Cargando…

Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a human pathogen, representing an infection control challenge. Conventional MRSA screening takes up to three days, therefore development of rapid detection is essential. Real time-PCR (rt-PCR) is the fastest method fulfilling this tas...

Descripción completa

Detalles Bibliográficos
Autores principales: Kolman, Sara, Arielly, Haya, Paitan, Yossi
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2877054/
https://www.ncbi.nlm.nih.gov/pubmed/20406494
http://dx.doi.org/10.1186/1756-0500-3-110
_version_ 1782181755932901376
author Kolman, Sara
Arielly, Haya
Paitan, Yossi
author_facet Kolman, Sara
Arielly, Haya
Paitan, Yossi
author_sort Kolman, Sara
collection PubMed
description BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a human pathogen, representing an infection control challenge. Conventional MRSA screening takes up to three days, therefore development of rapid detection is essential. Real time-PCR (rt-PCR) is the fastest method fulfilling this task. All currently published or commercially available rt-PCR MRSA assays relay on single or double-locus detection. Double-locus assays are based on simultaneous detection of mecA gene and a S. aureus-specific gene. Such assays cannot be applied on clinical samples, which often contain both coagulase-negative staphylococci (CoNS) and S. aureus, either of which can carry mecA. Single-locus assays are based on detection of the staphylococcal cassette chromosome mec (SCCmec) element and the S. aureus-specific orfX gene, assuming that it is equivalent to mecA detection. FINDINGS: Parallel evaluation of several published single and double-locus rt-PCR MRSA assays of 150 pure culture strains, followed by analysis of 460 swab-derived clinical samples which included standard identification, susceptibility testing, followed by PCR detection of staphylococcal suspected isolates and in-PCR mixed bacterial populations analysis indicated the following findings. Pure cultures analysis indicated that one of the single-locus assay had very high prevalence of false positives (Positive predictive value = 77.8%) and was excluded from further analysis. Analysis of 460 swab-derived samples indicated that the second single-locus assay misidentified 16 out of 219 MRSA's and 13 out of 90 methicillin-sensitive S. aureus's (MSSA) were misidentified as MRSA's. The double-locus detection assay misidentified 55 out of 90 MSSA's. 46 MSSA containing samples were misidentified as MRSA and 9 as other than S. aureus ending with low positive predicted value (<85%) and very low specificity (<62%). CONCLUSION: The results indicate that high prevalence of false-positive and false-negative reactions occurs in such assays.
format Text
id pubmed-2877054
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-28770542010-05-27 Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance Kolman, Sara Arielly, Haya Paitan, Yossi BMC Res Notes Short Report BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA) is a human pathogen, representing an infection control challenge. Conventional MRSA screening takes up to three days, therefore development of rapid detection is essential. Real time-PCR (rt-PCR) is the fastest method fulfilling this task. All currently published or commercially available rt-PCR MRSA assays relay on single or double-locus detection. Double-locus assays are based on simultaneous detection of mecA gene and a S. aureus-specific gene. Such assays cannot be applied on clinical samples, which often contain both coagulase-negative staphylococci (CoNS) and S. aureus, either of which can carry mecA. Single-locus assays are based on detection of the staphylococcal cassette chromosome mec (SCCmec) element and the S. aureus-specific orfX gene, assuming that it is equivalent to mecA detection. FINDINGS: Parallel evaluation of several published single and double-locus rt-PCR MRSA assays of 150 pure culture strains, followed by analysis of 460 swab-derived clinical samples which included standard identification, susceptibility testing, followed by PCR detection of staphylococcal suspected isolates and in-PCR mixed bacterial populations analysis indicated the following findings. Pure cultures analysis indicated that one of the single-locus assay had very high prevalence of false positives (Positive predictive value = 77.8%) and was excluded from further analysis. Analysis of 460 swab-derived samples indicated that the second single-locus assay misidentified 16 out of 219 MRSA's and 13 out of 90 methicillin-sensitive S. aureus's (MSSA) were misidentified as MRSA's. The double-locus detection assay misidentified 55 out of 90 MSSA's. 46 MSSA containing samples were misidentified as MRSA and 9 as other than S. aureus ending with low positive predicted value (<85%) and very low specificity (<62%). CONCLUSION: The results indicate that high prevalence of false-positive and false-negative reactions occurs in such assays. BioMed Central 2010-04-21 /pmc/articles/PMC2877054/ /pubmed/20406494 http://dx.doi.org/10.1186/1756-0500-3-110 Text en Copyright ©2010 Paitan et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Report
Kolman, Sara
Arielly, Haya
Paitan, Yossi
Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title_full Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title_fullStr Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title_full_unstemmed Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title_short Evaluation of single and double-locus real-time PCR assays for methicillin-resistant Staphylococcus aureus (MRSA) surveillance
title_sort evaluation of single and double-locus real-time pcr assays for methicillin-resistant staphylococcus aureus (mrsa) surveillance
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2877054/
https://www.ncbi.nlm.nih.gov/pubmed/20406494
http://dx.doi.org/10.1186/1756-0500-3-110
work_keys_str_mv AT kolmansara evaluationofsingleanddoublelocusrealtimepcrassaysformethicillinresistantstaphylococcusaureusmrsasurveillance
AT ariellyhaya evaluationofsingleanddoublelocusrealtimepcrassaysformethicillinresistantstaphylococcusaureusmrsasurveillance
AT paitanyossi evaluationofsingleanddoublelocusrealtimepcrassaysformethicillinresistantstaphylococcusaureusmrsasurveillance