed. Dove Medical Press 2010-05-13 2010 /pmc/articles/PMC2875728/ /pubmed/20517479 Text en © 2010 Sun et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Sun, Tai-Ping
Shieh, Hsiu-Li
Ching, Congo Tak-Shing
Yao, Yan-Dong
Huang, Su-Hua
Liu, Chia-Ming
Liu, Wei-Hao
Chen, Chung-Yuan
Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title_full Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title_fullStr Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title_full_unstemmed Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title_short Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
title_sort carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2875728/
https://www.ncbi.nlm.nih.gov/pubmed/20517479
work_keys_str_mv AT suntaiping carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT shiehhsiuli carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT chingcongotakshing carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT yaoyandong carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT huangsuhua carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT liuchiaming carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT liuweihao carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring
AT chenchungyuan carbonnanotubecompositesforglucosebiosensorincorporatedwithreverseiontophoresisfunctionfornoninvasiveglucosemonitoring